Cone beam CT: a current overview of devices

被引:104
作者
Nemtoi, A. [1 ]
Czink, C. [2 ]
Haba, D. [1 ]
Gahleitner, A. [3 ]
机构
[1] Gr T Popa Univ Med & Pharm, Dept Gen & Dent Radiol, Iasi 700115, Romania
[2] Med Univ Vienna, Bernhard Gottlieb Univ Clin Dent, Dept Radiol, Vienna, Austria
[3] Med Univ Vienna, Dept Radiol, Vienna, Austria
关键词
radiology; three-dimensional imaging; cone beam computed tomography; tomography scanners; COMPUTED-TOMOGRAPHY; IMAGE QUALITY; MAXILLOFACIAL REGION; CBCT; PROTECTION; GUIDANCE;
D O I
10.1259/dmfr.20120443
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The purpose of this study was to review and compare the properties of all the available cone beam CT (CBCT) devices offered on the market, while focusing especially on Europe. In this study, we included all the different commonly used CBCT devices currently available on the European market. Information about the properties of each device was obtained from the manufacturers' official available data, which was later confirmed by their representatives in cases where it was necessary. The main features of a total of 47 CBCT devices that are currently marketed by 20 companies were presented, compared and discussed in this study. All these CBCT devices differ in specific properties according to the companies that produce them. The summarized technical data from a large number of CBCT devices currently on the market offer a wide range of imaging possibilities in the oral and maxillofacial region.
引用
收藏
页数:8
相关论文
共 30 条
[1]   Development of a compact computed tomographic apparatus for dental use [J].
Arai, Y ;
Tammisalo, E ;
Iwai, K ;
Hashimoto, K ;
Shinoda, K .
DENTOMAXILLOFACIAL RADIOLOGY, 1999, 28 (04) :245-248
[2]  
Barghan Sevin, 2012, Tex Dent J, V129, P289
[3]   Cone-beam computed tomography: a new low dose, high resolution imaging technique of the wrist, presentation of three cases with technique [J].
De Cock, Jens ;
Mermuys, Koen ;
Goubau, Jean ;
Van Petegem, Simon ;
Houthoofd, Brecht ;
Casselman, Jan W. .
SKELETAL RADIOLOGY, 2012, 41 (01) :93-96
[4]   Cone-beam computerized tomography (CBCT) imaging of the oral and maxillofacial region: A systematic review of the literature [J].
De Vos, W. ;
Casselman, J. ;
Swennen, G. R. J. .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2009, 38 (06) :609-625
[5]   Low-dose CT of the paranasal sinuses with eye lens protection: effect on image quality and radiation dose [J].
Hein, E ;
Rogalla, P ;
Klingebiel, R ;
Hamm, B .
EUROPEAN RADIOLOGY, 2002, 12 (07) :1693-1696
[6]   Three-dimensional cone beam computerized tomography in orthodontics [J].
Kau, C. H. ;
Richmond, S. ;
Palomo, J. M. ;
Hans, M. G. .
JOURNAL OF ORTHODONTICS, 2005, 32 (04) :282-293
[7]   Cone-beam computed tomography of the maxillofacial region - an update [J].
Kau, Chung How ;
Bozic, Marko ;
English, Jeryl ;
Lee, Robert ;
Bussa, Harry ;
Ellis, Randy K. .
INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2009, 5 (04) :366-380
[8]   Cone beam imaging: is this the ultimate imaging modality? [J].
Koong, Bernard .
CLINICAL ORAL IMPLANTS RESEARCH, 2010, 21 (11) :1201-1208
[9]   A comparative evaluation of Cone Beam Computed Tomography (CBCT) and Multi-Slice CT (MSCT) Part I. On subjective image quality [J].
Liang, Xin ;
Jacobs, Reinhilde ;
Hassan, Bassam ;
Li, Limin ;
Pauwels, Ruben ;
Corpas, Livia ;
Souza, Paulo Couto ;
Martens, Wendy ;
Shahbazian, Maryam ;
Alonso, Arie ;
Lambrichts, Ivo .
EUROPEAN JOURNAL OF RADIOLOGY, 2010, 75 (02) :265-269
[10]   Influence of Voxel Size in the Diagnostic Ability of Cone Beam Tomography to Evaluate Simulated External Root Resorption [J].
Liedke, Gabriela Salatino ;
Dias da Silveira, Heloisa Emilia ;
Dias da Silveira, Heraldo Luis ;
Dutra, Vinicius ;
Poli de Figueiredo, Jose Antonio .
JOURNAL OF ENDODONTICS, 2009, 35 (02) :233-235