Flexural strength of nano-hybrid resin composite as a function of light attenuation distance and specimen dimension

被引:11
作者
El-Askary, Farid Sabry [1 ]
Botros, Sara Adel [2 ]
Nassif, Mohamed Salah Abdelaziz [3 ]
Ozcan, Mutlu [4 ]
机构
[1] Ain Shams Univ, Dept Operat Dent, Fac Dent, Cairo, Egypt
[2] British Univ Egypt, Dept Operat Dent, Fac Dent, Cairo, Egypt
[3] Ain Shams Univ, Dent Biomat Dept, Fac Dent, Cairo, Egypt
[4] Univ Zurich, Dent Mat Unit, Ctr Dent & Oral Med, Clin Fixed & Removable Prosthodont & Dent Mat Sci, Zurich, Switzerland
关键词
Flexural strength; ISO; 4049; photo-polymerization; resin composite; MECHANICAL-PROPERTIES; CURING UNITS; CONVERSION; CURE; INTENSITY; MICROHARDNESS; RELIABILITY; SURFACE; DENTIN; DEPTH;
D O I
10.1080/01694243.2016.1221251
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
This study evaluated ascending order of light attenuation distance (0, 2, 4, 8 mm) and specimen dimensions (2 x 2 x 10, 2 x 2 x 12, 2 x 2 x 15 mm(3)) differing from requirements of ISO 4049 (2 x 2 x 25 mm(3)) on the flexural strength of nano-hybrid resin composite. Specimens (N = 160) were prepared accordingly and randomly assigned into groups for the factors studied. Specimens were photo-polymerized from increased distances through 1, 2, 3 and 5 overlapping cycles depending on the specimen length after which they were subjected to three-point bending test (0.5 mm/min). Data were statistically analysed using one-way, two-way ANOVA and Tukey's HSD post hoc tests (a = 0.05). Two-parameter Weibull modulus, scale (m) and shape ((0)) were calculated. Both light attenuation distance (p < 0.001) and specimen dimensions (p < 0.001) significantly affected the results. Regardless of the specimen dimensions, 0.2 mm polymerization distance resulted in significantly higher mean flexural strength compared to 4 and 8 mm. Polymerization distance did not significantly affect the mean flexural strength of specimens prepared according to ISO norms (p > 0.05). Weibull distribution presented the highest shape (m) for 10-8 mm (24.65), 12-4 mm (14.54), 15-2 mm (12.32), 25-2 mm (17.56), length-light distance combinations. Specimen dimensions prepared in accordance with ISO 4049 do not allow for comparison of the effect of light attenuation distance on the flexural strength of resin composite tested.
引用
收藏
页码:520 / 529
页数:10
相关论文
共 38 条
  • [1] Anusavice KJ., 1996, Phillips'science of dental materials, V10th, P33
  • [2] Variation of depth of cure and intensity with distance using LED curing lights
    Aravamudhan, Krishna
    Rakowski, Duane
    Fan, P. L.
    [J]. DENTAL MATERIALS, 2006, 22 (11) : 988 - 994
  • [3] Long-term flexural strength of three direct aesthetic restorative materials
    Azillah, MA
    Anstice, HM
    Pearson, GJ
    [J]. JOURNAL OF DENTISTRY, 1998, 26 (02) : 177 - 182
  • [4] Bouschlicher MR, 2004, OPER DENT, V29, P698
  • [5] Cabrera CAG, 2011, DENT PRESS J ORTHOD, V16, P111
  • [6] Caldas DBM, 2003, OPER DENT, V28, P315
  • [7] Influence of radiant exposure on contraction stress, degree of conversion and mechanical properties of resin composites
    Calheiros, Fernanda C.
    Kawano, Yoshio
    Stansbury, Jeffrey W.
    Braga, Roberto R.
    [J]. DENTAL MATERIALS, 2006, 22 (09) : 799 - 803
  • [8] Relationship between the degree of conversion, solubility and salivary sorption of a hybrid and a nanofilled resin composite: Influence of the light-activation mode
    da Silva, Eduardo Moreira
    Almeida, Giselle Soares
    Poskus, Laiza Tatiana
    Antunes Guimaraes, Jos Guilherme
    [J]. JOURNAL OF APPLIED ORAL SCIENCE, 2008, 16 (02) : 161 - 166
  • [9] DARVELL BW, 1990, J MATER SCI, V25, P757
  • [10] Dionysopoulos P., 1994, Odontostomatologike Proodos, V48, P19