Evaluation of four pretreatment procedures for MALDI-TOF MS yeast identification in the routine clinical laboratory

被引:72
作者
Cassagne, Carole [1 ]
Cella, Anne-Laure [1 ]
Suchon, Pierre [1 ]
Normand, Anne-Cecile [1 ]
Ranque, Stephane [1 ]
Piarroux, Renaud [1 ]
机构
[1] Univ Mediterranee, CHU Timone, Lab Parasitol Mycol, Marseille, France
关键词
spectrometry; mass; matrix-assisted laser desorption-ionization; clinical laboratory techniques; fungi; FLIGHT MASS-SPECTROMETRY; DESORPTION IONIZATION-TIME; MICROBIOLOGY; EPIDEMIOLOGY; SURVEILLANCE;
D O I
10.3109/13693786.2012.720720
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
MALDI-TOF MS-based yeast identification requires a pretreatment step for which four are described in the literature, i.e., direct smear, fast formic acid and two complete formic acid/acetonitrile extractions. In this study we compared the impact of these procedures on the performance of MALDI-TOF MS-based yeast identification of samples from colonies grown on Sabouraud or chromogenic media. A total of 103 yeast isolates recovered from clinical samples were identified in parallel using the four pretreatment procedures. The proportions of both correct identifications (regardless of LogScore values) and of reliable identifications (i.e., correct identifications with a LogScore >= 2, as recommended by the manufacturer) obtained with the four techniques were compared. Even if the proportion of correct identifications exceeded 85% independent of the pretreatment procedure, results obtained with complete formic acid/acetonitril extractions of colonies grown on Sabouraud media were significantly superior to those with smear and fast formic acid extraction procedures. If one considers only reliable identifications, then both smear and fast formic acid extraction procedures yielded lower (<40%) correct identification rates than the use of the two complete extraction procedures (>77%) of portions of colonies on both Sabouraud and chromogenic media. The data would indicate that the direct smear and fast formic acid procedures cannot be recommended due to the LogScore values which were continually below those recommended by the manufacturer for biological validation. Thus, complete extraction methods are better suited for MALDI-TOF MS-based yeast identification in the clinical laboratory setting although they are more labor-intensive.
引用
收藏
页码:371 / 377
页数:7
相关论文
共 18 条
[1]   Improved clinical laboratory identification of human pathogenic yeasts by matrix-assisted laser desorption ionization time-of-flight mass spectrometry [J].
Bader, O. ;
Weig, M. ;
Taverne-Ghadwal, L. ;
Lugert, R. ;
Gross, U. ;
Kuhns, M. .
CLINICAL MICROBIOLOGY AND INFECTION, 2011, 17 (09) :1359-1365
[2]  
Bille E, 2011, CLIN MICROBIOL INFEC, DOI [10.1111/j.1469-0691 2011.03688.x, DOI 10.1111/J.1469-0691.2011.03688.X.[]
[3]   Mould Routine Identification in the Clinical Laboratory by Matrix-Assisted Laser Desorption Ionization Time-Of-Flight Mass Spectrometry [J].
Cassagne, Carole ;
Ranque, Stephane ;
Normand, Anne-Cecile ;
Fourquet, Patrick ;
Thiebault, Sandrine ;
Planard, Chantal ;
Hendrickx, Marijke ;
Piarroux, Renaud .
PLOS ONE, 2011, 6 (12)
[4]   Applications of MALDI-TOF mass spectrometry in clinical diagnostic microbiology [J].
Croxatto, Antony ;
Prod'hom, Guy ;
Greub, Gilbert .
FEMS MICROBIOLOGY REVIEWS, 2012, 36 (02) :380-407
[5]  
de Hoog G S, 2007, Stud Mycol, V58, P219, DOI 10.3114/sim.2007.58.08
[6]   Performance and Cost Analysis of Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry for Routine Identification of Yeast [J].
Dhiman, Neelam ;
Hall, Leslie ;
Wohlfiel, Sherri L. ;
Buckwalter, Seanne P. ;
Wengenack, Nancy L. .
JOURNAL OF CLINICAL MICROBIOLOGY, 2011, 49 (04) :1614-1616
[7]   Yeast identification in the clinical microbiology accepted 15 August 2000 laboratory: phenotypical methods [J].
Freydiere, AM ;
Guinet, R ;
Boiron, P .
MEDICAL MYCOLOGY, 2001, 39 (01) :9-33
[8]   Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry for Fast and Reliable Identification of Clinical Yeast Isolates [J].
Marklein, G. ;
Josten, M. ;
Klanke, U. ;
Mueller, E. ;
Horre, R. ;
Maier, T. ;
Wenzel, T. ;
Kostrzewa, M. ;
Bierbaum, G. ;
Hoerauf, A. ;
Sahl, H. -G. .
JOURNAL OF CLINICAL MICROBIOLOGY, 2009, 47 (09) :2912-2917
[9]   Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry in clinical chemistry [J].
Marvin, LF ;
Roberts, MA ;
Fay, LB .
CLINICA CHIMICA ACTA, 2003, 337 (1-2) :11-21
[10]   Rapid Identification of Cryptococcus neoformans and Cryptococcus gattii by Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry [J].
McTaggart, Lisa R. ;
Lei, Eric ;
Richardson, Susan E. ;
Hoang, Linda ;
Fothergill, Annette ;
Zhang, Sean X. .
JOURNAL OF CLINICAL MICROBIOLOGY, 2011, 49 (08) :3050-3053