Factors related to quality of ambulatory blood pressure monitoring in a pediatric population

被引:30
作者
Lurbe, E
Cremades, B
Rodriguez, C
Torro, MI
Alvarez, V
Redon, J
机构
[1] Univ Valencia, Gen Hosp, Dept Pediat, Pediat Nephrol Unit, Valencia 46014, Spain
[2] Univ Valencia, Hosp Clin, Hypertens Clin, Valencia 46014, Spain
关键词
ambulatory blood pressure; children; blood pressure measurement; pulse pressure;
D O I
10.1016/S0895-7061(99)00076-X
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
To assess the factors related to the quality of ambulatory blood pressure monitoring in a pediatric population, we performed 24-h ambulatory blood pressure monitorings on 333 unselected children aged 3 to 18 years using a Spacelabs 90207 monitor. For each individual, the percentages of valid measurements (ratio between valid and total number of measurements, 76.4% +/- 15.6%) and of successful measurements (percentage of valid preset measurements, 89.8% +/- 11.5%) were calculated, Two hundred eighty-one (84.1%) monitorings had a successful measurement rate of > 80%. Two hundred thirteen (64%) were of excellent quality, as defined by the percentage of successful measurements being higher than or equal to 90%. Age (P < .0001) and 24-h systolic blood pressure (P < .04) were positively and independently associated tin multiple regression analysis) to the percentage of successful measurements, accounting for 8% of the variance. Furthermore, a significant negative correlation between causal pulse pressure and the number of erroneous measurements was observed (r = -0.18, P < .01). This study has shown that in a pediatric population the quality of the monitoring depends only in part on age and ambulatory systolic blood pressure values when an oscillometric device is used. The results have demonstrated the important role pulse pressure amplitude plays when accounting for the number of erroneous measurements. Am J Hypertens 1999;12:929-933 (C) 1999 American Journal of Hypertension, Ltd.
引用
收藏
页码:929 / 933
页数:5
相关论文
共 15 条
  • [1] Hypertension in young patients after renal transplantation - Ambulatory blood pressure monitoring versus casual blood pressure
    Calzolari, A
    Giordano, U
    Matteucci, MC
    Pastore, E
    Turchetta, A
    Rizzoni, G
    Alpert, B
    [J]. AMERICAN JOURNAL OF HYPERTENSION, 1998, 11 (04) : 497 - 501
  • [2] CATES EM, 1990, J AMBULATORY MONITOR, V3, P149
  • [3] PROGNOSTIC VALUE OF 24-HOUR BLOOD-PRESSURE VARIABILITY
    FRATTOLA, A
    PARATI, G
    CUSPIDI, C
    ALBINI, F
    MANCIA, G
    [J]. JOURNAL OF HYPERTENSION, 1993, 11 (10) : 1133 - 1137
  • [4] ALTERED BLOOD-PRESSURE DURING SLEEP IN NORMOTENSIVE SUBJECTS WITH TYPE-I DIABETES
    LURBE, A
    REDON, J
    PASCUAL, JM
    TACONS, J
    ALVAREZ, V
    BATLLE, DC
    [J]. HYPERTENSION, 1993, 21 (02) : 227 - 235
  • [5] Lurbe E, 1996, J HYPERTENS, V14, P41
  • [6] The impact of obesity and body fat distribution on ambulatory blood pressure in children and adolescents
    Lurbe, E
    Alvarez, V
    Line, YL
    Tacons, J
    Cooper, R
    Cremades, B
    Torro, I
    Redón, J
    [J]. AMERICAN JOURNAL OF HYPERTENSION, 1998, 11 (04) : 418 - 424
  • [7] LURBE E, 1994, J HYPERTENS, V12, P1417
  • [8] LURBE E, 1993, J HYPERTENS S5, V11, P288
  • [9] MANCIA G, 1985, J HYPERTENS, V3, pS5
  • [10] PERLOFF D, 1989, J HYPERTENS S3, V7, P3