Pictorial review: Electron beam computed tomography and multislice spiral computed tomography for cardiac imaging

被引:14
作者
Lembcke, A
Hein, PA
Dohmen, PM
Klessen, C
Wiese, TH
Hoffmann, U
Hamm, B
Enzweiler, CNH
机构
[1] Free Univ Berlin, Charite Univ Med Berlin, Dept Radiol, D-1000 Berlin, Germany
[2] Humboldt Univ, Berlin, Germany
[3] Augusta Hosp, Dept Radiol, Bochum, Germany
[4] Massachusetts Gen Hosp, Dept Radiol, Boston, MA 02114 USA
[5] Harvard Univ, Sch Med, Boston, MA USA
关键词
computed tomography; coronary angiography; coronary calcium scoring; cardiac function analysis; image quality;
D O I
10.1016/j.ejrad.2005.12.021
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Electron beam computed tomography (EBCT) revolutionized cardiac imaging by combining a constant high temporal resolution with prospective ECG triggering. For years, EBCT was the primary technique for some non-invasive diagnostic cardiac procedures such as calcium scoring and non-invasive angiography of the coronary arteries. Multislice spiral computed tomography (MSCT) on the other hand significantly advanced cardiac imaging through high volume coverage, improved spatial resolution and retrospective ECG gating. This pictorial review will illustrate the basic differences between both modalities with special emphasis to their image quality. Several experimental and clinical examples demonstrate the strengths and limitations of both imaging modalities in an intraindividual comparison for a broad range of diagnostic applications such as coronary artery calcium scoring, coronary angiography including stent visualization as well as functional assessment of the cardiac ventricles and valves. In general, our examples indicate that EBCT suffers from a number of shortcomings such as limited spatial resolution and a low contrast-to-noise ratio. Thus, EBCT should now only be used in selected cases where a constant high temporal resolution is a crucial issue, such as dynamic (cine) imaging. Due to isotropic submillimeter spatial resolution and retrospective data selection MSCT seems to be the non-invasive method of choice for cardiac imaging in general, and for assessment of the coronary arteries in particular. However, technical developments are still needed to further improve the temporal resolution in MSCT and to reduce the substantial radiation exposure. (C) 2006 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:356 / 367
页数:12
相关论文
共 21 条
[1]   Detection of coronary artery stenoses using multi-detector CT with 16 x 0.75 collimation and 375 ms rotation [J].
Achenbach, S ;
Ropers, D ;
Pohle, FK ;
Raaz, D ;
von Erffa, J ;
Yilmaz, A ;
Muschiol, G ;
Daniel, WG .
EUROPEAN HEART JOURNAL, 2005, 26 (19) :1978-1986
[2]   Value of electron-beam computed tomography for the noninvasive detection of high-grade coronary-artery stenoses and occlusions [J].
Achenbach, S ;
Moshage, W ;
Ropers, D ;
Nossen, J ;
Daniel, WG .
NEW ENGLAND JOURNAL OF MEDICINE, 1998, 339 (27) :1964-1971
[3]  
Enzweiler CNH, 2004, ROFO-FORTSCHR RONTG, V176, P27
[4]   Effect of acquisition technique on radiation dose and image quality in multidetector row computed tomography coronary angiography with submillimeter collimation [J].
Gerber, TC ;
Stratmann, BP ;
Kuzo, RS ;
Kantor, B ;
Morin, RL .
INVESTIGATIVE RADIOLOGY, 2005, 40 (08) :556-563
[5]   Noninvasive coronary angiography with 16-detector row CT: Effect of heart rate [J].
Hoffmann, MHK ;
Shi, HS ;
Manzke, R ;
Schmid, FT ;
De Vries, L ;
Grass, M ;
Brambs, HR ;
Aschoff, AJ .
RADIOLOGY, 2005, 234 (01) :86-97
[6]   Predictive value of 16-slice multidetector spiral computed tomography to detect significant obstructive coronary artery disease in patients at high risk for coronary artery disease - Patient-versus segment-based analysis [J].
Hoffmann, U ;
Moselewski, F ;
Cury, RC ;
Ferencik, M ;
Jang, IK ;
Diaz, LJ ;
Abbara, S ;
Brady, TJ ;
Achenbach, S .
CIRCULATION, 2004, 110 (17) :2638-2643
[7]   Radiation exposure during cardiac CT: Effective doses at multi-detector row CT and electron-beam CT [J].
Hunold, P ;
Vogt, FM ;
Schmermund, A ;
Debatin, JF ;
Kerkhoff, G ;
Budde, T ;
Erbel, R ;
Ewen, K ;
Barkhausen, J .
RADIOLOGY, 2003, 226 (01) :145-152
[8]   Determination of coronary calcium with Multi-slice Spiral computed tomography: a comparative study with electron-beam CT [J].
Knez, A ;
Becker, C ;
Becker, A ;
Leber, A ;
White, C ;
Reiser, M ;
Steinbeck, G .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2002, 18 (04) :295-303
[9]   Quantification of functional mitral valve regurgitation in patients with congestive heart failure: Comparison of electron-beam computed tomography with cardiac catheterization [J].
Lembcke, A ;
Borges, AC ;
Dohmen, PM ;
Hoffmann, U ;
Hermann, KGA ;
Kroencke, TJ ;
Fischer, T ;
Hamm, B ;
Enzweiler, CNH .
INVESTIGATIVE RADIOLOGY, 2004, 39 (12) :728-739
[10]   Image quality of noninvasive coronary angiography using multislice spiral computed tomography and electron-beam computed tomography -: Intraindividual comparison in an animal model [J].
Lembcke, A ;
Wiese, TH ;
Schnorr, J ;
Wagner, S ;
Mews, J ;
Kroencke, TJ ;
Enzweiler, CNH ;
Hamm, B ;
Taupitz, M .