Gradient Elution Moving Boundary Electrophoresis with Field-Amplified Continuous Sample Injection

被引:10
|
作者
Sikorsky, Alison A. [1 ,2 ]
Fourkas, John T. [1 ,3 ,4 ]
Ross, David [2 ]
机构
[1] Univ Maryland, Dept Chem & Biochem, College Pk, MD 20742 USA
[2] NIST, Mat Measurement Lab, Gaithersburg, MD 20878 USA
[3] Univ Maryland, Inst Phys Sci & Technol, Maryland NanoCtr, College Pk, MD 20742 USA
[4] Univ Maryland, Ctr Nanophys & Adv Mat, College Pk, MD 20742 USA
关键词
CAPILLARY ARRAY ELECTROPHORESIS; CONTACTLESS CONDUCTIVITY DETECTION; CHANNEL CURRENT DETECTION; LARGE-VOLUME STACKING; ZONE-ELECTROPHORESIS; SENSITIVITY; MICROCHIPS; ELECTROCHROMATOGRAPHY; SYSTEMS; ENRICHMENT;
D O I
10.1021/ac500242a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The integration of simple and robust device components required for the successful adaptation of many analytical methods to multiplexed and field-portable devices often has negative effects on detection sensitivity, such as in the optical detection components in a capillary electrophoresis (CE) system. One of the simplest methods to improve sensitivity in the CE field is known as sample stacking. This method involves preparing the sample in a buffer with a different concentration (and conductivity) than that of the run buffer so that when an electric field is applied the analyte concentration is increased at the boundary between the two different buffer concentrations. Here, we describe a method in which the sample is prepared in a buffer at a lower concentration than the run buffer coupled with a recently described counterflow electrophoresis method, gradient elution moving boundary electrophoresis (GEMBE), with channel current detection. Because of the continuous sample introduction with GEMBE, we refer to the method as field-amplified continuous sample injection (FACSI). This method achieves a significantly greater signal enhancement than expected for sample stacking. For example, we achieve signal enhancement of 110x with a conductivity ratio of 8.21, and using the detection of arsenate in drinking water as a model system, we have achieved a limit of detection (LOD) improvement of approximately 60x (LODs with and without FACSI are 200 nmol/L and 12 mu mol/L, respectively) with a conductivity ratio of approximately 5.93.
引用
收藏
页码:3625 / 3632
页数:8
相关论文
共 50 条
  • [1] Determination of Ephedrine and Pseudoephedrine by Field-Amplified Sample Injection Capillary Electrophoresis
    Deng, Dongli
    Deng, Hao
    Zhang, Lichun
    Su, Yingying
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2014, 52 (04) : 357 - 362
  • [2] Temperature gradient focusing with field-amplified continuous sample injection for dual-stage analyte enrichment and separation
    Munson, Matthew S.
    Danger, Gregoire
    Shackman, Jonathan G.
    Ross, David
    ANALYTICAL CHEMISTRY, 2007, 79 (16) : 6201 - 6207
  • [3] Combining field-amplified sample stacking with moving reaction boundary electrophoresis on a paper chip for the preconcentration and separation of metal ions
    Ouyang, Liangfei
    Liu, Qian
    Liang, Heng
    JOURNAL OF SEPARATION SCIENCE, 2017, 40 (03) : 789 - 797
  • [4] Determination of chloroacetic acids in water by capillary zone electrophoresis with field-amplified sample injection
    Zhang, Songsong
    Wu, Dandan
    Zhu, Jinhua
    Liu, Xiuhua
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2016, 39 (02) : 59 - 64
  • [5] Sample stacking using field-amplified sample injection in capillary zone electrophoresis in the analysis of phenolic compounds
    Martinez, D
    Borrull, F
    Calull, M
    JOURNAL OF CHROMATOGRAPHY A, 1997, 788 (1-2) : 185 - 193
  • [6] MATHEMATICAL-MODELING OF FIELD-AMPLIFIED SAMPLE INJECTION IN HIGH-PERFORMANCE CAPILLARY ELECTROPHORESIS
    CHIEN, RL
    ANALYTICAL CHEMISTRY, 1991, 63 (24) : 2866 - 2869
  • [7] Highly sensitive chemiluminescence detection of copper(II) in capillary electrophoresis with field-amplified sample injection
    Liu, YM
    Cheng, JK
    ELECTROPHORESIS, 2002, 23 (04) : 556 - 558
  • [8] On-line sample preconcentration using field-amplified stacking injection in microchip capillary electrophoresis
    Gong, Maojun
    Wehmeyer, Kenneth R.
    Limbach, Patrick A.
    Arias, Francisco
    Heineman, William R.
    ANALYTICAL CHEMISTRY, 2006, 78 (11) : 3730 - 3737
  • [9] FIELD-AMPLIFIED POLARITY-SWITCHING SAMPLE INJECTION IN HIGH-PERFORMANCE CAPILLARY ELECTROPHORESIS
    CHIEN, RL
    BURGI, DS
    JOURNAL OF CHROMATOGRAPHY, 1991, 559 (1-2): : 153 - 161
  • [10] Optimization of field-amplified sample injection for analysis of peptides by capillary electrophoresis-mass spectrometry
    Yang, Yuanzhong
    Boysen, Reinhard I.
    Hearn, Milton T. W.
    ANALYTICAL CHEMISTRY, 2006, 78 (14) : 4752 - 4758