Safety of 20-Gauge Transconjunctival Sutureless Vitrectomy

被引:1
作者
Papaefthymiou, Ioannis [1 ]
Petropoulos, Ioannis K. [1 ]
Mangioris, George [1 ]
Mendrinos, Efstratios [1 ]
Pournaras, Constantin J. [1 ]
机构
[1] Univ Geneva, Dept Ophthalmol, Geneva, Switzerland
关键词
20-gauge transconjunctival sutureless vitrectomy; Safety; Sclerotomies; PARS-PLANA VITRECTOMY; CORNEAL TOPOGRAPHIC CHANGES; 25-GAUGE VITRECTOMY; ULTRASOUND BIOMICROSCOPY; POSTOPERATIVE HYPOTONY; INDUCED ASTIGMATISM; INITIAL-EXPERIENCE; AFFER; 25-GAUGE; 23-GAUGE; OUTCOMES;
D O I
10.1159/000346393
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To study the safety of 20-gauge transconjunctival sutureless vitrectomy. Methods: Clinical data of patients who underwent 20-gauge transconjunctival sutureless vitrectomy for the first time, for various disorders, were reviewed retrospectively. The main outcome measures were the number of sclerotomies requiring suturing as well as the intra- and postoperative complications. Results: A total of 179 operations were performed. Indications for vitrectomy included 68 idiopathic epiretinal membranes, 26 macular holes, 23 phakic and 16 pseudophakic retinal detachments, and 46 various other, less common etiologies. Of these 179 operations, 166 (93%) were sutureless. Of the 537 sclerotomies created, 25 (5%) received a single transconjunctival-scleral suture. Intraoperative complications included premature dislodging of the cannulas in 2 sclerotomies and an iatrogenic horseshoe tear at 1 sclerotomy site. Postoperative complications comprised transient hypotony in 14 cases, subconjunctival gas in 2 cases, and choroidal effusion in 1 case. No serious complications (such as endophthalmitis) were observed. Conclusion: 20-gauge transconjunctival sutureless vitrectomy can be considered safe, as the intra- and postoperative complications observed are neither numerous nor significant. Sclerotomies appear to be safe and relatively easy to perform, without compromising the advantages of sutureless surgery. Copyright (C) 2013 S. Karger AG, Basel
引用
收藏
页码:207 / 214
页数:8
相关论文
共 70 条
[1]   Early postoperative hypotony affer 25-gauge sutureless, vitrectomy with straight incisions [J].
Acar, Nur ;
Kapran, Ziya ;
Unver, Yaprak Banu ;
Altan, Tugrul ;
Ozdogan, Sezin .
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2008, 28 (04) :545-552
[2]   Transconjunctival Sutureless 25-Gauge Versus 20-Gauge Standard Vitrectomy: Correlation Between Corneal Topography and Ultrasound Biomicroscopy Measurements of Sclerotomy Sites [J].
Avitabile, Teresio ;
Castiglione, Francesco ;
Bonfiglio, Vincenza ;
Castiglione, Filippo .
CORNEA, 2010, 29 (01) :19-25
[3]   Comparison of clear corneal phacoemulsification combined with 25-gauge transconjunctival a sutureless vitrectomy and standard 20-gauge vitrectomy for patients with cataract and vitreoretinal diseases [J].
Chang, CJ ;
Chang, YH ;
Chiang, SY ;
Lin, LT .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (06) :1198-1207
[4]   Sutureless Vitrectomy Incision Architecture in the Immediate Postoperative Period Evaluated In Vivo Using Optical Coherence Tomography [J].
Chen, Ding ;
Lian, Yan ;
Cui, Lele ;
Lu, Fan ;
Ke, Zhisheng ;
Song, Zongming .
OPHTHALMOLOGY, 2010, 117 (10) :2003-2009
[5]   The incidence of endophthalmitis following transconjunctival sutureless 25-vs 20-gauge vitrectomy [J].
Chen, J. K. ;
Khurana, R. N. ;
Nguyen, Q. D. ;
Do, D. V. .
EYE, 2009, 23 (04) :780-784
[6]  
CLEASBY GW, 1979, OPHTHALMOLOGY, V86, P1973
[7]   ENDOPHTHALMITIS AFTER PARS-PLANA VITRECTOMY [J].
COHEN, SM ;
FLYNN, HW ;
MURRAY, TG ;
SMIDDY, WE ;
AVINS, LR ;
BLODI, CF ;
CHANG, S ;
ELNER, SG ;
GRIZZARD, WS ;
HAMMER, ME ;
HAN, DP ;
JOHNSON, MW ;
MIELER, WF ;
PACKER, AJ ;
REPPUCCI, VS ;
WEINGEIST, TA .
OPHTHALMOLOGY, 1995, 102 (05) :705-712
[8]   Sutureless transconjunctival 20-gauge vitrectomy [J].
Dassie-Ajdid, J. ;
Mahieu, L. ;
Mathis, V. ;
Arne, J-L. ;
Auriol, S. .
JOURNAL FRANCAIS D OPHTALMOLOGIE, 2011, 34 (10) :729-736
[9]   23-gauge transconjunctival sutureless vitrectomy: A retrospective study of 164 consecutive cases [J].
de Preobrajensky, N. ;
Mrejen, S. ;
Adam, R. ;
Ayello-Scheer, S. ;
Gendron, G. ;
Rodallec, T. ;
Sahel, J. -A. ;
Barale, P. -O. .
JOURNAL FRANCAIS D OPHTALMOLOGIE, 2010, 33 (02) :99-104
[10]   Transconjunctival sutureless 23-gauge vitrectomy [J].
Eckardt, C .
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2005, 25 (02) :208-211