Fast Dynamic Reconstruction Algorithm with Joint Bilateral Filtering for Perfusion C-arm CT

被引:0
作者
Manhart, Michael [1 ]
Kowarschik, Markus [2 ]
Fieselmann, Andreas [1 ,3 ]
Yu Deuerling-Zheng [2 ]
Hornegger, Joachim [1 ,3 ]
机构
[1] Univ Erlangen Nurnberg, Pattern Recognit Lab, Dept Comp Sci, Martensstr 3, D-91058 Erlangen, Germany
[2] Siemens AG, Angiog & Intervent X Ray Syst, Forchheim, Germany
[3] Erlangen Grad Sch Adv Opt Technol SAOT, Erlangen, Germany
来源
2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC) | 2012年
关键词
Perfusion imaging; dynamic reconstruction; C-arm CT; stroke treatment; MODEL;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Tissue perfusion measurement using C-arm angiography systems is a novel technique with potential high benefit for catheter-guided treatment of stroke in the interventional suite. However, perfusion C-arm CT (PCCT) is challenging: the slow C-arm rotation speed only allows measuring samples of contrast time attenuation curves (TACs) every 5 - 6 s if reconstruction algorithms for static data are used. Furthermore, the peaks of the tissue TACs typically lie in a range of 5 - 30 HU, thus perfusion imaging is very sensitive to noise. We present a dynamic, iterative reconstruction (DIR) approach to reconstruct TACs described by a weighted sum of linear spline functions. The optimization problem is solved using an appropriate initialization and a Landweber-based optimization strategy with a modified backprojection step. To reduce noise a novel regularization technique based on joint bilateral filtering (JBF) is introduced. The algorithm is evaluated using simulation data created with a dynamic cylindrical phantom, a realistic digital brain phantom and real measured data from an animal study with a canine stroke model. Results indicate that the DIR algorithm qualitatively and quantitatively improves reconstructed TACs and perfusion maps compared to classical Feldkamp (FDK) reconstruction. For the brain phantom study the Pearson correlation (PC) of the reconstructed cerebral blood flow (CBF) maps to the ground truth increased from 0.82 (FDK) to 0.87 (DIR). For the canine study the PC of the CBF maps to co-registered perfusion CT maps increased from 0.61 (FDK) to 0.73 (DIR).
引用
收藏
页码:2304 / 2311
页数:8
相关论文
共 50 条
  • [31] Dose and image quality for a cone-beam C-arm CT system
    Fahrig, Rebecca
    Dixon, Robert
    Payne, Thomas
    Morin, Richard L.
    Ganguly, Arundhuti
    Strobel, Norbert
    MEDICAL PHYSICS, 2006, 33 (12) : 4541 - 4550
  • [32] Image quality improvements in C-Arm CT (CACT) for liver oncology applications: Preliminary study in rabbits
    Tacher, Vania
    Bhagat, Nikhil
    Rao, Pramod P.
    Lin, Mingde
    Schaefer, Dirk
    Noordhoek, Niels
    Eshuis, Peter
    Radaelli, Alessandro
    Liapi, Eleni
    Grass, Michael
    Geschwind, Jean-Francois
    MINIMALLY INVASIVE THERAPY & ALLIED TECHNOLOGIES, 2013, 22 (05) : 297 - 303
  • [33] Image Quality Evaluation for a Robot-Driven C-Arm CT System
    Prell, D.
    Kyriakou, Y.
    Kalender, W. A.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 2 - DIAGNOSTIC IMAGING, 2009, 25 : 394 - 397
  • [34] First pass cable artefact correction for cardiac C-arm CT imaging
    Haase, C.
    Schaefer, D.
    Kim, M.
    Chen, S. J.
    Carroll, J. D.
    Eshuis, P.
    Doessel, O.
    Grass, M.
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (14) : 3861 - 3875
  • [35] A review of the image segmentation and registration methods in liver motion correction in C-arm perfusion imaging
    Haseljic, Hana
    Frysch, Robert
    Kulvait, Vojtech
    Rose, Georg
    2019 XXVII INTERNATIONAL CONFERENCE ON INFORMATION, COMMUNICATION AND AUTOMATION TECHNOLOGIES (ICAT 2019), 2019,
  • [36] Shifted Detector Super Short Scan Reconstruction for the Rotate-Plus-Shift Trajectories and its Application to C-arm CT Systems
    Kuntz, Jan
    Knaup, Michael
    Fleischmann, Christof
    Kachelriess, Marc
    MEDICAL IMAGING 2016: PHYSICS OF MEDICAL IMAGING, 2016, 9783
  • [37] Scatter correction using a primary modulator on a clinical angiography C-arm CT system
    Bier, Bastian
    Berger, Martin
    Maier, Andreas
    Kachelriess, Marc
    Ritschl, Ludwig
    Mueller, Kerstin
    Choi, Jang-Hwan
    Fahrig, Rebecca
    MEDICAL PHYSICS, 2017, 44 (09) : E125 - E137
  • [38] Angiography-Based C-Arm CT for the Assessment of Extrahepatic Shunting before Radioembolization
    Heusner, T. A.
    Hamami, M. E.
    Ertle, J.
    Hahn, S.
    Poeppel, T.
    Hilgard, P.
    Bockisch, A.
    Forsting, M.
    Antoch, G.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2010, 182 (07): : 603 - 608
  • [39] Intercostal Artery Supplying Hepatocellular Carcinoma: Demonstration of a Tumor Feeder by C-arm CT and Multidetector Row CT
    Kim, Hyo-Cheol
    Chung, Jin Wook
    Lee, In Joon
    An, Sangbu
    Seong, Nak Jong
    Son, Kyu Ri
    Jae, Hwan Jun
    Park, Jae Hyung
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2011, 34 (01) : 87 - 91
  • [40] Comparison of air kerma between C-arm CT and 64-multidetector-row CT using a phantom
    Seiki Hosokawa
    Nobuyuki Kawai
    Morio Sato
    Hiroki Minamiguchi
    Motoki Nakai
    Kazuhiro Murotani
    Tadayoshi Nishioku
    Shintaro Shirai
    Tetsuo Sonomura
    Japanese Journal of Radiology, 2014, 32 : 302 - 307