Fast Dynamic Reconstruction Algorithm with Joint Bilateral Filtering for Perfusion C-arm CT

被引:0
作者
Manhart, Michael [1 ]
Kowarschik, Markus [2 ]
Fieselmann, Andreas [1 ,3 ]
Yu Deuerling-Zheng [2 ]
Hornegger, Joachim [1 ,3 ]
机构
[1] Univ Erlangen Nurnberg, Pattern Recognit Lab, Dept Comp Sci, Martensstr 3, D-91058 Erlangen, Germany
[2] Siemens AG, Angiog & Intervent X Ray Syst, Forchheim, Germany
[3] Erlangen Grad Sch Adv Opt Technol SAOT, Erlangen, Germany
来源
2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC) | 2012年
关键词
Perfusion imaging; dynamic reconstruction; C-arm CT; stroke treatment; MODEL;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Tissue perfusion measurement using C-arm angiography systems is a novel technique with potential high benefit for catheter-guided treatment of stroke in the interventional suite. However, perfusion C-arm CT (PCCT) is challenging: the slow C-arm rotation speed only allows measuring samples of contrast time attenuation curves (TACs) every 5 - 6 s if reconstruction algorithms for static data are used. Furthermore, the peaks of the tissue TACs typically lie in a range of 5 - 30 HU, thus perfusion imaging is very sensitive to noise. We present a dynamic, iterative reconstruction (DIR) approach to reconstruct TACs described by a weighted sum of linear spline functions. The optimization problem is solved using an appropriate initialization and a Landweber-based optimization strategy with a modified backprojection step. To reduce noise a novel regularization technique based on joint bilateral filtering (JBF) is introduced. The algorithm is evaluated using simulation data created with a dynamic cylindrical phantom, a realistic digital brain phantom and real measured data from an animal study with a canine stroke model. Results indicate that the DIR algorithm qualitatively and quantitatively improves reconstructed TACs and perfusion maps compared to classical Feldkamp (FDK) reconstruction. For the brain phantom study the Pearson correlation (PC) of the reconstructed cerebral blood flow (CBF) maps to the ground truth increased from 0.82 (FDK) to 0.87 (DIR). For the canine study the PC of the CBF maps to co-registered perfusion CT maps increased from 0.61 (FDK) to 0.73 (DIR).
引用
收藏
页码:2304 / 2311
页数:8
相关论文
共 50 条
  • [21] Surgical Screw Segmentation for Mobile C-Arm CT Devices
    Goerres, Joseph
    Brehler, Michael
    Franke, Jochen
    Wolf, Ivo
    Vetter, Sven Y.
    Gruetzner, Paul A.
    Meinzer, Hans-Peter
    Nabers, Diana
    MEDICAL IMAGING 2014: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2014, 9036
  • [22] Hardware accelerated C-arm CT and fluoroscopy: A pilot study
    Riabkov, Dmitri
    Brown, Todd
    Cheryauka, Arvi
    Tokhtuev, Alexander
    MEDICAL IMAGING 2008: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2008, 6913
  • [23] Right Adrenal Venography Findings correlated with C-arm CT for Selection During C-arm CT-assisted Adrenal Vein Sampling in Primary Aldosteronism
    Park, Sung Il
    Rhee, Yumie
    Lim, Jung Soo
    Park, Sungha
    Kang, Sang Wook
    Lee, Mu Sook
    Lee, Myungsu
    Lee, Shin Jae
    Kim, Il Jung
    Lee, Do Yun
    Cho, June-Sik
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2014, 37 (06) : 1469 - 1475
  • [24] Developing low-dose C-arm CT imaging for temporomandibular joint (TMJ) disorder in interventional radiology
    Zhu, Xiaowei
    Felice, Marc
    Johnson, Laura
    Sarmiento, Marily
    Cahill, Anne Marie
    PEDIATRIC RADIOLOGY, 2011, 41 (04) : 476 - 482
  • [25] Reduction of beam hardening artifacts on real C-arm CT data using polychromatic statistical image reconstruction
    Bismark, Richard N. K.
    Frysch, Robert
    Abdurahman, Shiras
    Beuing, Oliver
    Blessing, Manuel
    Rose, Georg
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2020, 30 (01): : 40 - 50
  • [26] Developing low-dose C-arm CT imaging for temporomandibular joint (TMJ) disorder in interventional radiology
    Xiaowei Zhu
    Marc Felice
    Laura Johnson
    Marily Sarmiento
    Anne Marie Cahill
    Pediatric Radiology, 2011, 41 : 476 - 482
  • [27] Comparison of Diagnostic Sensitivity of C-arm CT, DSA and CT in Detecting Small HCC
    Zheng, Jiasheng
    Li, Jianjun
    Cui, Xiongwei
    Ye, Hui
    Ye, Linchao
    HEPATO-GASTROENTEROLOGY, 2013, 60 (126) : 1509 - 1512
  • [28] Detection of pulmonary nodules by C-arm CT using a phantom lung: comparison with CT
    Higashihara, Hiroki
    Osuga, Keigo
    Azuma, Takeo
    Nakazawa, Tetsuro
    Yanagawa, Masahiro
    Kikuyama, Ayano
    Maeda, Noboru
    Tomiyama, Noriyuki
    ACTA RADIOLOGICA, 2011, 52 (09) : 964 - 968
  • [29] Detection of Hepatocellular Carcinoma: Comparison of Angiographic C-Arm CT and MDCT
    Iwazawa, Jin
    Ohue, Shoichi
    Hashimoto, Naoko
    Abe, Hisashi
    Hamuro, Masao
    Mitani, Takashi
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (04) : 882 - 887
  • [30] Region Based Perfusion Estimation in Peripherals Using C-arm Systems: a Simulation Study
    Giordano, Marco
    Vonken, Evert-Jan
    Bertram, Matthias
    Mali, Willem
    Viergever, Max A.
    Neukirchen, Christoph
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 2918 - 2921