DIGITAL IMAGE EVALUATION METHOD FOR DIGITAL RADIOGRAPHY

被引:0
|
作者
Mori, Masako [1 ]
Kashiwa, Toshibumi [2 ]
Aoki, Yoshimitsu [3 ]
机构
[1] Hitachi GE Nucl Energy Ltd, Nucl Plant Dept, Plant Design Sect, 3-1-1 Saiwai Cho, Hitachi, Ibaraki 3170073, Japan
[2] Hitachi GE Nucl Energy Ltd, Nucl Syst Qual Assurance Dept, Nucl Plant Serv QA & NDI Sect, Hitachi, Ibaraki 3170073, Japan
[3] Keio Univ, Dept Elect & Elect Engn, Media Sensing Lab, Yokohama, Kanagawa 2238522, Japan
来源
PROCEEDINGS OF THE 18TH INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING 2010, VOL 1 | 2011年
关键词
D O I
暂无
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Digital radiography is getting one of the common radiographic testing techniques in various industries now. However, to apply this new technique to nuclear components radiographic testing, one big issue is how we can evaluate and ensure that the taken images have enough image qualities to be used as inspection record. In film radiography, the IQI, which stands for Image Quality Indicator, have been used to ensure that taken films have enough quality to detect any specified defects in the products. So in this paper, new alternative IQI that developed in our previous study for digital radiography to evaluate digital image quality are tested and evaluated. In addition, image evaluation criteria are also developed and evaluated by calculating MTF, which stands for Modulation Transfer Function, from the IQI images taken with the products. Finally, the recommended procedures to evaluate radiographic testing image are summarized.
引用
收藏
页码:223 / +
页数:3
相关论文
共 50 条
  • [1] DIGITAL IMAGE EVALUATION METHOD FOR DIGITAL RADIOGRAPHY
    Mori, Masako
    Kashiwa, Toshibumi
    Aoki, Yoshimitsu
    PROCEEDINGS OF THE ASME PRESSURE VESSELS AND PIPING CONFERENCE 2010, VOL 5, 2010, : 207 - 213
  • [2] Evaluation of image presentation algorithms for digital radiography
    Schubert, SF
    Kump, KS
    RADIOLOGY, 1999, 213P : 321 - 321
  • [3] Digital image processing in radiography
    Foos, D
    Wang, X
    MEDICAL PHYSICS, 2005, 32 (06) : 2116 - 2116
  • [4] Image processing in digital radiography
    Freedman, MT
    Artz, DS
    SEMINARS IN ROENTGENOLOGY, 1997, 32 (01) : 25 - 37
  • [5] Digital image processing in radiography
    Flynn, M.
    MEDICAL PHYSICS, 2006, 33 (06) : 2226 - 2227
  • [6] Digital image processing in radiography
    Flynn, M.
    MEDICAL PHYSICS, 2007, 34 (06) : 2578 - 2578
  • [7] Digital radiography of scoliosis with a scanning method: Initial evaluation
    Geijer, H
    Beckman, KW
    Jonsson, B
    Andersson, T
    Persliden, J
    RADIOLOGY, 2001, 218 (02) : 402 - 410
  • [8] Developing a novel phantom for image quality evaluation in digital radiography
    Yalcin, Asena
    Olgar, Turan
    RADIATION PHYSICS AND CHEMISTRY, 2024, 222
  • [9] Evaluation of Image Quality in Digital Radiography Based On Marginal Detectability
    Scott, A.
    Zhou, Y.
    Zhang, D.
    Binesh, N.
    Lee, C.
    Bosteder, W.
    MEDICAL PHYSICS, 2020, 47 (06) : E534 - E534
  • [10] Image Quality Evaluation of a Digital Radiography System Made in Thailand
    Techavipoo, Udomchai
    Sinsuebphon, Nattawut
    Prompalit, Sakunrat
    Thongvigitmanee, Saowapak
    Narkbuakaew, Walita
    Kiang-ia, Atthasak
    Srivongsa, Tanapon
    Thajchayapong, Pairash
    Chaumrattanakul, Utairat
    BIOMED RESEARCH INTERNATIONAL, 2021, 2021