Comparison and Reproducibility of Techniques for Fluid Status Assessment in Chronic Hemodialysis Patients

被引:58
作者
Basso, Flavio [1 ,2 ]
Manani, Sabrina Milan [1 ,2 ]
Cruz, Dinna N. [1 ,2 ]
Teixeira, Catarina [1 ,2 ]
Brendolan, Alessandra [1 ,2 ]
Nalesso, Federico [1 ,2 ]
Zanella, Monica [1 ,2 ]
Ronco, Claudio [1 ,2 ]
机构
[1] St Bortolo Hosp, Dept Nephrol Dialysis & Transplantat, Vicenza, Italy
[2] IRRIV, Vicenza, Italy
关键词
Fluid assessment; Hemodialysis patients; Bioelectrical impedance analysis; Inferior vena cava diameter; Ultrasound lung comets; B-type natriuretic peptide; EXTRAVASCULAR LUNG WATER; BLOOD-PRESSURE; VOLUME STATUS; INTRAVASCULAR VOLUME; CHEST SONOGRAPHY; ULTRASOUND; ECHOCARDIOGRAPHY; BIOIMPEDANCE; OVERLOAD; COMETS;
D O I
10.1159/000351008
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Several methods have been developed to assess the hydration status in chronic hemodialysis (HD) patients. The aim of this study was to compare body bioimpedance spectroscopy (BIS) with ultrasound (US) lung comet score (ULCs), B-type natriuretic peptide (BNP) and inferior vena cava diameter (IVCD) by US for the estimation of dry weight before and after HD and to analyze all methods in terms of fluid status variations induced by HD. An additional aim of this study was to establish the interoperator reproducibility of these methods. Methods: Two nephrologists evaluated BIS, ULCs, IVCD during inspiration (min) and expiration (max), the inferior vena cava collapsibility index (IVCCI) as well as BNP before and after HD in 30 patients. The same operators measured BIS, ULCs and IVCD in 28 HD patients in a blinded fashion. Results: There was a significant reduction in BIS, ULCs, IVCD and BNP after HD (p < 0.001), but a less significant reduction in IVCCI (p = 0.13). There was a significant correlation between BIS and ULCs, BNP and indexed IVCD (IVCDi)min (p < 0.05) before and after HD, and between BIS and IVCDimax only before HD. Conclusion: All methods were able to describe hyperhydration before and after HD, except for IVCCI after HD. All techniques correlated with BIS before HD. After HD, ULCs correlated better with BIS than IVCD in terms of evaluation of fluid status. It could be expected that the ULCs can give a real-time evaluation of interstitial water. The reproducibility of the measurement of BIS, IVCD and ULCs between the two operators was high. Copyright (c) 2013 S. Karger AG, Basel
引用
收藏
页码:104 / 112
页数:9
相关论文
共 21 条
[1]   Inferior Vena Cava Diameter and Left Atrial Diameter Measure Volume but Not Dry Weight [J].
Agarwal, Rajiv ;
Bouldin, J. Michael ;
Light, Robert P. ;
Garg, Ashok .
CLINICAL JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2011, 6 (05) :1066-1072
[2]   Handcarried ultrasound measurement of the inferior vena cava for assessment of intravascular volume status in the outpatient hemodialysis clinic [J].
Brennan, J. Matthew ;
Ronan, Adam ;
Goonewardena, Sascha ;
Blair, John E. A. ;
Hammes, Mary ;
Shah, Dipak ;
Vasaiwala, Samip ;
Kirkpatrick, James N. ;
Spencer, Kirk T. .
CLINICAL JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2006, 1 (04) :749-753
[3]   PlasmaBNP, a useful marker of fluid overload in hospitalized hemodialysis patients [J].
Celik, Gulperi ;
Silinou, Emilie ;
Vo-Van, Cyril ;
Jean, Guillaume ;
Chazot, Charles .
HEMODIALYSIS INTERNATIONAL, 2012, 16 (01) :47-52
[4]  
Charra Bernard, 2007, Hemodial Int, V11, P21, DOI 10.1111/j.1542-4758.2007.00148.x
[5]  
Coppola Alessandro, 2005, Ann Ital Med Int, V20, P167
[6]   A systematic evaluation of bioelectrical impedance measurement after hemodialysis session [J].
Di Iorio, BR ;
Scalfi, L ;
Terracciano, V ;
Bellizzi, V .
KIDNEY INTERNATIONAL, 2004, 65 (06) :2435-2440
[7]   Combining tissue Doppler echocardiography and B-type natriuretic peptide in the evaluation of left ventricular filling pressures: Review of the literature and clinical recommendations [J].
Dokainish, Hisham .
CANADIAN JOURNAL OF CARDIOLOGY, 2007, 23 (12) :983-989
[8]  
DON C, 1990, J CAN ASSOC RADIOL, V41, P123
[9]   Prognostic value of extravascular lung water assessed with ultrasound lung comets by chest sonography in patients with dyspnea and/or chest pain [J].
Frassi, Francesca ;
Gargani, Luna ;
Tesorio, Paola ;
Raciti, Mauro ;
Mottola, Gaetano ;
Picano, Eugenio .
JOURNAL OF CARDIAC FAILURE, 2007, 13 (10) :830-835
[10]   Ultrasound lung comets in systemic sclerosis: a chest sonography hallmark of pulmonary interstitial fibrosis [J].
Gargani, Luna ;
Doveri, Marica ;
D'Errico, Luigia ;
Frassi, Francesca ;
Bazzichi, Maria L. ;
Delle Sedie, Andrea ;
Scali, Maria C. ;
Monti, Simonetta ;
Mondillo, Sergio ;
Bombardieri, Stefano ;
Caramella, Davide ;
Picano, Eugenio .
RHEUMATOLOGY, 2009, 48 (11) :1382-1387