In situ activated nanostructured platform for oxidized glutathione biosensing

被引:10
作者
Correa, Catia Crispilho [1 ,3 ]
Santhiago, Murilo [1 ,3 ]
Barboza Formiga, Andre Luiz [2 ]
Kubota, Lauro Tatsuo [1 ,3 ]
机构
[1] Inst Chem UNICAMP, Dept Analyt Chem, BR-13083970 Campinas, SP, Brazil
[2] Inst Chem UNICAMP, Dept Inorgan Chem, BR-13083970 Campinas, SP, Brazil
[3] Univ Estadual Campinas, Natl Inst Sci & Technol Bioanalyt, BR-13083970 Campinas, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
MWCNTs; 3,5-Dinitrobenzoic acid; Nanostructured platform; NADH; GSSG detection and amperometric biosensor; PERFORMANCE LIQUID-CHROMATOGRAPHY; MULTIWALLED CARBON NANOTUBES; MODIFIED ELECTRODES; OXIDATIVE STRESS; DISULFIDE LEVELS; NADH DETECTION; HUMAN PLASMA; L-CYSTEINE; NANOCOMPOSITES; REDUCTASE;
D O I
10.1016/j.electacta.2012.12.046
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
This work describes the construction of a biosensor for glutathione disulfide (GSSG) based on a nanostructured platform composed by MWCNTs, chitosan (CHIT) and the redox mediator 3,5-dinitrobenzoic acid. The dispersion of MWCNTs and CHIT showed a good stability and was used to modify the glassy carbon electrode (GCE). The nanostructured platform was characterized by scanning electron microscopy (SEM) and electrochemical techniques. The R-NO/R-NHOH redox couple was electrogenerated in situ by cycling the potential between 0.2 and -0.4V vs. SCE. After activating the nanostructured platform, glutathione reductase was easily immobilized on the electrode surface by using glutaraldehyde as functional linker. The biosensor performance was optimized in terms of amount of enzyme, effect of CHIT concentration and NADH amount. Under optimized conditions, the biosensor response for GSSG sensing was linear from 2.0 up to 35 mu mol L-1 with detection and quantification limits achieving values of 0.6 and 2.0 mu mol L-1, respectively and sensitivity of 6.24 mA L mol(-1). The apparent Michaelis-Menten constant (K-M(app)) obtained by amperometry for the immobilized glutathione reductase on the nanostructured platform was 60 mu mol L-1. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:309 / 316
页数:8
相关论文
共 46 条
[1]  
ANDRIEUX CP, 1978, J ELECTROANAL CHEM, V93, P163, DOI 10.1016/S0022-0728(78)80230-7
[2]  
Annuk M, 2001, J AM SOC NEPHROL, V12, P2747, DOI 10.1681/ASN.V12122747
[3]  
[Anonymous], 1987, ANALYST, V112, P199
[4]  
[Anonymous], 2001, ELECTROCHEMICAL METH
[5]   Determination of glutathione disulfide levels in biological samples using thiol-disulfide exchanging agent, dithiothreitol [J].
Ates, Burhan ;
Ercal, Baris Can ;
Manda, Kalyan ;
Abraham, Linu ;
Ercal, Nuran .
BIOMEDICAL CHROMATOGRAPHY, 2009, 23 (02) :119-123
[6]   INCREASED LEVELS OF OXIDIZED GLUTATHIONE IN CD4(+) LYMPHOCYTES ASSOCIATED WITH DISTURBED INTRACELLULAR REDOX BALANCE IN HUMAN-IMMUNODEFICIENCY-VIRUS TYPE-1 INFECTION [J].
AUKRUST, P ;
SVARDAL, AM ;
MULLER, F ;
LUNDEN, B ;
BERGE, RK ;
UELAND, PM ;
FROLAND, SS .
BLOOD, 1995, 86 (01) :258-267
[7]   Exploring the electrocatalytic sites of carbon nanotubes for NADH detection: an edge plane pyrolytic graphite electrode study [J].
Banks, CE ;
Compton, RG .
ANALYST, 2005, 130 (09) :1232-1239
[8]   STUDY OF A REAGENTLESS LACTATE ELECTRODE [J].
BLAEDEL, WJ ;
JENKINS, RA .
ANALYTICAL CHEMISTRY, 1976, 48 (08) :1240-1247
[9]   DETERMINATION OF GLUTATHIONE IN BIOLOGICAL-MATERIAL BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION [J].
BUCHBERGER, W ;
WINSAUER, K .
ANALYTICA CHIMICA ACTA, 1987, 196 :251-254
[10]   Construction of a new functional platform by grafting poly(4-vinylpyridine) in multi-walled carbon nanotubes for complexing copper ions aiming the amperometric detection of L-cysteine [J].
Castro e Silva, Cecilia de Carvalho ;
Breitkreitz, Marcia Cristina ;
Santhiago, Murilo ;
Correa, Catia Crispilho ;
Kubota, Lauro Tatsuo .
ELECTROCHIMICA ACTA, 2012, 71 :150-158