MULTILEVEL NUMERICAL MODEL OF HIP JOINT ACCOUNTING FOR FRICTION IN THE HIP RESURFACING ENDOPROSTHESIS

被引:13
作者
Eremina, Galina M. [1 ]
Smolin, Alexey Yu [2 ]
机构
[1] Inst Strength Phys & Mat Sci SB RAS, Pr Akad Skii 2-4, Tomsk 634055, Russia
[2] Tomsk State Univ, Tomsk, Russia
关键词
Hip Resurfacing Endoprosthesis; Coatings; Scratch Test; Friction; Simulation; Movable Cellular Automaton Method; HARD COATINGS; NANOINDENTATION; PERFORMANCE; ROUGHNESS; THICKNESS; ADHESION; STRESSES;
D O I
10.22190/FUME190122014E
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Friction between the moving parts of the endoprosthesis has a significant impact on the endoprosthesis operation time. Primarily, it concerns the endoprosthesis of hip and knee joints. To improve the tribological characteristics of the metal endoprosthesis, hardening nanostructured coatings are used. Usually, titanium and titanium alloys are used as metal, and titanium nitride is used as a coating. Herein, we propose an approach to multilevel modeling of the system "bone-endoprosthesis" which is based on the movable cellular automaton method and accounts for friction between the moving parts of the hip resurfacing endoprosthesis. We validated the models of the friction system materials using the instrumented scratch test simulation. Then, we simulated friction at the mesolevel, explicitly considering roughness of the coating. The results obtained at the mesolevel were used as tribological characteristics of the coating in the macroscopic model of the hip resurfacing endoprosthesis.
引用
收藏
页码:29 / 38
页数:10
相关论文
共 29 条
[1]  
[Anonymous], 2000, MAT DAT TIMETAL 6 4S
[2]   Biological response to prosthetic debris [J].
Bitar, Diana ;
Parvizi, Javad .
WORLD JOURNAL OF ORTHOPEDICS, 2015, 6 (02) :172-189
[3]   Evaluating the effects of PIRAC nitrogen-diffusion treatments on the mechanical performance of Ti-6Al-4V alloy [J].
Bonello, T. ;
Wilson, J. C. Avelar-Batista ;
Housden, J. ;
Gutmanas, E. Y. ;
Gotman, I. ;
Matthews, A. ;
Leyland, A. ;
Cassar, G. .
MATERIALS SCIENCE AND ENGINEERING A-STRUCTURAL MATERIALS PROPERTIES MICROSTRUCTURE AND PROCESSING, 2014, 619 :300-311
[4]   The effect of specimen roughness and indenter tip geometry on the determination accuracy of thin hard coatings stress-strain laws by nanoindentation [J].
Bouzakis, KD ;
Michailidis, N ;
Hadjiyiannis, S ;
Skordaris, G ;
Erkens, G .
MATERIALS CHARACTERIZATION, 2002, 49 (02) :149-156
[5]   Finite element analysis of a femoral retrograde intramedullary nail subject to gait loading [J].
Cheung, G ;
Zalzal, P ;
Bhandari, M ;
Spelt, JK ;
Papini, M .
MEDICAL ENGINEERING & PHYSICS, 2004, 26 (02) :93-108
[6]   A fatigue assessment technique for modular and pre-stressed orthopaedic implants [J].
Dickinson, A. S. ;
Browne, M. ;
Rogues, A. C. ;
Taylor, A. C. .
MEDICAL ENGINEERING & PHYSICS, 2014, 36 (01) :72-80
[7]   Implant-bone interface healing and adaptation in resurfacing hip replacement [J].
Dickinson, Alexander ;
Taylor, Andrew ;
Browne, Martin .
COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2012, 15 (09) :935-947
[8]   Bioactive Glass and Glass-Ceramic Scaffolds for Bone Tissue Engineering [J].
Gerhardt, Lutz-Christian ;
Boccaccini, Aldo R. .
MATERIALS, 2010, 3 (07) :3867-3910
[9]   Determination of elastoplastic properties by instrumented sharp indentation [J].
Giannakopoulos, AE ;
Suresh, S .
SCRIPTA MATERIALIA, 1999, 40 (10) :1191-1198
[10]  
Gotman I., 2017, COMPREHENSIVE BIOMAT, V1, P165