Estimating Effective Dose of Radiation From Pediatric Cardiac CT Angiography Using a 64-MDCT Scanner: New Conversion Factors Relating Dose-Length Product to Effective Dose

被引:17
|
作者
Trattner, Sigal [1 ]
Chelliah, Anjali [2 ]
Prinsen, Peter [3 ]
Ruzal-Shapiro, Carrie B. [4 ]
Xu, Yanping [5 ]
Jambawalikar, Sachin [4 ]
Amurao, Maxwell [6 ]
Einstein, Andrew J. [1 ,4 ,7 ]
机构
[1] Columbia Univ, Dept Med, Div Cardiol, Med Ctr, 622 W 168th St,PH 10-203A, New York, NY 10032 USA
[2] Columbia Univ, Med Ctr, New York Presbyterian Morgan Stanley Childrens Ho, Dept Pediat,Pediat Cardiol Div, New York, NY USA
[3] Philips Healthcare Res, Eindhoven, Netherlands
[4] Columbia Univ, Dept Radiol, Med Ctr, 622 W 168th St,PH 10-203A, New York, NY 10032 USA
[5] Columbia Univ, Ctr Radiol Res, Radiol Res Accelerator Facil, Irvington, NY USA
[6] Columbia Univ, Med Ctr, Radiat Safety Off, New York, NY USA
[7] New York Presbyterian Hosp, 622 W 168th St,PH 10-203A, New York, NY 10032 USA
基金
美国国家卫生研究院;
关键词
conversion factor; dose-length product; effective dose; pediatric cardiac CT; radiation; COMPUTED-TOMOGRAPHY ANGIOGRAPHY; SUBSEQUENT RISK; CANCER-RISK; CHILDREN; ACCURACY; INFANTS; CHILDHOOD; EXPOSURE; DISEASE; TRENDS;
D O I
10.2214/AJR.15.15908
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this study is to determine the conversion factors that enable accurate estimation of the effective dose (ED) used for cardiac 64-MDCT angiography performed for children. MATERIALS AND METHODS. Anthropomorphic phantoms representative of 1- and 10-year-old children, with 50 metal oxide semiconductor field-effect transistor dosimeters placed in organs, underwent scanning performed using a 64-MDCT scanner with different routine clinical cardiac scan modes and x-ray tube potentials. Organ doses were used to calculate the ED on the basis of weighting factors published in 1991 in International Commission on Radiological Protection (ICRP) publication 60 and in 2007 in ICRP publication 103. The EDs and the scanner-reported dose-length products were used to determine conversion factors for each scan mode. The effect of infant heart rate on the ED and the conversion factors was also assessed. RESULTS. The mean conversion factors calculated using the current definition of ED that appeared in ICRP publication 103 were as follows: 0.099 mSv center dot mGy(-1) center dot cm(-1), for the 1-year-old phantom, and 0.049 mSv center dot mGy(-1) center dot cm(-1), for the 10-year-old phantom. These conversion factors were a mean of 37% higher than the corresponding conversion factors calculated using the older definition of ED that appeared in ICRP publication 60. Varying the heart rate did not influence the ED or the conversion factors. CONCLUSION. Conversion factors determined using the definition of ED in ICRP publication 103 and cardiac, rather than chest, scan coverage suggest that the radiation doses that children receive from cardiac CT performed using a contemporary 64-MDCT scanner are higher than the radiation doses previously reported when older chest conversion factors were used. Additional up-to-date pediatric cardiac CT conversion factors are required for use with other contemporary CT scanners and patients of different age ranges.
引用
收藏
页码:585 / 594
页数:10
相关论文
共 34 条
  • [1] Cardiac-Specific Conversion Factors to Estimate Radiation Effective Dose From Dose-Length Product in Computed Tomography
    Trattner, Sigal
    Halliburton, Sandra
    Thompson, Carla M.
    Xu, Yanping
    Chelliah, Anjali
    Jambawalikar, Sachin R.
    Peng, Boyu
    Peters, M. Robert
    Jacobs, Jill E.
    Ghesani, Munir
    Jang, James J.
    Al-Khalidi, Hussein
    Einstein, Andrew J.
    JACC-CARDIOVASCULAR IMAGING, 2018, 11 (01) : 64 - 74
  • [2] Conversion from dose-length product to effective dose in computed tomography venography of the lower extremities
    Inoue, Yusuke
    Yonekura, Yuka
    Nagahara, Kazunori
    Uehara, Ayuka
    Ikuma, Hideki
    JOURNAL OF RADIOLOGICAL PROTECTION, 2022, 42 (01)
  • [3] Lung Cancer Screening CT Sex-Specific Conversion Factors to Estimate Effective Radiation Dose From Dose-Length Product
    Cohen, Stuart L.
    Wang, Jason J.
    Chan, Nicholas
    O'Connell, William
    Shah, Rakesh
    Sanelli, Pina
    Raoof, Suhail
    CHEST, 2019, 156 (06) : 1214 - 1222
  • [4] Dose-Length Product to Effective Dose Conversion Factors for Common Computed Tomography Examinations Based on Canadian Clinical Experience
    Elbakri, Idris A.
    Kirkpatrick, Kin D. C.
    CANADIAN ASSOCIATION OF RADIOLOGISTS JOURNAL-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES, 2013, 64 (01): : 15 - 17
  • [5] How to Appropriately Calculate Effective Dose for CT Using Either Size-Specific Dose Estimates or Dose-Length Product
    Brady, Samuel L.
    Mirro, Amy E.
    Moore, Bria M.
    Kaufman, Robert A.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 204 (05) : 953 - 958
  • [6] Comparing Dose-Length Product-Based and Monte Carlo Simulation Organ-Based Calculations of Effective Dose in 16-and 64-MDCT Examinations Using Automatic Tube Current Modulation
    Haji-Momenian, Shawn
    Ellenbogen, Amy
    Khati, Nadia
    Taffel, Myles
    Earls, James
    Miller, Greggory
    Zeman, Robert K.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2018, 210 (03) : 583 - 592
  • [7] CT effective dose per dose length product using ICRP 103 weighting factors
    Huda, Walter
    Magill, Dennise
    He, Wenjun
    MEDICAL PHYSICS, 2011, 38 (03) : 1261 - 1265
  • [8] Conversion from dose length product to effective dose for the CT component of whole-body PET/CT
    Yusuke Inoue
    Yu Ohkubo
    Kazunori Nagahara
    Ayuka Uehara
    Makoto Takano
    Annals of Nuclear Medicine, 2022, 36 : 411 - 419
  • [9] Conversion from dose length product to effective dose for the CT component of whole-body PET/CT
    Inoue, Yusuke
    Ohkubo, Yu
    Nagahara, Kazunori
    Uehara, Ayuka
    Takano, Makoto
    ANNALS OF NUCLEAR MEDICINE, 2022, 36 (04) : 411 - 419
  • [10] Spatial Resolution and Radiation Dose of a 64-MDCT Scanner Compared with Published CT Urography Protocols
    Vrtiska, Terri J.
    Hartman, Robert P.
    Kofler, James M.
    Bruesewitz, Michael R.
    King, Bernard F.
    McCollough, Cynthia H.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 192 (04) : 941 - 948