摘要
This paper presents a novel fiber optic tactile probedesigned for tissue palpation during minimally invasive surgery (MIS). The probe consists of 3x4 tactile sensing elements at 2.6mm spacing with a dimension of 12x18x8 mm(3) allowing its application via a 25mm surgical port. Each tactile element converts the applied pressure values into a circular image pattern. The image patterns of all the sensing elements are captured by a camera attached at the proximal end of the sensor system. Processing the intensity and the area of these circular patterns allows the computation of the applied pressure across the sensing array. Validation tests show that each sensing element of the tactile probe can measure forces from 0 to 1N with a resolution of 0.05 N. The proposed sensing concept is low cost, lightweight, sterilizable, easy to be miniaturized and compatible for magnetic resonance (MR) environments. Experiments using the developed sensor for tissue abnormality detection were conducted. Results show that the proposed tactile probe can accurately and effectively detect nodules embedded inside soft tissue, demonstrating the promising application of this probe for surgical palpation during MIS.
引用
收藏
页码:2539 / 2544
页数:6
相关论文
共 50 条
  • [41] Air-Cushion Force-Sensitive Probe for Soft Tissue Investigation During Minimally Invasive Surgery
    Zbyszewski, Dinusha
    Challacombe, Benjamin
    Liu, Hongbin
    Seneviratne, Lakmal
    Dasgupta, Prokar
    Murphy, Declan
    Althoefer, Kaspar
    JOURNAL OF ENDOUROLOGY, 2009, 23 (09) : 1421 - 1424
  • [42] Actuator array for use in minimally invasive surgery
    Forschungzentrum Karlsruhe GmbH, Karlsruhe, Germany
    J Phy IV JP, 5 (C5-609-C5-614):
  • [43] Actuator array for use in minimally invasive surgery
    Fischer, H
    Trapp, R
    Schule, L
    Hoffmann, B
    JOURNAL DE PHYSIQUE IV, 1997, 7 (C5): : 609 - 614
  • [44] Development of a Fiber Bragg Grating-Based Force Sensor for Minimally Invasive Surgery-Case Study of Ex-Vivo Tissue Palpation
    Gan, Lu
    Duan, Wenke
    Akinyemi, Toluwanimi Oluwadara
    Du, Wenjing
    Omisore, Olatunji Mumini
    Wang, Lei
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2023, 72
  • [45] Tissue Extraction Techniques for Leiomyomas and Uteri During Minimally Invasive Surgery
    Siedhoff, Matthew T.
    Cohen, Sarah L.
    OBSTETRICS AND GYNECOLOGY, 2017, 130 (06): : 1251 - 1260
  • [46] Role of combined tactile and kinesthetic feedback in minimally invasive surgery
    Lim, Soo-Chul
    Lee, Hyung-Kew
    Park, Joonah
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2015, 11 (03): : 360 - 374
  • [47] Graphical representation of tactile sensing data in Minimally Invasive Surgery
    Ramezanifard, Mohammadreza
    Dargahi, Javad
    Xie, Wen-Fang
    2007 IEEE INTERNATIONAL CONFERENCE ON SYSTEMS, MAN AND CYBERNETICS, VOLS 1-8, 2007, : 1222 - 1227
  • [48] MODELING AND ANALYSIS OF A MICROMACHINED TACTILE SENSOR FOR MINIMALLY INVASIVE SURGERY
    Qasaimeh, Mohammad Ameen
    Stiharu, Ion
    Dargahi, Javad
    ADVANCES IN DYNAMICS, INSTRUMENTATION AND CONTROL, VOL II, 2007, : 315 - 324
  • [49] Design and Analysis of A Tactile Sensor Used in Minimally Invasive Surgery
    Li, Cheng Gang
    Shen, Jing Jin
    2013 IEEE/ASME INTERNATIONAL CONFERENCE ON ADVANCED INTELLIGENT MECHATRONICS (AIM): MECHATRONICS FOR HUMAN WELLBEING, 2013, : 1454 - 1457
  • [50] A Piezoresistive Based Tactile Sensor for Use in Minimally Invasive Surgery
    Atieh, A.
    Ahmadi, R.
    Kalantari, M.
    Dargahi, J.
    Packirisamy, M.
    2011 IEEE 37TH ANNUAL NORTHEAST BIOENGINEERING CONFERENCE (NEBEC), 2011,