Fiber Optics Tactile Array Probe for Tissue Palpation during Minimally Invasive Surgery

被引:0
|
作者
Xie, Hui [1 ]
Liu, Hongbin [1 ]
Luo, Shan [1 ]
Seneviratne, Lakmal D. [1 ]
Althoefer, Kaspar [1 ]
机构
[1] Kings Coll London, Dept Informat, Ctr Robot Res, London, England
关键词
palpation probe; tactile sensor; optical fiber array; MR compatible; FORCE;
D O I
暂无
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
This paper presents a novel fiber optic tactile probedesigned for tissue palpation during minimally invasive surgery (MIS). The probe consists of 3x4 tactile sensing elements at 2.6mm spacing with a dimension of 12x18x8 mm(3) allowing its application via a 25mm surgical port. Each tactile element converts the applied pressure values into a circular image pattern. The image patterns of all the sensing elements are captured by a camera attached at the proximal end of the sensor system. Processing the intensity and the area of these circular patterns allows the computation of the applied pressure across the sensing array. Validation tests show that each sensing element of the tactile probe can measure forces from 0 to 1N with a resolution of 0.05 N. The proposed sensing concept is low cost, lightweight, sterilizable, easy to be miniaturized and compatible for magnetic resonance (MR) environments. Experiments using the developed sensor for tissue abnormality detection were conducted. Results show that the proposed tactile probe can accurately and effectively detect nodules embedded inside soft tissue, demonstrating the promising application of this probe for surgical palpation during MIS.
引用
收藏
页码:2539 / 2544
页数:6
相关论文
共 50 条
  • [1] An Optical Tactile Array Probe Head for Tissue Palpation During Minimally Invasive Surgery
    Xie, Hui
    Liu, Hongbin
    Seneviratne, Lakmal D.
    Althoefer, Kaspar
    IEEE SENSORS JOURNAL, 2014, 14 (09) : 3283 - 3291
  • [2] A High-Sensitivity Tactile Sensor Array Based on Fiber Bragg Grating Sensing for Tissue Palpation in Minimally Invasive Surgery
    Li, Tianliang
    Shi, Chaoyang
    Ren, Hongliang
    IEEE-ASME TRANSACTIONS ON MECHATRONICS, 2018, 23 (05) : 2306 - 2315
  • [3] Air-float Palpation Probe for Tissue Abnormality Identification During Minimally Invasive Surgery
    Wanninayake, Indika B.
    Dasgupta, Prokar
    Seneviratne, Lakmal D.
    Althoefer, Kaspar
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2013, 60 (10) : 2735 - 2744
  • [4] Balloon-integrated pneumatic tactile sensor for tissue palpation in minimally invasive surgery
    Tano, Naoki
    Hatsuzawa, Takeshi
    SENSORS AND ACTUATORS A-PHYSICAL, 2023, 363
  • [5] Discretely Loaded Beam-Type Optical Fiber Tactile Sensor for Tissue Manipulation and Palpation in Minimally Invasive Robotic Surgery
    Ahmadi, Roozbeh
    Packirisamy, Muthukumaran
    Dargahi, Javad
    Cecere, Renzo
    IEEE SENSORS JOURNAL, 2012, 12 (01) : 22 - 32
  • [6] A miniature piezoelectric spiral tactile sensor for tissue hardness palpation with catheter robot in minimally invasive surgery
    Ju, Feng
    Wang, Yaming
    Zhang, Zhao
    Wang, Yaoyao
    Yun, Yahui
    Guo, Hao
    Chen, Bai
    SMART MATERIALS AND STRUCTURES, 2019, 28 (02)
  • [7] Uniaxial Wireless Tissue Palpation Device for Minimally Invasive Surgery
    Beccani, Marco
    Di Natali, Christian
    Rentschler, Mark
    Valdastri, Pietro
    JOURNAL OF MEDICAL DEVICES-TRANSACTIONS OF THE ASME, 2013, 7 (02):
  • [8] Low-Cost Disposable Tactile Sensors for Palpation in Minimally Invasive Surgery
    Naidu, Anish S.
    Patel, Rajni V.
    Naish, Michael D.
    IEEE-ASME TRANSACTIONS ON MECHATRONICS, 2017, 22 (01) : 127 - 137
  • [9] Tactile needle probe for minimally invasive tissue identification during epidural space insertion
    Mo, Zonglai
    Li, Jun
    Xu, Weiliang
    OPTIK, 2021, 242
  • [10] Enhanced Tactile Sensor for the Minimally Invasive Robotic Palpation
    Kwon, Joon Ho
    Hwang, Jung-Hoon
    An, Jinung
    Yang, Gi-Hun
    Hong, Daehie
    2014 IEEE/ASME INTERNATIONAL CONFERENCE ON ADVANCED INTELLIGENT MECHATRONICS (AIM), 2014, : 1375 - 1380