A novel method for determining the nature of time series

被引:47
作者
Gautama, T
Mandic, DP [1 ]
Van Hulle, MM
机构
[1] Univ London Imperial Coll Sci Technol & Med, Dept Elect & Elect Engn, London SW7 2BT, England
[2] Katholieke Univ Leuven, Neuro & Psychofysiol Lab, Louvain, Belgium
关键词
fMRI; HRV; nonlinearity analysis; surrogate data;
D O I
10.1109/TBME.2004.824122
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The delay vector variance (DVV) method, which analyzes the nature of a time series with respect to the prevalence of deterministic or stochastic components, is introduced. Due to the standardization within the DVV method, it is possible both to statistically test for the presence of nonlinearities in a time series, and to visually inspect the results in a DVV scatter diagram. This approach is convenient for interpretation as it conveys information about the linear or nonlinear nature, as well as about the prevalence of deterministic or stochastic components in the time series, thus unifying the existing approaches which deal either with only deterministic versus stochastic, or the linear versus nonlinear aspect. The results on biomedical time series, namely heart rate variability (HRV) and functional Magnetic Resonance Imaging (fMRI) time series, illustrate the applicability of the proposed DVV-method.
引用
收藏
页码:728 / 736
页数:9
相关论文
共 22 条
[1]   NEW LOOK AT STATISTICAL-MODEL IDENTIFICATION [J].
AKAIKE, H .
IEEE TRANSACTIONS ON AUTOMATIC CONTROL, 1974, AC19 (06) :716-723
[2]  
[Anonymous], RECURRENT NEURAL NET
[3]  
Casdagli M.C., 1994, TIME SERIES PREDICTI
[4]   APPLICATION OF LINEAR AND NONLINEAR TIME-SERIES MODELING TO HEART-RATE DYNAMICS ANALYSIS [J].
CHRISTINI, DJ ;
BENNETT, FM ;
LUTCHEN, KR ;
AHMED, HM ;
HAUSDORFF, JM ;
ORIOL, N .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1995, 42 (04) :411-415
[5]   REVERSIBILITY AS A CRITERION FOR DISCRIMINATING TIME-SERIES [J].
DIKS, C ;
VANHOUWELINGEN, JC ;
TAKENS, F ;
DEGOEDE, J .
PHYSICS LETTERS A, 1995, 201 (2-3) :221-228
[6]   INDEPENDENT COORDINATES FOR STRANGE ATTRACTORS FROM MUTUAL INFORMATION [J].
FRASER, AM ;
SWINNEY, HL .
PHYSICAL REVIEW A, 1986, 33 (02) :1134-1140
[7]   Nonlinear responses in fMRI: The balloon model, volterra kernels, and other hemodynamics [J].
Friston, KJ ;
Mechelli, A ;
Turner, R ;
Price, CJ .
NEUROIMAGE, 2000, 12 (04) :466-477
[8]  
Guzzetti S, 1996, CARDIOVASC RES, V31, P441
[9]   Practical implementation of nonlinear time series methods: The TISEAN package [J].
Hegger, R ;
Kantz, H ;
Schreiber, T .
CHAOS, 1999, 9 (02) :413-435
[10]  
Ho KKL, 1997, CIRCULATION, V96, P842