Reduction in delay time of high-dwell volume pumps in LC-MS applications using short-term low-ratio split flow

被引:3
作者
Rogatsky, Eduard [1 ]
Cruikshank, Greg [1 ]
Stein, Daniel T. [1 ]
机构
[1] Yeshiva Univ, Albert Einstein Coll Med, Inst Clin & Translat Res, Bronx, NY 10461 USA
基金
美国国家卫生研究院;
关键词
Column switching; Delay time; Dwell volume; Throughput; LIQUID-CHROMATOGRAPHY; C-PEPTIDE; SEPARATION;
D O I
10.1002/jssc.200800393
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We present a simple hardware design which reduces run time of gradient-based LC/MS applications and improves system equilibration. Our approach does not sacrifice efficiency of chromatographic separation, and does not affect analyte retention time and therefore does not require revalidation. Our technical design is based on a six-port/two-position switching valve and flow splitter installed prior to the LC column. This design minimizes time delays caused by the high-dwell volume of some LC pumps. Implementation of short-term (40-55 s) low-ratio (1:10) flow splitting reduced delay times by over four-fold in our application. This approach allowed hardware-associated time delays to be minimized. Alternative plumbing suggestions are also discussed.
引用
收藏
页码:321 / 327
页数:7
相关论文
共 12 条
  • [1] Dolan JW, 2006, LC GC N AM, V24, P458
  • [2] Quantitative analysis of urinary C-peptide by liquid chromatography-tandem mass spectrometry with a stable isotopically labelled internal standard
    Fierens, C
    Thienpont, LMR
    Stöckl, D
    Willekens, E
    De Leenheer, AP
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2000, 896 (1-2) : 275 - 278
  • [3] Effect of the mobile phase composition on the separation and detection of intact proteins by reversed-phase liquid chromatography -: electro spray mass spectrometry
    García, MC
    Hogenboom, AC
    Zappey, H
    Irth, H
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2002, 957 (02) : 187 - 199
  • [4] HUBER U, 2002, PUBLICATION AGILENT
  • [5] Majors RE, 2005, LC GC N AM, V23, P1248
  • [6] Increasing sample throughput in pharmacological studies by using dual-column liquid chromatography with tandem mass spectrometry
    Oertel, R
    Richter, K
    Fauler, J
    Kirch, W
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2002, 948 (1-2) : 187 - 192
  • [7] A validated method for the detection of Δ9-tetrahydrocannabinol and 11-nor-9-carboxy-Δ9-tetrahydrocannabinol in oral fluid samples by liquid chromatography coupled with quadrupole-time-of-flight mass spectrometry
    Quintela, Oscar
    Andrenyak, David M.
    Hoggan, Archie M.
    Crouch, Dennis J.
    [J]. JOURNAL OF ANALYTICAL TOXICOLOGY, 2007, 31 (03) : 157 - 164
  • [8] Direct sensitive quantitative LC/MS analysis of C-peptide from human urine by two dimensional reverse phase/reverse phase high-performance liquid chromatography
    Rogatsky, E
    Tomuta, V
    Cruikshank, G
    Vele, L
    Jayatillake, H
    Stein, D
    [J]. JOURNAL OF SEPARATION SCIENCE, 2006, 29 (04) : 529 - 537
  • [9] High dead volume pumps: Delay time reduction by short-term low-ratio split flow in LC/MS applications
    Rogatsky, Eduard
    Stein, Daniel T.
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2007, 18 (02) : 245 - 247
  • [10] High speed gradient elution reversed-phase liquid chromatography
    Schellinger, AP
    Stoll, DR
    Carr, PW
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2005, 1064 (02) : 143 - 156