Hygrothermal performance of cross-laminated timber wall assemblies with built-in moisture: field measurements and simulations

被引:82
|
作者
McClung, Ruth [1 ]
Ge, Hua [2 ]
Straube, John [3 ]
Wang, Jieying [4 ]
机构
[1] Morrison Hershfield, Vancouver, BC, Canada
[2] Concordia Univ, Montreal, PQ H3G 1M8, Canada
[3] Univ Waterloo, Waterloo, ON N2L 3G1, Canada
[4] FPInnovations, Vancouver, BC V6T 1Z4, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Cross-laminated timber (CLT) wall assemblies; Hygrothermal performance; Field test; Moisture content; Wood; Hygrothermal simulations;
D O I
10.1016/j.buildenv.2013.09.008
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Cross-laminated timber (CLT) panels have potential market in North America for building mid-rise or even taller structures due to their good structural and fire safety performance, light weight, and prefabricated nature. However, to ensure long-term durability when used in building enclosures, the hygrothermal performance of CLT wall assemblies needs to be evaluated in terms of wetting and drying potential. A test wall consisting of sixteen 0.6 m by 0.6 m CLT panels made of five different wood species (or species groups) and four different wall assemblies was constructed. The CLT panels were initially wetted with the moisture content (MC) in the surface layers approaching or exceeding 30%, and monitored for MCs and temperatures at different depths over one year in a building envelope test facility located in Waterloo, Ontario. The drying behaviour of these panels was analysed and the measured MCs over time were compared to simulation results using a commercial hygrothermal program. This field study showed that most of the CLT panels dried to below 26% within one month except for CLT walls with a low-permeance interior membrane, which indicated that none of the CLT walls would likely remain at a high MC level long enough to initiate decay under the conditions tested. The simulation results generally agree well with the field data at MCs below 26%. However, it was found that the hygrothermal simulation program tended to overestimate the MC in the centre of the panels by up to 5-10%, and simulated MCs at locations deep into the CLT panels were not as responsive to changes in ambient conditions, as the measurements indicated for assemblies with high exterior permeance. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:95 / 110
页数:16
相关论文
共 41 条
  • [21] Rolling shear performance of cross-laminated bamboo-balsa timber panels
    Wang, R.
    Shi, J. J.
    Xia, M. K.
    Li, Z.
    CONSTRUCTION AND BUILDING MATERIALS, 2021, 299 (299)
  • [22] Moisture risk assessment of cross-laminated timber walls: Perspectives on climate conditions and water vapor resistance performance of building materials
    Chang, Seong Jin
    Wi, Seunghwan
    Kang, Seog Goo
    Kim, Sumin
    BUILDING AND ENVIRONMENT, 2020, 168
  • [23] The effects of densification on rolling shear performance of southern yellow pine cross-laminated timber
    Pradhan, Suman
    Entsminger, Edward D.
    Mohammadabadi, Mostafa
    Ragon, Kevin
    Nkeuwa, William Nguegang
    CONSTRUCTION AND BUILDING MATERIALS, 2023, 392
  • [24] Effect of Short-Term Simulated Rain Exposure on the Performance of Cross-Laminated Timber Angle Bracket Connections
    Bora, Shrenik
    Sinha, Arijit
    Barbosa, Andre R.
    JOURNAL OF ARCHITECTURAL ENGINEERING, 2022, 28 (04)
  • [25] Modelling the mechanical behaviour of typical wall-to-floor connection systems for cross-laminated timber structures
    Izzi, Matteo
    Polastri, Andrea
    Fragiacomo, Massimo
    ENGINEERING STRUCTURES, 2018, 162 : 270 - 282
  • [26] Comparative assessment of shape related cross-laminated timber building typologies focusing on environmental performance
    Leskovar, Vesna Zegarac
    Zigart, Maja
    Premrov, Miroslav
    Lukman, Rebeka Kovacic
    JOURNAL OF CLEANER PRODUCTION, 2019, 216 : 482 - 494
  • [27] Determination of the moisture change behavior of cross-laminated timber using an optical flow based computer vision technique
    Hofinger, Markus
    Pock, Thomas
    Moosbrugger, Thomas
    WOOD MATERIAL SCIENCE & ENGINEERING, 2019, 14 (05) : 332 - 341
  • [28] Static and dynamic performance of direct hybrid connections of cross-laminated timber with steel, concrete and laminated strand lumber composites
    Carrero, Tulio
    Montano, Jairo
    Santa-Maria, Hernan
    Guindos, Pablo
    LATIN AMERICAN JOURNAL OF SOLIDS AND STRUCTURES, 2020, 17 (04): : 1 - 19
  • [29] Improved low-frequency performance of cross-laminated timber floor panels by informed material selection
    Persson, Peter
    Floden, Ola
    Danielsson, Henrik
    Peplow, Andrew
    Andersen, Lars Vabbersgaard
    APPLIED ACOUSTICS, 2021, 179
  • [30] Dimensional stability and moisture-induced strains in spruce cross-laminated timber (CLT) under sorption/desorption isother
    Chiniforush, A. A.
    Ataei, A.
    Valipour, H. R.
    Ngo, T. D.
    Malek, S.
    CONSTRUCTION AND BUILDING MATERIALS, 2022, 356