Systemic Contact Dermatitis and Allergy to Biomedical Devices

被引:26
作者
Aquino, Marcella [1 ,2 ]
Mucci, Tania [1 ,2 ]
机构
[1] Winthrop Univ Hosp, Sect Allergy & Clin Immunol, Mineola, NY 11501 USA
[2] Winthrop Univ Hosp, Mineola, NY 11501 USA
关键词
Systemic contact dermatitis; Allergic contact dermatitis; Metal allergy; Orthopedic implant; Dental implant; Dental amalgam; Stent; Pacemaker; Intrauterine devices; Biomedical devices; METAL-ON-METAL; TOTAL HIP-ARTHROPLASTY; ORAL LICHENOID LESIONS; PATCH-TEST; HYPERSENSITIVITY REACTIONS; NICKEL HYPERSENSITIVITY; BABOON SYNDROME; NUSS PROCEDURE; ORTHOPEDIC IMPLANTS; JOINT REPLACEMENT;
D O I
10.1007/s11882-013-0365-9
中图分类号
R392 [医学免疫学];
学科分类号
100102 ;
摘要
Systemic contact dermatitis (SCD) refers to a skin condition where an individual who is cutaneously sensitized to an allergen will subsequently react to that same allergen or a cross-reacting allergen via the systemic route. It occurs to allergens including metals, medications, and foods. There has been recent interest in metal allergy as it relates to the implantation of devices such as orthopedic, dental, cardiac, and gynecologic implants. This review will briefly address all causes of systemic contact dermatitis with a special and expanded focus on metal implant allergy. We present literature on SCD to various metal biomedical devices, patch testing for diagnosis of metal allergy pre and post implantation and treatment.
引用
收藏
页码:518 / 527
页数:10
相关论文
共 122 条
[41]   Baboon syndrome resulting from systemic drugs:: is there strife between SDRIFE and allergic contact dermatitis syndrome? [J].
Häusermann, P ;
Harr, T ;
Bircher, AJ .
CONTACT DERMATITIS, 2004, 51 (5-6) :297-310
[42]   Systemic Contact Dermatitis - Kids and Ketchup [J].
Herro, Elise M. ;
Jacob, Sharon E. .
PEDIATRIC DERMATOLOGY, 2013, 30 (03) :e32-e33
[43]   Evaluation of metal allergies in patients with coronary stents [J].
Hillen, U ;
Haude, M ;
Erbel, R ;
Goos, M .
CONTACT DERMATITIS, 2002, 47 (06) :353-356
[44]   Hypersensitivity reactions associated with endovascular devices [J].
Honari, Golara ;
Ellis, Stephen G. ;
Wilkoff, Bruce L. ;
Aronica, Mark A. ;
Svensson, Lars G. ;
Taylor, James S. .
CONTACT DERMATITIS, 2008, 59 (01) :7-22
[45]   DERMATITIS FROM A CHROMIUM DENTAL PLATE [J].
HUBLER, WR ;
HUBLER, WR .
CONTACT DERMATITIS, 1983, 9 (05) :377-383
[46]   The impact of metallic allergy on stent implantation metal allergy and recurrence of in-stent restenosis [J].
Iijima, R ;
Ikari, Y ;
Amiya, E ;
Tanimoto, S ;
Nakazawa, G ;
Kyono, H ;
Hatori, M ;
Miyazawa, A ;
Nakayama, T ;
Aoki, J ;
Nakajima, H ;
Hara, K .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2005, 104 (03) :319-325
[47]   Pacemaker contact dermatitis: The effective use of a polytetrafluorothylene sheet [J].
Ishii, Kensuke ;
Kodani, Eitaro ;
Miyamoto, Shinjiro ;
Otsuka, Toshiaki ;
Hosone, Masaru ;
Ogata, Ken-Ichi ;
Sato, Wataru ;
Matsumoto, Shin ;
Takera, Takeshi ;
Ibuki, Chikao ;
Kusama, Yoshiki ;
Atarashi, Hirotsugu .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2006, 29 (11) :1299-1302
[48]   Oral lichenoid lesions related to dental restorative materials [J].
Issa, Y ;
Duxbury, AJ ;
Macfarlane, TV ;
Brunton, PA .
BRITISH DENTAL JOURNAL, 2005, 198 (06) :361-366
[49]  
Issa Y, 2005, BR DENT J, V198, P549
[50]  
Issa Y, 2005, BR DENT J, V198, P372