The Influence of Ultrasound Ciliary Plasty on Corneal Parameters

被引:3
作者
Bolek, Bartlomiej [1 ]
Wylegala, Adam [1 ]
Wylegala, Edward [1 ]
机构
[1] Med Univ Silesia, Dist Railway Hosp, Sch Med Zabrze, Clin Dept Ophthalmol, Katowice, Poland
关键词
glaucoma; ultrasound ciliary plasty; cyclodestruction; astigmatism; corneal topography; INTENSITY FOCUSED ULTRASOUND; DIODE-LASER CYCLOPHOTOCOAGULATION; TERM-FOLLOW-UP; OPEN-ANGLE GLAUCOMA; TRANSSCLERAL CYCLOPHOTOCOAGULATION; ENDOSCOPIC CYCLOPHOTOCOAGULATION; INTRAOCULAR-PRESSURE; HUMAN AUTOPSY; DEVICE; CYCLOCOAGULATION;
D O I
10.1097/IJG.0000000000001574
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Precis: The ultrasound ciliary plasty (UCP) procedure affects corneal parameters, although the effect is transient. Ultrasound energy affects the sclera, leading to induced astigmatism. The area of energy application correlates with the astigmatism axis. Purpose: To assess the postoperative corneal topography for 1 year after UCP. Materials and Methods: In total, 78 patients with primary and secondary refractory glaucoma were enrolled in the study. The primary outcome measures were the corneal parameters obtained with anterior segment swept-source optical coherence tomography. Intraocular pressure, number of antiglaucoma medications, and best-corrected logMAR visual acuities were analyzed as secondary outcome measures. Measurements were performed preoperatively and at 1 week, and 1, 3, 6, and 12 months postoperatively. A total of 39 patients (39 eyes) completed the follow-up period of 12 months. Results: There was a significant difference in the anterior/posterior steep/flat keratometry and anterior/posterior astigmatism values immediately after UCP. However, 3 months postoperatively these parameters returned to their initial values and there were no significant differences noted. The mean +/- SD values of anterior astigmatism preoperatively and at 1 week, and 1, 3, 6, and 12 months postoperatively were 1.12 +/- 0.66 D, 2.17 +/- 0.91 D (P<0.001), 2.05 +/- 0.93 D (P<0.001), 1.55 +/- 0.75 D (P=0.004), 1.31 +/- 0.70 D (P=0.024), and 1.20 +/- 0.73 D (P=0.406), respectively. The astigmatism axis tended to approach 90 degrees meridian with a significant difference 1 week postoperatively. Central and minimal corneal thickness remained unchanged, whereas the intraocular pressure and the number of antiglaucoma medications decreased significantly. Conclusions: UCP influenced the corneal topography parameters in the immediate postoperative period; however, with time, all parameters returned to their initial values.
引用
收藏
页码:899 / 904
页数:6
相关论文
共 33 条
  • [11] Application of high intensity focused ultrasound for treatment of open-angle glaucoma in Indian patients
    Deb-Joardar, Nilanjana
    Reddy, Kasu Prasad
    [J]. INDIAN JOURNAL OF OPHTHALMOLOGY, 2018, 66 (04) : 517 - 523
  • [12] Denis P., 2016, EUR OPHTHALMIC REV, V10, P108, DOI [10.17925/eor.2016.10.02.108, DOI 10.17925/EOR.2016.10.02.108]
  • [13] Cyclocoagulation of the Ciliary Bodies by High-Intensity Focused Ultrasound: A 12-Month Multicenter Study
    Denis, Philippe
    Aptel, Florent
    Rouland, Jean-Francois
    Nordmann, Jean-Philippe
    Lachkar, Yves
    Renard, Jean-Paul
    Sellem, Eric
    Baudouin, Christophe
    Bron, Alain
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (02) : 1089 - 1096
  • [14] FERRY AP, 1977, T AM ACAD OPHTHALMOL, V83, P90
  • [15] Longterm follow-up of diode laser transscleral cyclophotocoagulation in the treatment of refractory glaucoma
    Frezzotti, Paolo
    Mittica, Vincenzo
    Martone, Gianluca
    Motolese, Ilaria
    Lomurno, Luca
    Peruzzi, Sabrina
    Motolese, Edoardo
    [J]. ACTA OPHTHALMOLOGICA, 2010, 88 (01) : 150 - 155
  • [16] Ultrasound Cyclo-Plasty in Patients with Glaucoma: 1-Year Results from a Multicentre Prospective Study
    Giannaccare, Giuseppe
    Vagge, Aldo
    Sebastiani, Stefano
    Urbini, Lara E.
    Corazza, Paolo
    Pellegrini, Marco
    Carmassi, Luciana
    Bergamini, Fulvio
    Traverso, Carlo E.
    Campos, Emilio C.
    [J]. OPHTHALMIC RESEARCH, 2019, 61 (03) : 137 - 142
  • [17] Comparing the efficacy of trabeculectomy and diode laser cyclophotocoagulation in primary open-angle glaucoma
    Hasan, Somar
    Theilig, Theresa
    Unterlauft, Jan Darius
    [J]. INTERNATIONAL OPHTHALMOLOGY, 2019, 39 (11) : 2485 - 2496
  • [18] Reduction of intraocular pressure and glaucoma progression - Results from the early manifest glaucoma trial
    Heijl, A
    Leske, MC
    Bengtsson, B
    Hyman, L
    Bengtsson, B
    Hussein, M
    [J]. ARCHIVES OF OPHTHALMOLOGY, 2002, 120 (10) : 1268 - 1279
  • [19] CO2 laser-assisted sclerectomy surgery compared with trabeculectomy in primary open-angle glaucoma and exfoliative glaucoma. A 1-year follow-up
    Jankowska-Szmul, Judyta
    Dobrowolski, Dariusz
    Wylegala, Edward
    [J]. ACTA OPHTHALMOLOGICA, 2018, 96 (05) : E582 - E591
  • [20] Kass MA, 2002, ARCH OPHTHALMOL-CHIC, V120, P701