High sensitivity adsorptive stripping voltammetric method for antimony(III) determination in the presence of quercetin-5′-sulfonic acid. Substituent effect on sensitivity

被引:26
作者
Rojas, Carlos [1 ]
Arancibia, Veronica [1 ]
Gomez, Marisol [1 ]
Nagles, Edgar [1 ]
机构
[1] Pontificia Univ Catolica Chile, Fac Quim, Santiago 7820436, Chile
关键词
Antimony; Quercetin-5 '-sulfonic acid; Adsorptive stripping voltammetry; MERCURY DROP ELECTRODE; DIFFERENTIAL-PULSE; SQUARE-WAVE; PLANT ELECTROLYTE; FILM ELECTRODE; NATURAL-WATERS; TRACE ANALYSIS; METALS; COPPER; SPECIATION;
D O I
10.1016/j.snb.2013.05.058
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A high sensitivity method for voltammetric determination of Sb(III) using quercetin-5'-sulfonic acid (QSA) as complexing and adsorbing agent is presented. The Sb-QSA is accumulated on the electrode surface and then reduced at about -0.67 V. Optimal analytical conditions were pH: 5.5, C-QSA: 3.0 mu mol L-1, E-ads: -0.10 V and t(ads): 60 s. The detection limit (3 sigma) depends on accumulation time, reaching 3.6 ng L-1 and 1.6 ng L-1 with t(ads) of 60 s and 180 s, respectively. Peak current is proportional to Sb( III) concentration up to 10.0 mu g L-1 and 1.5 mu g L-1 with t(ads) of 60 s and 180 s, respectively. The relative standard deviation were 1.7% and 2.5% for a solution containing 1.0 mu g L-1 and 5.0 mu g L-1 of Sb(III), respectively (n = 10). Interference by other metal ions was studied. The proposed method was applied to the determination of antimony in natural and spiked water samples, with satisfactory results. The method was designed in order to compare the sensitivity of the methods that use quercetin and the sulfonic derivative. (c) 2013 The Authors. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:560 / 567
页数:8
相关论文
共 52 条
[1]   Combined use of differential pulse adsorptive and anodic stripping techniques for the determination of antimony(III) and antimony(V) in zinc electrolyte [J].
Bond, AM ;
Kratsis, S ;
Newman, OMG .
ANALYTICA CHIMICA ACTA, 1998, 372 (03) :307-314
[2]   Determination of antimony(III) and antimony(V) in copper plant electrolyte by anodic stripping voltammetry [J].
Bond, AM ;
Kratsis, S ;
Newman, OMG .
ELECTROANALYSIS, 1997, 9 (09) :681-684
[3]   Off-line and on-line differential pulse anodic stripping voltammetric techniques for the determination of antimony(III), and antimony(v) in zinc plant electrolyte [J].
Bond, AM ;
Kratsis, S ;
Newman, OMG ;
Pfund, BV .
ELECTROANALYSIS, 1997, 9 (01) :13-18
[4]   Determination of antibilharzial antimony compounds by direct current, differential pulse, square-wave and alternating current anodic stripping voltammetry [J].
Brodersen, K ;
Hassan, HNA ;
Hassouna, MEM ;
Habib, IHI .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1997, 358 (06) :745-748
[5]   Anodic stripping voltammetry of antimony using gold nanoparticle-modified carbon screen-printed electrodes [J].
Dominguez Renedo, Olga ;
Arcos Martinez, M. Julia .
ANALYTICA CHIMICA ACTA, 2007, 589 (02) :255-260
[6]   Determination of Antimony (III) in Real Samples by Anodic Stripping Voltammetry Using a Mercury Film Screen-Printed Electrode [J].
Dominguez-Renedo, Olga ;
Gomez Gonzalez, M. Jesus ;
Julia Arcos-Martinez, M. .
SENSORS, 2009, 9 (01) :219-231
[7]   Chemical Speciation of Antimony(III and V) in Water by Adsorptive Cathodic Stripping Voltammetry Using the 4-(2-Thiazolylazo) - Resorcinol [J].
El-Shahawi, M. S. ;
Bashammakh, A. S. ;
Al-Sibaai, A. A. ;
Bahaffi, S. O. ;
Al-Gohani, E. H. .
ELECTROANALYSIS, 2011, 23 (03) :747-754
[8]   Simultaneous Determination of Antimony and Lead in Gunshot Residue by Cathodic Adsorptive Stripping Voltammetric Methods [J].
Erden, Sevcan ;
Durmus, Zehra ;
Kilic, Esma .
ELECTROANALYSIS, 2011, 23 (08) :1967-1974
[9]   Antimony in the environment: a review focused on natural waters I. Occurrence [J].
Filella, M ;
Belzile, N ;
Chen, YW .
EARTH-SCIENCE REVIEWS, 2002, 57 (1-2) :125-176
[10]   Antimony in the environment: knowns and unknowns [J].
Filella, Montserrat ;
Williams, Peter A. ;
Belzile, Nelson .