Simultaneous multi-gas detection between 3 and 4 μm based on a 2.5-m multipass cell and a tunable Fabry-Perot filter detector

被引:18
作者
Li, Shangzhi [1 ,2 ]
Dong, Lei [1 ,2 ]
Wu, Hongpeng [1 ,2 ]
Yin, Xukun [1 ,2 ,4 ]
Ma, Weiguang [1 ,2 ]
Zhang, Lei [1 ,2 ]
Yin, Wangbao [1 ,2 ]
Sampaolo, Angelo [1 ,3 ]
Patimisco, Pietro [1 ,3 ]
Spagnolo, Vincenzo [1 ,3 ]
Jia, Suotang [1 ,2 ]
Tittel, Frank K. [4 ]
机构
[1] Shanxi Univ, Inst Laser Spect, State Key Lab Quantum Opt & Quantum Opt Devices, Taiyuan 030006, Shanxi, Peoples R China
[2] Shanxi Univ, Collaborat Innovat Ctr Extreme Opt, Taiyuan 030006, Shanxi, Peoples R China
[3] Politecn Bari, PolySense Lab, Phys Dept, I-70100 Bari, Italy
[4] Rice Univ, Dept Elect & Comp Engn, Houston, TX 77005 USA
基金
中国国家自然科学基金;
关键词
Optical gas sensor; Fabry-Perot filter detector; Multi-gas detection; INTERBAND CASCADE LASER; NITRIC-OXIDE; ABSORPTION-SPECTROSCOPY; SENSOR; METHANE;
D O I
10.1016/j.saa.2019.03.025
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
We demonstrated a versatile and innovative gas sensing system based on a Fabry-Perot (FP) filter detector, which operates in the spectral range from 3.1 to 4.4 mu m (3226-2273 cm(-1)) with a spectral resolution of 20 nm. The developed sensor system can be used to record the entire spectrum by means of a one-time scan or, alternatively, to access selected spectral regions by using the tunable FP filter detector. A multipass cell with an effective path length of 2.5 m was implemented to improve the detection sensitivity. The spectra of methane, formaldehyde and carbon dioxide were simultaneously measured, with detection limits of 200 ppm, 900 ppm and 20 ppm, respectively. A seven-day continuous measurement for indoor carbon dioxide gas was carried out demonstrating the stability and robustness of the reported sensor system. (C) 2019 Elsevier B.V. All rights reserved.
引用
收藏
页码:154 / 160
页数:7
相关论文
共 42 条
[1]   Validation of Online Monitoring of PFC by QCL with FTIR Spectroscopy [J].
Aarhaug, Thor A. ;
Ferber, Alain ;
Gaertner, Heiko ;
Kolas, Steinar ;
Ryman, Sven Olof ;
Geiser, Peter .
LIGHT METALS 2018, 2018, :1487-1493
[2]   Mid-infrared Fourier transform spectroscopy with a broadband frequency comb [J].
Adler, Florian ;
Maslowski, Piotr ;
Foltynowicz, Aleksandra ;
Cossel, Kevin C. ;
Briles, Travis C. ;
Hartl, Ingmar ;
Ye, Jun .
OPTICS EXPRESS, 2010, 18 (21) :21861-21872
[3]  
Antila J., 2014, ENCY ANAL CHEM, P1, DOI DOI 10.1002/9780470027318.A9376
[4]   Mid-infrared quantum cascade laser based off-axis integrated cavity output spectroscopy for biogenic nitric oxide detection [J].
Bakhirkin, YA ;
Kosterev, AA ;
Roller, C ;
Curl, RF ;
Tittel, FK .
APPLIED OPTICS, 2004, 43 (11) :2257-2266
[5]   Simultaneous atmospheric nitrous oxide, methane and water vapor detection with a single continuous wave quantum cascade laser [J].
Cao, Yingchun ;
Sanchez, Nancy P. ;
Jiang, Wenzhe ;
Griffin, Robert J. ;
Xie, Feng ;
Hughes, Lawrence C. ;
Zah, Chung-en ;
Tittel, Frank K. .
OPTICS EXPRESS, 2015, 23 (03) :2121-2132
[6]   A Trace Carbon Monoxide Sensor Based on Differential Absorption Spectroscopy Using Mid-Infrared Quantum Cascade Laser [J].
Chen, Chen ;
Ren, Qiang ;
Piao, Heng ;
Wang, Peng ;
Wang, Yanzhang .
MICROMACHINES, 2018, 9 (12)
[7]   Quantum cascade lasers in chemical physics [J].
Curl, Robert F. ;
Capasso, Federico ;
Gmachl, Claire ;
Kosterev, Anatoliy A. ;
McManus, Barry ;
Lewicki, Rafal ;
Pusharsky, Michael ;
Wysocki, Gerard ;
Tittel, Frank K. .
CHEMICAL PHYSICS LETTERS, 2010, 487 (1-3) :1-18
[8]   Real-Time and Simultaneous Monitoring of NO, NO2, and N2O Using Substrate-Integrated Hollow Waveguides Coupled to a Compact Fourier Transform Infrared (FT-IR) Spectrometer [J].
da Silveira Petruci, Joao Flavio ;
Tuetuencue, Erhan ;
Cardoso, Arnaldo Alves ;
Mizaikoff, Boris .
APPLIED SPECTROSCOPY, 2019, 73 (01) :98-103
[9]   Ultra-sensitive carbon monoxide detection by using EC-QCL based quartz-enhanced photoacoustic spectroscopy [J].
Dong, L. ;
Lewicki, R. ;
Liu, K. ;
Buerki, P. R. ;
Weida, M. J. ;
Tittel, F. K. .
APPLIED PHYSICS B-LASERS AND OPTICS, 2012, 107 (02) :275-283
[10]   Compact TDLAS based sensor design using interband cascade lasers for mid-IR trace gas sensing [J].
Dong, Lei ;
Tittel, Frank K. ;
Li, Chunguang ;
Sanchez, Nancy P. ;
Wu, Hongpeng ;
Zheng, Chuantao ;
Yu, Yajun ;
Sampaolo, Angelo ;
Griffin, Robert J. .
OPTICS EXPRESS, 2016, 24 (06) :A528-A535