Long-term outcome of pulmonary vein isolation in patients with paroxysmal atrial fibrillation and Brugada syndrome

被引:9
|
作者
Mugnai, Giacomo [1 ]
Hunuk, Burak [1 ]
Stroker, Erwin [1 ]
Ruggiero, Diego [1 ]
Coutino-Moreno, Hugo Enrique [1 ]
Takarada, Ken [1 ]
De Regibus, Valentina [1 ]
Choudhury, Rajin [1 ]
de Torres, Juan Pablo Abugattas [1 ]
Moran, Darragh [1 ]
Iacopino, Saverio [2 ]
Filannino, Pasquale [2 ]
Conte, Giulio [1 ]
Sieira, Juan [1 ]
Poelaert, Jan [3 ]
Beckers, Stefan [3 ]
Brugada, Pedro [1 ]
de Asmundis, Carlo [1 ]
Chierchia, Gian-Battista [1 ]
机构
[1] UZ Brussel, Heart Rhythm Management Ctr, VUB Laarbeklaan 101, B-1090 Brussels, Belgium
[2] Maria Cecilia Hosp, Electrophysiol Unit, Via Corriera 1, I-48033 Cotignola, RA, Italy
[3] UZ Brussel, Dept Anaesthesiol, VUB Laarbeklaan 101, B-1090 Brussels, Belgium
来源
EUROPACE | 2018年 / 20卷 / 03期
关键词
Atrial fibrillation; Brugada syndrome; Pulmonary vein isolation; Cryoballoon; Radiofrequency; Inappropriate shock; IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR; HEART-RHYTHM-ASSOCIATION; FOLLOW-UP; CRYOBALLOON ABLATION; CATHETER ABLATION; PREVALENCE; MANAGEMENT; EFFICACY; 1ST;
D O I
10.1093/europace/euw428
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The therapeutical management of atrial fibrillation (AF) in the setting of Brugada syndrome (BS) might be challenging as many antiarrhythmic drugs (AADs) with sodium channel blocking properties might lead to to the development of ventricular arrhythmias. This study sought to evaluate the clinical outcome in a consecutive series of patients with BS having undergone pulmonary vein (PV) isolation by means of radiofrequency (RF) or cryoballoon (CB) ablation and the efficacy of catheter ablation for preventing inappropriate interventions delivered by implantable cardioverter defibrillators (ICD) on a 3-year follow up. Twenty-three consecutive patients with BS (13 males; mean age was 47 +/- 18 years) having undergone PV isolation for drug-resistant paroxysmal AF were enrolled. Eleven patients (48%) had an ICD implanted of whom four had inappropriate shocks secondary to rapid AF. Over a mean follow-up period of 35.0 +/- 25.4 months (median 36 months) the freedom from AF recurrence after the index PV isolation procedure was 74% without AADs. Patients with inappropriate ICD interventions for AF did not present futher ICD shocks after AF ablation. No major complications occurred. Catheter ablation is a valid therapeutic choice for patients with BS and paroxysmal AF considering the high success rates, the limitations of the AADs and the safety of the procedure, and it should be taken into consideration especially in those patients presenting inappropriate ICD shocks due to rapid AF.
引用
收藏
页码:548 / 554
页数:7
相关论文
共 50 条
  • [41] Long-term Outcome and the Mechanisms of Pulmonary Antrum Radial-linear Ablation in Patients With Paroxysmal Atrial Fibrillation
    Zhao, Xue
    Hu, Jianqiang
    Huang, Yan
    Xu, Yawei
    Zhang, Yanzhou
    Gong, Hui
    Liu, Zhenguo
    CIRCULATION, 2015, 132
  • [42] Long-term Outcome and the Mechanisms of Pulmonary Antrum Radial-linear Ablation in Patients with Paroxysmal Atrial Fibrillation
    Zhao, Xue
    Liao, Dening
    Guo, Xingui
    Xu, Yawei
    Zhang, Yanzhou
    Gong, Hui
    Liu, Zhenguo
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 66 (16) : C183 - C183
  • [43] Long-term outcome and the mechanisms of pulmonary antrum radial-linear ablation in patients with paroxysmal atrial fibrillation
    Zhao, X.
    Zhu, Y. X.
    Zhang, J. Y.
    Liao, D. N.
    Hu, J. Q.
    Lu, W. L.
    Huang, Y.
    Zhang, Y. Z.
    Gong, H.
    Liu, Z. G.
    EUROPEAN HEART JOURNAL, 2015, 36 : 736 - 736
  • [44] The Pulmonary Vein Isolation is the Primary Therapy for paroxysmal Atrial Fibrillation
    Gonska, Bernd-Dieter
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 2017, 142 (10) : 763 - 764
  • [45] LONG TERM EFFICACY FOR CRYOBALLOON PULMONARY VEIN ISOLATION IN ATRIAL FIBRILLATION
    Guhl, Emily
    Barakat, Amr
    Medhekar, Ankit
    Pham, Richard
    Bazaz, Raveen
    Wang, Norman
    Voigt, Andrew
    Kancharla, Krishna
    Bhonsale, Aditya
    Estes, N. A. Mark
    Saba, Samir F.
    Jain, Sandeep
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2020, 75 (11) : 276 - 276
  • [46] Occurrence of persistent atrial fibrillation after pulmonary vein isolation for paroxysmal atrial fibrillation
    Rousseva, E.
    EUROPEAN HEART JOURNAL, 2017, 38 : 176 - 177
  • [47] Impact of Pulmonary Vein Anatomy on Long-term Outcome of Cryoballoon Ablation for Atrial Fibrillation
    Huang, Shang-wei
    Jin, Qi
    Zhang, Ning
    Ling, Tian-you
    Pan, Wen-qi
    Lin, Chang-jian
    Luo, Qing-zhi
    Han, Yan-xin
    Wu, Li-qun
    CURRENT MEDICAL SCIENCE, 2018, 38 (02) : 259 - 267
  • [48] Long-term clinical outcome of right atrial ablation for paroxysmal atrial fibrillation
    Tondo, C
    Riva, SRS
    Carbucicchio, CCC
    Apostolo, AAA
    Fassini, GFG
    Della Bella, PDBP
    EUROPEAN HEART JOURNAL, 2000, 21 : 673 - 673
  • [49] Impact of Pulmonary Vein Anatomy on Long-term Outcome of Cryoballoon Ablation for Atrial Fibrillation
    Shang-wei Huang
    Qi Jin
    Ning Zhang
    Tian-you Ling
    Wen-qi Pan
    Chang-jian Lin
    Qing-zhi Luo
    Yan-xin Han
    Li-qun Wu
    Current Medical Science, 2018, 38 : 259 - 267
  • [50] Long-term outcome of paroxysmal atrial fibrillation catheter ablation with and without pulmonary vein dormant conduction after adenosine challenge
    Skala, Tomas
    Precek, Jan
    Hutyra, Martin
    Moravec, Ondrej
    Tudos, Zbynek
    Skalova, Jitka
    Klementova, Olga
    Antonicka, Andrea
    Zapletalova, Jana
    Taborsky, Milos
    BIOMEDICAL PAPERS-OLOMOUC, 2020, 164 (02): : 147 - 153