Long-term outcome of pulmonary vein isolation in patients with paroxysmal atrial fibrillation and Brugada syndrome

被引:9
|
作者
Mugnai, Giacomo [1 ]
Hunuk, Burak [1 ]
Stroker, Erwin [1 ]
Ruggiero, Diego [1 ]
Coutino-Moreno, Hugo Enrique [1 ]
Takarada, Ken [1 ]
De Regibus, Valentina [1 ]
Choudhury, Rajin [1 ]
de Torres, Juan Pablo Abugattas [1 ]
Moran, Darragh [1 ]
Iacopino, Saverio [2 ]
Filannino, Pasquale [2 ]
Conte, Giulio [1 ]
Sieira, Juan [1 ]
Poelaert, Jan [3 ]
Beckers, Stefan [3 ]
Brugada, Pedro [1 ]
de Asmundis, Carlo [1 ]
Chierchia, Gian-Battista [1 ]
机构
[1] UZ Brussel, Heart Rhythm Management Ctr, VUB Laarbeklaan 101, B-1090 Brussels, Belgium
[2] Maria Cecilia Hosp, Electrophysiol Unit, Via Corriera 1, I-48033 Cotignola, RA, Italy
[3] UZ Brussel, Dept Anaesthesiol, VUB Laarbeklaan 101, B-1090 Brussels, Belgium
来源
EUROPACE | 2018年 / 20卷 / 03期
关键词
Atrial fibrillation; Brugada syndrome; Pulmonary vein isolation; Cryoballoon; Radiofrequency; Inappropriate shock; IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR; HEART-RHYTHM-ASSOCIATION; FOLLOW-UP; CRYOBALLOON ABLATION; CATHETER ABLATION; PREVALENCE; MANAGEMENT; EFFICACY; 1ST;
D O I
10.1093/europace/euw428
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The therapeutical management of atrial fibrillation (AF) in the setting of Brugada syndrome (BS) might be challenging as many antiarrhythmic drugs (AADs) with sodium channel blocking properties might lead to to the development of ventricular arrhythmias. This study sought to evaluate the clinical outcome in a consecutive series of patients with BS having undergone pulmonary vein (PV) isolation by means of radiofrequency (RF) or cryoballoon (CB) ablation and the efficacy of catheter ablation for preventing inappropriate interventions delivered by implantable cardioverter defibrillators (ICD) on a 3-year follow up. Twenty-three consecutive patients with BS (13 males; mean age was 47 +/- 18 years) having undergone PV isolation for drug-resistant paroxysmal AF were enrolled. Eleven patients (48%) had an ICD implanted of whom four had inappropriate shocks secondary to rapid AF. Over a mean follow-up period of 35.0 +/- 25.4 months (median 36 months) the freedom from AF recurrence after the index PV isolation procedure was 74% without AADs. Patients with inappropriate ICD interventions for AF did not present futher ICD shocks after AF ablation. No major complications occurred. Catheter ablation is a valid therapeutic choice for patients with BS and paroxysmal AF considering the high success rates, the limitations of the AADs and the safety of the procedure, and it should be taken into consideration especially in those patients presenting inappropriate ICD shocks due to rapid AF.
引用
收藏
页码:548 / 554
页数:7
相关论文
共 50 条
  • [1] Long-Term Outcomes of Pulmonary Vein Isolation in Patients With Brugada Syndrome and Paroxysmal Atrial Fibrillation
    Bisignani, Antonio
    Conte, Giulio
    Pannone, Luigi
    Sieira, Juan
    Del Monte, Alvise
    Lipartiti, Felicia
    Bala, Gezim
    Miraglia, Vincenzo
    Monaco, Cinzia
    Stroker, Erwin
    Overeinder, Ingrid
    Almorad, Alexandre
    Gauthey, Anais
    Franchetti Pardo, Livia
    Raes, Matthias
    Detriche, Olivier
    Brugada, Pedro
    Auricchio, Angelo
    Chierchia, Gian-Battista
    de Asmundis, Carlo
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2022, 11 (15):
  • [2] Efficacy of pulmonary vein isolation in paroxysmal atrial fibrillation patients with a Brugada electrocardiogram
    Yamada, Takumi
    Yoshida, Yukihiko
    Tsuboi, Naoya
    Murakami, Yoshimasa
    Okada, Taro
    McElderry, Hugh T.
    Yoshida, Naoki
    Doppalapudi, Harish
    Epstein, Andrew E.
    Plumb, Vance J.
    Inden, Yasuya
    Murohara, Toyoaki
    Kay, G. Neal
    CIRCULATION JOURNAL, 2008, 72 (02) : 281 - 286
  • [3] Long-term outcomes of cryoballoon pulmonary vein isolation for paroxysmal and persistent atrial fibrillation in Chinese patients
    Chan, Ngai-Yin
    Choy, Chi-Chung
    Yuen, Ho-Chuen
    Chow, Hoi-Fan
    Fong, Ho-Fai
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2020, 57 (03) : 425 - 434
  • [4] Long-term results of surgical minimally invasive pulmonary vein isolation for paroxysmal lone atrial fibrillation
    De Maat, Gijs E.
    Pozzoli, Alberto
    Scholten, Marcoen F.
    Van Gelder, Isabelle C.
    Blaauw, Yuri
    Mulder, Bart A.
    Della Bella, Paolo
    Alfieri, Ottavio R.
    Benussi, Stefano
    Mariani, Massimo A.
    EUROPACE, 2015, 17 (05): : 747 - 752
  • [5] Pulmonary vein anatomy and long-term outcome after multi-electrode pulmonary vein isolation with phased radiofrequency energy for paroxysmal atrial fibrillation
    Mulder, Anton A. W.
    Wijffels, Maurits C. E. F.
    Wever, Eric F. D.
    Boersma, Lucas V. A.
    EUROPACE, 2011, 13 (11): : 1557 - 1561
  • [6] Long-term outcomes of cryoballoon pulmonary vein isolation for paroxysmal and persistent atrial fibrillation in Chinese patients
    Ngai-Yin Chan
    Chi-Chung Choy
    Ho-Chuen Yuen
    Hoi-Fan Chow
    Ho-Fai Fong
    Journal of Interventional Cardiac Electrophysiology, 2020, 57 : 425 - 434
  • [7] Cryoballoon ablation for pulmonary vein isolation in patients with paroxysmal atrial fibrillation
    Kuehne, Michael
    Schaer, Beat
    Ammann, Peter
    Suter, Yves
    Osswald, Stefan
    Sticherling, Christian
    SWISS MEDICAL WEEKLY, 2010, 140 (15-16) : 214 - 221
  • [8] Long-term clinical outcome following pulmonary vein isolation with high-intensity focused ultrasound balloon catheters in patients with paroxysmal atrial fibrillation
    Metzner, Andreas
    Chun, K. R. Julian
    Neven, Kars
    Fuernkranz, Alexander
    Ouyang, Feifan
    Antz, Matthias
    Tilz, Roland
    Zerm, Thomas
    Koektuerk, Buelent
    Wissner, Eric
    Koester, Ilka
    Ernst, Sabine
    Boczor, Sigrid
    Kuck, Karl-Heinz
    Schmidt, Boris
    EUROPACE, 2010, 12 (02): : 188 - 193
  • [9] Pulmonary Vein Antral Isolation for Paroxysmal Atrial Fibrillation: Results from Long-Term Follow-Up
    Medi, C.
    Sparks, P. B.
    Morton, J. B.
    Kistler, P. M.
    Halloran, K.
    Rosso, R.
    Vohra, J. K.
    Kumar, S.
    Kalman, J. M.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2011, 22 (02) : 137 - 141
  • [10] Pulmonary vein isolation: The impact of pulmonary venous anatomy on long-term outcome of catheter ablation for paroxysmal atrial fibrillation
    McLellan, Alex J. A.
    Ling, Liang-han
    Ruggiero, Diego
    Wong, Michael C. G.
    Walters, Tomos E.
    Nisbet, Ashley
    Shetty, Anoop K.
    Azzopardi, Sonia
    Taylor, Andrew J.
    Morton, Joseph B.
    Kalman, Jonathan M.
    Kistler, Peter M.
    HEART RHYTHM, 2014, 11 (04) : 549 - 556