Elaboration of screen-printed microelectrodes working as generator/collector and their use in a flow cell system

被引:12
作者
Rene, Alice [2 ]
Cugnet, Cyril [1 ]
Hauchard, Didier [2 ]
Authier, Laurent [1 ]
机构
[1] Univ Pau & Pays Adour, LCABIE, UMR CNRS 5254, IPREM, F-64053 Pau 9, France
[2] ENSCR, UMR CNRS 6226, Lab Sci Chim Rennes, F-35708 Rennes 7, France
关键词
Microelectrode; Generator/collector; Screen-printing; Dual-electrode; Flow cell; CAPILLARY-ELECTROPHORESIS-ELECTROCHEMISTRY; DUAL-ELECTRODE DETECTION; LIQUID-CHROMATOGRAPHY; MICROBAND ELECTRODES; AMPEROMETRIC DETECTION; INJECTION ANALYSIS; BAND ELECTRODES; FABRICATION; ULTRAMICROELECTRODES; VOLTAMMETRY;
D O I
10.1016/j.snb.2012.07.109
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple and cheap method has been developed to fabricate generator/collector microelectrodes. The elaboration of these electrodes consists in the deposit of consecutive layers of conductive ink and insulator by screen-printing. The two resulting working surfaces (microbands) are situated on the edge of the sensor and are separated by a very thin layer of insulator (17 mu m). These microbancls may be individually polarized at different potentials in order to generate a species at one of them and detect it at the other one. Cyclic voltammetry has been used to test and characterize the two working surfaces. The capacity of these dual-electrodes for working as generator/collector sensors is demonstrated by recording the generated and collected currents by chronoamperometry with a bipotentiostat. The collected current is about 30% of the generated current. These sensors have been adapted to a flow cell, allowing detection of sub-nanomoles of solute. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:225 / 230
页数:6
相关论文
共 38 条
  • [11] Dual-electrode microfluidic cell for characterizing electrocatalysts
    Dumitrescu, Ioana
    Yancey, David F.
    Crooks, Richard M.
    [J]. LAB ON A CHIP, 2012, 12 (05) : 986 - 993
  • [12] ULTRAMICROELECTRODES IN ELECTROCHEMISTRY
    HEINZE, J
    [J]. ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 1993, 32 (09) : 1268 - 1288
  • [13] ENZYME DUAL-ELECTRODE FOR ANALYTE DETERMINATION
    Hill, HAO
    KLEIN, NA
    PSALTI, ISM
    WALTON, NJ
    [J]. ANALYTICAL CHEMISTRY, 1989, 61 (19) : 2200 - 2206
  • [14] Postcolumn reaction detection with dual-electrode capillary electrophoresis-electrochemistry and electrogenerated bromine
    Holland, LA
    Lunte, SM
    [J]. ANALYTICAL CHEMISTRY, 1999, 71 (02) : 407 - 412
  • [15] Holland LA, 1998, ANAL COMMUN, V35, p1H
  • [16] Holland LA, 1999, ELECTROANAL, V11, P327, DOI 10.1002/(SICI)1521-4109(199905)11:5<327::AID-ELAN327>3.0.CO
  • [17] 2-G
  • [18] Voltammetric behavior of nitrazepam and its determination in serum using liquid chromatography with redox mode dual-electrode detection
    Honeychurch, KC
    Smith, GC
    Hart, JP
    [J]. ANALYTICAL CHEMISTRY, 2006, 78 (02) : 416 - 423
  • [19] Determination of phylloquinone in vegetables, fruits, and berries by high-performance liquid chromatography with electrochemical detection
    Koivu, TJ
    Piironen, VI
    Henttonen, SK
    Mattila, PH
    [J]. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1997, 45 (12) : 4644 - 4649
  • [20] Simple Flow Injection Analysis System for Simultaneous Determination of Phenolic Antioxidants with Multiple Pulse Amperometric Detection at a Boron-Doped Diamond Electrode
    Medeiros, Roberta Antigo
    Lourencao, Bruna Claudia
    Rocha-Filho, Romeu Cardozo
    Fatibello-Filho, Orlando
    [J]. ANALYTICAL CHEMISTRY, 2010, 82 (20) : 8658 - 8663