Evaluation of spontaneous third ventriculostomy by three-dimensional sampling perfection with application-optimized contrasts using different flip-angle evolutions (3D-SPACE) sequence by 3T MR imaging: Preliminary results with variant flip-angle mode

被引:20
作者
Algin, Oktay [1 ]
Turkbey, Baris [2 ]
Ozmen, Evrim [1 ]
Ocakoglu, Gokhan [3 ]
Karaoglanoglu, Mustafa [1 ]
Arslan, Halil [1 ]
机构
[1] Ataturk Training & Res Hosp, Dept Radiol, TR-06050 Ankara, Turkey
[2] NCI, NIH, Bethesda, MD 20892 USA
[3] Uludag Univ, Biostat Dept, Fac Med, Gorukle, Bursa, Turkey
关键词
Spontaneous third ventriculostomy; Obstructive hydrocephalus; Magnetic resonance imaging; 3D-SPACE; Phase-contrast cine MRI; SINGLE-SLAB; CISTERNOGRAPHY; 3D-CISS; SPACE; 3D;
D O I
10.1016/j.neurad.2011.12.003
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Purpose: This prospective study aimed to evaluate the use of three-dimensional sampling perfection with application-optimized contrasts using different flip-angle evolutions (3D-SPACE) in the diagnosis of spontaneous third ventriculostomy (STY) and to compare it with phase-contrast cine magnetic resonance imaging (PC-MRI). Methods: PC-MRI and 3D-SPACE images were obtained in 15 patients with hydrocephalus for evaluation of STY as well as in 10 control cases. The presence of STY was evaluated visually by two experienced radiologists on both PC-MRI and 3D-SPACE images, and the results were statistically compared. Results: There was a strong correlation between PC-MRI and SPACE scores for both readers (correlation coefficient [r] = 0.784; P = 0.001). There was also a good correlation between PC-MRI scores and consensus-based results. Interobserver reliabilities were strong for all STY scores. In addition, there was excellent correlation between 3D-SPACE scores and consensus-based results (first reader's kappa value: 0.87; second reader's kappa value: 1). Conclusion: 3D-SPACE can provide morphological physiological information for the evaluation of STY with no need for additional PC-MRI analysis or other sequences. As a non-invasive test, it can also be included among the first line of choices of MRI sequences for patients with obstructive hydrocephalus. (C) 2011 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:11 / 18
页数:8
相关论文
共 24 条
[1]   Intrathecal Gadolinium-Enhanced MR Cisternography: A Comprehensive Review [J].
Algin, O. ;
Turkbey, B. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2013, 34 (01) :14-22
[2]   Evaluation of Aqueductal Stenosis by 3D Sampling Perfection with Application-Optimized Contrasts Using Different Flip Angle Evolutions Sequence: Preliminary Results with 3T MR Imaging [J].
Algin, O. ;
Turkbey, B. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2012, 33 (04) :740-746
[3]   Phase-contrast MRI and 3D-CISS versus contrast-enhanced MR cisternography for the detection of spontaneous third ventriculostomy [J].
Algin, O. ;
Hakyemez, B. ;
Parlak, M. .
JOURNAL OF NEURORADIOLOGY, 2011, 38 (02) :98-104
[4]   The contribution of 3D-CISS and contrast-enhanced MR cisternography in detecting cerebrospinal fluid leak in patients with rhinorrhoea [J].
Algin, O. ;
Hakyemez, B. ;
Gokalp, G. ;
Ozcan, T. ;
Korfali, E. ;
Parlak, M. .
BRITISH JOURNAL OF RADIOLOGY, 2010, 83 (987) :225-232
[5]   Phase-contrast MRI and 3D-CISS versus contrast-enhanced MR cisternography on the evaluation of the aqueductal stenosis [J].
Algin, Oktay ;
Hakyemez, Bahattin ;
Parlak, Mufit .
NEURORADIOLOGY, 2010, 52 (02) :99-108
[6]   The Efficiency of PC-MRI in Diagnosis of Normal Pressure Hydrocephalus and Prediction of Shunt Response [J].
Algin, Oktay ;
Hakyemez, Bahattin ;
Parlak, Mufit .
ACADEMIC RADIOLOGY, 2010, 17 (02) :181-187
[7]   Role of complex hydrocephalus in unsuccessful endoscopic third ventriculostomy [J].
Algin, Oktay .
CHILDS NERVOUS SYSTEM, 2010, 26 (01) :3-4
[8]  
Altman DG, 1990, PRACTICAL STAT MED R, DOI DOI 10.1201/9780429258589
[9]   Phase-contrast cine MRI revealing en valve mechanism in spontaneous third ventriculostomy: Report of a case and literature review [J].
Bailey, Ariel ;
Pipitone, Nicolo ;
Zuccoli, Giulio .
CLINICAL NEUROLOGY AND NEUROSURGERY, 2010, 112 (09) :817-820
[10]   Detection of lesions in multiple sclerosis by 2D FLAIR and single-slab 3D FLAIR sequences at 3.0 T: initial results [J].
Bink, A ;
Schmitt, M ;
Gaa, J ;
Mugler, JP ;
Lanfermann, H ;
Zanella, FE .
EUROPEAN RADIOLOGY, 2006, 16 (05) :1104-1110