Fire Performance of External Thermal Insulation Composite System (ETICS) Facades with Expanded Polystyrene (EPS) Insulation and Thin Rendering

被引:26
|
作者
Hajdukovic, Milan [1 ]
Knez, Natasa [1 ]
Kolsek, Jerneja [1 ]
Knez, Friderik [2 ]
机构
[1] ZAG Slovenian Natl Bldg & Civil Engn Inst, Fire Lab & Fire Engn, Dimiceva 12, Ljubljana 1000, Slovenia
[2] ZAG Slovenian Natl Bldg & Civil Engn Inst, Lab Efficient Use Energy & Acoust, Dimiceva 12, Ljubljana 1000, Slovenia
关键词
Fire; Large-scale experiment; EPS ETICS facade; Render cracking; Numerical modelling; Expanded polystyrene; THERMODYNAMIC PROPERTIES; LINEAR MACROMOLECULES; VENTING FLAMES; HEAT-CAPACITY; PLUME; SCALE; TESTS;
D O I
10.1007/s10694-016-0622-2
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
External Thermal Insulation Composite System (ETICS) facades with expanded polystyrene (EPS) insulation and thin rendering are applied frequently in buildings. Considering high combustibility of EPS, with these facades concerns also arise regarding spread of a possible fire between neighbouring compartments of high-rise buildings. Fire tests of two large-scale facades were performed to study two parameters presumably influencing significantly the fires of such facades in real-life settings, i.e. incident heat flux upon the facade's surface (IHFFS) and damage of the facade's render (the latter being a consequence of poor or unfinished construction work, ageing or fire-induced thermal strain). The first facade was rendered fully and was exposed to moderately-fast increasing IHFFS. In the second (partially unrendered) facade case the IHFFS progressed faster. The facade flame body (temperatures and shape) was monitored by thermocouples, photo and video cameras. For detection of melting of EPS and internal burning, thermocameras were used within the facades areas outside the visible plume. In the plume zone, however, a group of thermocouples was embedded inside EPS and the shapes (plateaus and slopes) of the collected time-temperature graphs were observed for these purposes. The IHFFS imposed on the facades during fire testing were estimated by numerical calculations. In both cases the first pronounced render crack was evolved at the estimated average between-windows IHFFS of around 30 kW/m and was followed by internal burning of EPS. While the latter did not seem to spread across the facade for the fully-rendered facade, a fast fire spread was detected for the second specimen.
引用
收藏
页码:173 / 209
页数:37
相关论文
共 50 条
  • [31] Methodological framework to assess the significance of External Thermal Insulation Composite System (ETICS) on-site activities
    Sulakatko, Virgo
    Lill, Irene
    Witt, Emlyn
    SUSTAINABLE BUILT ENVIRONMENT TALLINN AND HELSINKI CONFERENCE SBE16 BUILD GREEN AND RENOVATE DEEP, 2016, 96 : 446 - 454
  • [32] Thermal and sound insulation performance assessment of vacuum insulated composite insulation panels for building facades
    O'Flaherty, Fin
    Alam, Mahmood
    ADVANCES IN BUILDING ENERGY RESEARCH, 2021, 15 (03) : 270 - 290
  • [33] Recycled EPS (expanded polystyrene) from food's packaging as a thermal insulation of roofs
    Medeiros, DS
    Marinho, GS
    Energy-Efficient, Cost-Effective and Environmentally-Sustainable Systems and Processes, Vols 1-3, 2004, : 233 - 240
  • [34] Hygrothermal behaviour of external thermal insulation composite systems (ETICS) to withstand biological colonisation
    Parrachaa, Joao L.
    Veiga, Rosario
    Gomes, M. Gloria
    Flores-Colen, Ines
    Nunes, Lina
    JOURNAL OF BUILDING ENGINEERING, 2024, 86
  • [35] Analysis of on-site construction processes for effective external thermal insulation composite system (ETICS) installation
    Sulakatko, Virgo
    Lill, Irene
    Liisma, Eneli
    8TH NORDIC CONFERENCE ON CONSTRUCTION ECONOMICS AND ORGANIZATION, 2015, 21 : 297 - 305
  • [36] Investigations of the performance of facades made of ETICS with polystyrene under external fire exposure and fire safety measures for their improvement
    Kotthoff, Ingolf
    Hauswaldt, Sebastian
    Riese, Olaf
    Riemesch-Speer, Jan
    2ND INTERNATIONAL SEMINAR FOR FIRE SAFETY OF FACADES, 2016, 46
  • [37] Comparative study of Chinese, European and ISO external thermal insulation composite system (ETICS) standards and technical recommendations
    Xu, Hongtao
    Wang, Hao
    Huo, Qiannan
    Qin, Yue
    Zhou, Hui
    JOURNAL OF BUILDING ENGINEERING, 2023, 68
  • [38] Increasing Construction Quality of External Thermal Insulation Composite System (ETICS) by Revealing on-site Degradation Factors
    Sulakatko, Virgo
    Liisma, Eneli
    Soekov, Erki
    SUSTAINABLE SYNERGIES FROM BUILDINGS TO THE URBAN SCALE, 2017, 38 : 765 - 772
  • [39] Fire Safety of External Thermal Insulation Systems (ETICS) in the Aspect of Sustainable Use of Natural Resources
    Niziurska, Malgorzata
    Wieczorek, Michal
    Borkowicz, Klaudiusz
    SUSTAINABILITY, 2022, 14 (03)
  • [40] Effect of plaster thickness on performance of external thermal insulation cladding systems (ETICS) in buildings
    Uygunoglu, Tayfun
    Ozguven, Sevcan
    Calis, Metehan
    CONSTRUCTION AND BUILDING MATERIALS, 2016, 122 : 496 - 504