Fire Performance of External Thermal Insulation Composite System (ETICS) Facades with Expanded Polystyrene (EPS) Insulation and Thin Rendering

被引:26
|
作者
Hajdukovic, Milan [1 ]
Knez, Natasa [1 ]
Kolsek, Jerneja [1 ]
Knez, Friderik [2 ]
机构
[1] ZAG Slovenian Natl Bldg & Civil Engn Inst, Fire Lab & Fire Engn, Dimiceva 12, Ljubljana 1000, Slovenia
[2] ZAG Slovenian Natl Bldg & Civil Engn Inst, Lab Efficient Use Energy & Acoust, Dimiceva 12, Ljubljana 1000, Slovenia
关键词
Fire; Large-scale experiment; EPS ETICS facade; Render cracking; Numerical modelling; Expanded polystyrene; THERMODYNAMIC PROPERTIES; LINEAR MACROMOLECULES; VENTING FLAMES; HEAT-CAPACITY; PLUME; SCALE; TESTS;
D O I
10.1007/s10694-016-0622-2
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
External Thermal Insulation Composite System (ETICS) facades with expanded polystyrene (EPS) insulation and thin rendering are applied frequently in buildings. Considering high combustibility of EPS, with these facades concerns also arise regarding spread of a possible fire between neighbouring compartments of high-rise buildings. Fire tests of two large-scale facades were performed to study two parameters presumably influencing significantly the fires of such facades in real-life settings, i.e. incident heat flux upon the facade's surface (IHFFS) and damage of the facade's render (the latter being a consequence of poor or unfinished construction work, ageing or fire-induced thermal strain). The first facade was rendered fully and was exposed to moderately-fast increasing IHFFS. In the second (partially unrendered) facade case the IHFFS progressed faster. The facade flame body (temperatures and shape) was monitored by thermocouples, photo and video cameras. For detection of melting of EPS and internal burning, thermocameras were used within the facades areas outside the visible plume. In the plume zone, however, a group of thermocouples was embedded inside EPS and the shapes (plateaus and slopes) of the collected time-temperature graphs were observed for these purposes. The IHFFS imposed on the facades during fire testing were estimated by numerical calculations. In both cases the first pronounced render crack was evolved at the estimated average between-windows IHFFS of around 30 kW/m and was followed by internal burning of EPS. While the latter did not seem to spread across the facade for the fully-rendered facade, a fast fire spread was detected for the second specimen.
引用
收藏
页码:173 / 209
页数:37
相关论文
共 50 条
  • [21] Lightweight structural cement composites with expanded polystyrene (EPS) for enhanced thermal insulation
    Dixit, Anjaneya
    Pang, Sze Dai
    Kang, Sung-Hoon
    Moon, Juhyuk
    CEMENT & CONCRETE COMPOSITES, 2019, 102 : 185 - 197
  • [22] The Impact of Climatic Factors to the Structure of Unprotected Expanded Polystyrene External Insulation on Building (Eps)
    Mickevicius, Edgaras
    Kicaite, Asta
    Buska, Andrius
    ADVANCED CONSTRUCTION 2012, 2012, : 133 - +
  • [23] External Thermal Insulation Composite Systems (ETICS) from Industry and Academia Perspective
    Michalak, Jacek
    SUSTAINABILITY, 2021, 13 (24)
  • [24] Experimental study of the hygrothermal behaviour of External Thermal Insulation Composite Systems (ETICS)
    Barreira, Eva
    de Freitas, Vasco P.
    BUILDING AND ENVIRONMENT, 2013, 63 : 31 - 39
  • [25] Effects of opening edge treatment and EPS thickness on EPS external thermal insulation composite systems (ETICS) facade reaction-to-fire performance based on JIS A1310 standard facade fire test method
    Zhou, Biao
    Yoshioka, Hideki
    Noguchi, Takafumi
    Ando, Tatsuo
    FIRE AND MATERIALS, 2018, 42 (05) : 537 - 548
  • [26] Weatherability Studies on External Insulation Thermal System of Expanded Polystyrene Board, Polystyrene Granule and Polyurethane Foam
    Yin Xiuqin
    Li Huiqiang
    Bo Haitao
    Ke Huahu
    JOURNAL OF WUHAN UNIVERSITY OF TECHNOLOGY-MATERIALS SCIENCE EDITION, 2010, 25 (06): : 1027 - 1032
  • [27] Weatherability studies on external insulation thermal system of expanded polystyrene board, polystyrene granule and polyurethane foam
    Xiuqin Yin
    Huiqiang Li
    Haitao Bo
    Huahu Ke
    Journal of Wuhan University of Technology-Mater. Sci. Ed., 2010, 25 : 1027 - 1032
  • [29] Quality control of EPS External wall thermal Insulation System
    Ma, Xiaoqiu
    FRONTIERS OF GREEN BUILDING, MATERIALS AND CIVIL ENGINEERING, PTS 1-8, 2011, 71-78 : 4115 - 4119
  • [30] Innovative fire and water insulation foam using recycled plastic bags and expanded polystyrene (EPS)
    Fard, Parastoo Moghaddam
    Alkhansari, Maryam Gharavi
    CONSTRUCTION AND BUILDING MATERIALS, 2021, 305