Cycloid scanning for wide field optical coherence tomography endomicroscopy and angiography in vivo

被引:31
|
作者
Liang, Kaicheng [1 ]
Wang, Zhao [1 ]
Ahsen, Osman O. [1 ]
Lee, Hsiang-Chieh [1 ]
Potsaid, Benjamin M. [1 ,2 ]
Jayaraman, Vijaysekhar [3 ]
Cable, Alex [2 ]
Mashimo, Hiroshi [4 ,5 ]
Li, Xingde [6 ]
Fujimoto, James G. [1 ]
机构
[1] MIT, Dept Elect Engn & Comp Sci, Res Lab Elect, Cambridge, MA 02139 USA
[2] Thorlabs, Newton, NJ 07860 USA
[3] Praevium Res, Santa Barbara, CA 93111 USA
[4] Vet Affairs Boston Healthcare Syst, Boston, MA 02130 USA
[5] Harvard Med Sch, Boston, MA 02115 USA
[6] Johns Hopkins Univ, Dept Biomed Engn, Baltimore, MD 21218 USA
来源
OPTICA | 2018年 / 5卷 / 01期
基金
美国国家卫生研究院;
关键词
EN-FACE OCT; BARRETTS-ESOPHAGUS; ROTATIONAL DISTORTION; CAPSULE ENDOSCOPY; SPEED; MICROSCOPY; CATHETER; HISTOLOGY; PLATFORM; TRACT;
D O I
10.1364/OPTICA.5.000036
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Devices that perform wide field-of-view (FOV) precision optical scanning are important for endoscopic assessment and diagnosis of luminal organ disease such as in gastroenterology. Optical scanning for in vivo endoscopic imaging has traditionally relied on one or more proximal mechanical actuators, limiting scan accuracy and imaging speed. There is a need for rapid and precise two-dimensional (2D) microscanning technologies to enable the translation of benchtop scanning microscopies to in vivo endoscopic imaging. We demonstrate a new cycloid scanner in a tethered capsule for ultrahigh speed, side-viewing optical coherence tomography (OCT) endomicroscopy in vivo. The cycloid capsule incorporates two scanners: a piezoelectrically actuated resonant fiber scanner to perform a precision, small FOV, fast scan and a micromotor scanner to perform a wide FOV, slow scan. Together these scanners distally scan the beam circumferentially in a 2D cycloid pattern, generating an unwrapped 1 mm x 38 mm strip FOV. Sequential strip volumes can be acquired with proximal pullback to image centimeter-long regions. Using ultrahigh speed 1.3 mu m wavelength swept-source OCT at a 1.17 MHz axial scan rate, we imaged the human rectum at 3 volumes/s. Each OCT strip volume had 166 x 2322 axial scans with 8.5 mu m axial and 30 mu m transverse resolution. We further demonstrate OCT angiography at 0.5 volumes/s, producing volumetric images of vasculature. In addition to OCT applications, cycloid scanning promises to enable precision 2D optical scanning for other imaging modalities, including fluorescence confocal and nonlinear microscopy. (c) 2018 Optical Society of America
引用
收藏
页码:36 / 43
页数:8
相关论文
共 50 条
  • [21] Wide field and highly sensitive angiography based on optical coherence tomography with akinetic swept source
    Xu, Jingjiang
    Song, Shaozhen
    Wei, Wei
    Wang, Ruikang K.
    BIOMEDICAL OPTICS EXPRESS, 2017, 8 (01): : 420 - 435
  • [22] Regression of Optic Disc Neovascularization Captured on Wide-Field Optical Coherence Tomography Angiography
    Shroff, Daraius
    Kumar, Sandeep
    Gupta, Charu
    JAMA OPHTHALMOLOGY, 2022, 140 (02)
  • [23] Detection of Clinically Unsuspected Retinal Neovascularization with Wide-Field Optical Coherence Tomography Angiography
    You, Qisheng
    Guo, Yukun
    Wang, Jie
    Wei, Xiang
    Camino, Acner
    Zang, Pengxiao
    Flaxel, Christina J.
    Bailey, Steven T.
    Huang, David
    Hwang, Thomas S.
    Jia, Yali
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)
  • [24] Ultra-wide field optical coherence tomography angiography for evaluation of retinal venous occlusion
    Zhang, Qinqin
    Attaran-Rezaei, Kasra
    Wang, Ruikang K.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)
  • [25] Visualization of the Retinal Vasculature Using Wide-Field Montage Optical Coherence Tomography Angiography
    de Carlo, Talisa E.
    Salz, David A.
    Waheed, Nadia K.
    Baumal, Caroline R.
    Duker, Jay S.
    Witkin, Andre J.
    OPHTHALMIC SURGERY LASERS & IMAGING RETINA, 2015, 46 (06): : 611 - 616
  • [26] Diagnostic performance of wide-field optical coherence tomography angiography for high myopic glaucoma
    Hong, Rim Kyung
    Kim, Ji Hong
    Toh, Gyungmin
    Na, Kyeong Ik
    Seong, Mincheol
    Lee, Won June
    SCIENTIFIC REPORTS, 2024, 14 (01)
  • [27] DETECTION OF CLINICALLY UNSUSPECTED RETINAL NEOVASCULARIZATION WITH WIDE-FIELD OPTICAL COHERENCE TOMOGRAPHY ANGIOGRAPHY
    You, Qi Sheng
    Guo, Yukun
    Wang, Jie
    Wei, Xiang
    Camino, Acner
    Zang, Pengxiao
    Flaxel, Christina J.
    Bailey, Steven T.
    Huang, David
    Jia, Yali
    Hwang, Thomas S.
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2020, 40 (05): : 891 - 897
  • [28] Endoscope optical coherence tomography angiography using proximal scanning catheter
    Gao, Lei
    Song, Yuting
    Zhang, Qi
    Kong, Ruiming
    Chen, Zhuoquan
    Cao, Guogang
    Ma, Teng
    Dai, Cuixia
    OPTICS IN HEALTH CARE AND BIOMEDICAL OPTICS XI, 2021, 11900
  • [29] Optical coherence tomography angiography
    Spaide, Richard F.
    Fujimoto, James G.
    Waheed, Nadia K.
    Sadda, Srinivas R.
    Staurenghi, Giovanni
    PROGRESS IN RETINAL AND EYE RESEARCH, 2018, 64 : 1 - 55
  • [30] Optical Coherence Tomography Angiography
    Gao, Simon S.
    Jia, Yali
    Zhang, Miao
    Su, Johnny P.
    Liu, Gangjun
    Hwang, Thomas S.
    Bailey, Steven T.
    Huang, David
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (09) : OCT27 - OCT36