Cycloid scanning for wide field optical coherence tomography endomicroscopy and angiography in vivo

被引:31
|
作者
Liang, Kaicheng [1 ]
Wang, Zhao [1 ]
Ahsen, Osman O. [1 ]
Lee, Hsiang-Chieh [1 ]
Potsaid, Benjamin M. [1 ,2 ]
Jayaraman, Vijaysekhar [3 ]
Cable, Alex [2 ]
Mashimo, Hiroshi [4 ,5 ]
Li, Xingde [6 ]
Fujimoto, James G. [1 ]
机构
[1] MIT, Dept Elect Engn & Comp Sci, Res Lab Elect, Cambridge, MA 02139 USA
[2] Thorlabs, Newton, NJ 07860 USA
[3] Praevium Res, Santa Barbara, CA 93111 USA
[4] Vet Affairs Boston Healthcare Syst, Boston, MA 02130 USA
[5] Harvard Med Sch, Boston, MA 02115 USA
[6] Johns Hopkins Univ, Dept Biomed Engn, Baltimore, MD 21218 USA
来源
OPTICA | 2018年 / 5卷 / 01期
基金
美国国家卫生研究院;
关键词
EN-FACE OCT; BARRETTS-ESOPHAGUS; ROTATIONAL DISTORTION; CAPSULE ENDOSCOPY; SPEED; MICROSCOPY; CATHETER; HISTOLOGY; PLATFORM; TRACT;
D O I
10.1364/OPTICA.5.000036
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Devices that perform wide field-of-view (FOV) precision optical scanning are important for endoscopic assessment and diagnosis of luminal organ disease such as in gastroenterology. Optical scanning for in vivo endoscopic imaging has traditionally relied on one or more proximal mechanical actuators, limiting scan accuracy and imaging speed. There is a need for rapid and precise two-dimensional (2D) microscanning technologies to enable the translation of benchtop scanning microscopies to in vivo endoscopic imaging. We demonstrate a new cycloid scanner in a tethered capsule for ultrahigh speed, side-viewing optical coherence tomography (OCT) endomicroscopy in vivo. The cycloid capsule incorporates two scanners: a piezoelectrically actuated resonant fiber scanner to perform a precision, small FOV, fast scan and a micromotor scanner to perform a wide FOV, slow scan. Together these scanners distally scan the beam circumferentially in a 2D cycloid pattern, generating an unwrapped 1 mm x 38 mm strip FOV. Sequential strip volumes can be acquired with proximal pullback to image centimeter-long regions. Using ultrahigh speed 1.3 mu m wavelength swept-source OCT at a 1.17 MHz axial scan rate, we imaged the human rectum at 3 volumes/s. Each OCT strip volume had 166 x 2322 axial scans with 8.5 mu m axial and 30 mu m transverse resolution. We further demonstrate OCT angiography at 0.5 volumes/s, producing volumetric images of vasculature. In addition to OCT applications, cycloid scanning promises to enable precision 2D optical scanning for other imaging modalities, including fluorescence confocal and nonlinear microscopy. (c) 2018 Optical Society of America
引用
收藏
页码:36 / 43
页数:8
相关论文
共 50 条
  • [1] Wide Field Optical Coherence Tomography and Optical Coherence Tomography Angiography in Uveitis
    Grewal, Dilraj S.
    Agarwal, Mamta
    Munk, Marion R.
    OCULAR IMMUNOLOGY AND INFLAMMATION, 2024, 32 (01) : 105 - 115
  • [2] Wide field of view optical coherence tomography angiography
    Arain, Muzammil A.
    Schmoll, Tilman
    Qiu, Jeff
    Williams, Rick
    Bello, Simon
    Howard, Doug
    Shemonski, Nathan
    Normand, Brian
    Moghimi, Atoosa
    Straub, Jochen
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [3] Advances in wide field optical coherence tomography angiography imaging
    Kubach, Sophie
    Lewis, Warren
    Callan, Thomas
    Perez, Thomas
    Goldberg, Roger A.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [4] Handheld Optical Coherence Tomography Angiography and Ultra-Wide-Field Optical Coherence Tomography in Retinopathy of Prematurity
    Campbell, J. Peter
    Nudleman, Eric
    Yang, Jianlong
    Tan, Ou
    Chan, R. V. Paul
    Chiang, Michael F.
    Huang, David
    Liu, Gangjun
    JAMA OPHTHALMOLOGY, 2017, 135 (09) : 977 - 981
  • [5] Wide-Field Optical Coherence Tomography of the Choroid In Vivo
    Povazay, Boris
    Hermann, Boris
    Hofer, Bernd
    Kajic, Vedran
    Simpson, Elizabeth
    Bridgford, Thomas
    Drexler, Wolfgang
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2009, 50 (04) : 1856 - 1863
  • [6] Scalable wide-field optical coherence tomography-based angiography for in vivo imaging applications
    Xu, Jingjiang
    Wei, Wei
    Song, Shaozhen
    Qi, Xiaoli
    Wang, Ruikang K.
    BIOMEDICAL OPTICS EXPRESS, 2016, 7 (05): : 1905 - 1919
  • [7] Repeatability of Wide-field Optical Coherence Tomography Angiography in Normal Retina
    Eastline, Michael
    Munk, Marion R.
    Wolf, Sebastian
    Schaal, Karen B.
    Ebneter, Andreas
    Tian, Meng
    Giannakaki-Zimmermann, Helena
    Zinkernagel, Martin S.
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2019, 8 (03):
  • [8] Recent advances in wide field and ultrawide field optical coherence tomography angiography in retinochoroidal pathologies
    Kalra, Gagan
    Pichi, Francesco
    Menia, Nitin Kumar
    Shroff, Daraius
    Phasukkijwatana, Nopasak
    Aggarwal, Kanika
    Agarwal, Aniruddha
    EXPERT REVIEW OF MEDICAL DEVICES, 2021, 18 (04) : 375 - 386
  • [9] In vivo Optical Coherence Tomography Angiography of the Coronary Microcirculation
    Zhou, Yirong
    Kim, Junyoung
    Tearney, Guillermo J.
    Aguirre, Aaron D.
    CIRCULATION, 2022, 146
  • [10] Wide-field optical coherence tomography angiography for the detection of proliferative diabetic retinopathy
    Pichi, Francesco
    Smith, Scott D.
    Abboud, Emad B.
    Neri, Piergiorgio
    Woodstock, Elizabeth
    Hay, Steven
    Levine, Emily
    Baumal, Caroline R.
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2020, 258 (09) : 1901 - 1909