A biomechanical comparison of conventional versus an anatomic plate and compression bolts for fixation of intra-articular calcaneal fractures

被引:15
作者
Wang, Haili [1 ]
Yang, Zhaoxu [1 ]
Wu, Zhanpo [1 ]
Chen, Wei [1 ]
Zhang, Qi [1 ]
Li, Ming [1 ]
Li, Zhiyong [1 ]
Zhang, Yingze [1 ]
机构
[1] Hebei Med Univ, Dept Orthoped, Hosp 3, Shijiazhuang 050051, Peoples R China
关键词
calcaneal fracture; anatomic plate fixation; compression bolts; conventional screws; biomechanical testing; MINIMALLY-INVASIVE TREATMENT; INTERNAL-FIXATION; NONOPERATIVE TREATMENT; OPEN REDUCTION; LOCKING; INCISION; SCREWS; TRIAL; MODEL;
D O I
10.1007/s11596-012-0098-3
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
The purpose of this study was to compare the biomechanical stability obtained by using our technique featured an anatomical plate and compression bolts versus that of the conventional anatomic plate and cancellous screws in the fixation of intraarticular calcaneal fractures. Eighteen fresh frozen lower limbs of cadavers were used to create a reproductive Sanders type-III calcaneal fracture model by using osteotomy. The calcaneus fractures were randomly selected to be fixed either using our anatomical plate and compression bolts or conventional anatomic plate and cancellous screws. Reduction of fracture was evaluated through X radiographs. Each calcaneus was successively loaded at a frequency of 1 Hz for 1000 cycles through the talus using an increasing axial force 20 N to 200 N and 20 N to 700 N, representing the partial weight bearing and full weight bearing, respectively, and then the specimens were loaded to failure. Data extracted from the mechanical testing machine were recorded and used to test for difference in the results with the Wilcoxon signed rank test. No significant difference was found between our fixation technique and conventional technique in displacement during 20-200 N cyclic loading (P=0.06), while the anatomical plate and compression bolts showed a great lower irreversible deformation during 20-700 N cyclic loading (P=0.008). The load achieved at loss of fixation of the constructs for the two groups had significant difference: anatomic plate and compression bolts at 3839.6 +/- 152.4 N and anatomic plate and cancellous screws at 3087.3 +/- 58.9 N (P=0.008). There was no significant difference between the ultimate displacements. Our technique featured anatomical plate and compression bolts for calcaneus fracture fixation was demonstrated to provide biomechanical stability as good as or better than the conventional anatomic plate and cancellous screws under the axial loading. The study supports the mechanical viability of using our plate and compression bolts for the fixation of calcaneal fracture.
引用
收藏
页码:571 / 575
页数:5
相关论文
共 30 条
[1]   Intra-articular calcaneal fractures treated nonoperatively and followed sequentially for 2 decades [J].
Allmacher, David H. ;
Galles, Kyle S. ;
Marsh, J. L. .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2006, 20 (07) :464-469
[2]  
Badet R, 1999, REV CHIR ORTHOP, V85, P601
[3]   Operative compared with nonoperative treatment of displacedintra-articular calcaneal fractures - A prospective, randomized, controlled multicenter trial [J].
Buckley, R ;
Tough, S ;
McCormack, R ;
Pate, G ;
Leighton, R ;
Petrie, D ;
Galpin, R .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2002, 84A (10) :1733-1744
[4]   Surgical treatment of intra-articular calcaneal fractures - A review of small incision approaches [J].
Carr, JB .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2005, 19 (02) :109-117
[5]   Internal fixation of experimental intraarticular calcaneal fractures: A biomechanical analysis of two fixation methods [J].
Carr, JB ;
Tigges, RG ;
Wayne, JS ;
Earll, M .
JOURNAL OF ORTHOPAEDIC TRAUMA, 1997, 11 (06) :425-428
[6]  
Cohen M, 2001, FOOT ANKLE SURG, V2, P1819
[7]   Controversies in calcaneus fracture management: A systematic review of the literature [J].
Dhillon M.S. ;
Bali K. ;
Prabhakar S. .
MUSCULOSKELETAL SURGERY, 2011, 95 (3) :171-181
[8]   THE MECHANISM, REDUCTION TECHNIQUE, AND RESULTS IN FRACTURES OF THE OS CALCIS [J].
ESSEXLOPRESTI, P .
BRITISH JOURNAL OF SURGERY, 1952, 39 (157) :395-419
[9]   Standardized treatment of intra-articular calcaneal fractures using an oblique lateral incision and no bone graft [J].
Geel, CW ;
Flemister, AS .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2001, 50 (06) :1083-1089
[10]   Calcaneal loading during walking and running [J].
Giddings, VL ;
Beaupré, GS ;
Whalen, RT ;
Carter, DR .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2000, 32 (03) :627-634