Analysis of the velocity-induced eddy current in MFL type NDT

被引:71
作者
Park, GS [1 ]
Park, SH
机构
[1] Pusan Natl Univ, Dept Elect Engn, Pusan 609735, South Korea
[2] Korea Maritime Univ, Dept Elect Engn, Pusan 606791, South Korea
关键词
finite-element analysis; magnetic flux leakage; nondestructive testing; pipe in gas; velocity-induced eddy current;
D O I
10.1109/TMAG.2004.824717
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In magnetic flux leakage (MFL) type nondestructive testing (NDT), there could be velocity-induced eddy currents during the sensing, which might cause the distortion of the defect signals. In this paper, the distortions of the sensing signals are analyzed by using three-dimensional finite-element analysis with velocity-induced eddy currents, and then, the compensation scheme of the signal distortion is presented to obtain the pure defect signals. The presented method has been verified by experimental measurement.
引用
收藏
页码:663 / 666
页数:4
相关论文
共 8 条
  • [1] FINITE-ELEMENT CALCULATION OF MAGNETIC-FLUX LEAKAGE DETECTOR SIGNALS
    ATHERTON, DL
    DALY, MG
    [J]. NDT INTERNATIONAL, 1987, 20 (04): : 235 - 238
  • [2] CORDELL J, 1999, ALL PIGGING, P1
  • [3] CROUCH AE, 1993, GRI910365
  • [4] Haines H., 1999, PIPELINE GAS IND, V2, P49
  • [5] NESTLEROTH JB, 1996, P NACE INT ANN C EXP, P1
  • [6] Park G. S., 2001, J MAGN, V6, P31, DOI DOI 10.1109/20.996326
  • [7] IMPLEMENTATION OF HYSTERESIS CHARACTERISTICS USING THE PREISACH MODEL WITH M-B VARIABLES
    PARK, GS
    HAHN, SY
    LEE, KS
    JUNG, HK
    [J]. IEEE TRANSACTIONS ON MAGNETICS, 1993, 29 (02) : 1542 - 1545
  • [8] TANDON KK, 1997, MAT SELECTION DESIGN, P75