Analysis of Lightning Phenomena for Underground Petroleum Pipeline System

被引:5
作者
Bhumkittipich, Krischonme [1 ]
Topradith, Boonlerd [1 ]
Suwanasri, Tanapong [2 ]
机构
[1] Rajamangala Univ Technol Thanyaburi, Power & Energy Syst Res Ctr, Fac Engn, Dept Elect Engn, Klong6, Thanyaburi 12110, Pathumthani, Thailand
[2] King Mungkuts Univ Technol, Sirindhorn Int Thai German Grad Sch Engn TGGS, North Bangkok, Thailand
来源
10TH ECO-ENERGY AND MATERIALS SCIENCE AND ENGINEERING SYMPOSIUM | 2013年 / 34卷
关键词
Pipeline; Lightning; Impedance; Transient; Induced voltage;
D O I
10.1016/j.egypro.2013.06.743
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This article presents the lightning phenomena analysis for underground petroleum pipeline system and protection guideline by considering an electrical continuity after a lightning strike to the earth. The result of transient state occur on the pipeline by using mathematical program (ATP-EMTP) to simulate standard waveform 10/350 micro second which will be linked to several dimensions. This study will transform physical characteristics into electrical characteristics such as pipe metal, pipe insulator, conductors in corrosion protection circuit and earth as parameters in the analysis. The result of this simulation found that the transient voltage will rise higher if length is longer and higher than safety allowance of pipe corrosion protection equipment. To limit this over voltage, this study used proper lightning protection equipment characteristics. From the result of simulation and the proper characteristics of lightning protection equipment, the transient voltage was limited follow BS 60950 standard. The result showed that the correct lightning protection equipment will help to reduce damage to asset of petroleum transportation industry from lightning strike. (C) 2013 The Authors. Published by Elsevier B.V.
引用
收藏
页码:148 / 158
页数:11
相关论文
共 9 条
[1]  
[Anonymous], 2011, EM BINT HUS SIM STUD
[2]  
Klairuang Nattaya, 2005, EFFECT ELECTR FIELDS
[3]  
Klairuang Nattaya, LIGHTNING PERFORMANC
[4]   Induced voltages on long aerial and buried pipelines due to transmission line transients [J].
Kopsidas, Konstantinos ;
Cotton, Ian .
IEEE TRANSACTIONS ON POWER DELIVERY, 2008, 23 (03) :1535-1543
[5]  
Peabody A.W., 2001, CONTROL PIPELINE COR, P30
[6]  
Takato Kenji, 2011, INT J SYSTEMS APPL E, V5
[7]  
Thai Petroleum Pipeline Co. LTD.Department of Electrical Engineering, 11028267 THAI PETR P
[8]  
Topradith Boonlerd, 2012, 4 EL ENG NETW 2012 N, P184
[9]  
Xiao Kun, 2002, P 4 WORLD C INT CONT