Monte Carlo simulation of optical clearing of paper in optical coherence tomography

被引:18
|
作者
Kirillin, MY
Priezzhev, A
Hast, J
Myllylä, R
机构
[1] MV Lomonosov Moscow State Univ, Dept Phys, Moscow 119992, Russia
[2] Univ Oulu, Fac Technol, Optoelect & Measurement Tech Lab, Oulu 90014, Finland
[3] MV Lomonosov Moscow State Univ, Moscow Russia Int Laser Ctr, Moscow 119992, Russia
关键词
optical coherence tomography; coherence length; light scattering; Monte Carlo simulation; optical clearing of paper; contactless measurements;
D O I
10.1070/QE2006v036n02ABEH013120
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Signals of an optical coherence tomograph from paper samples are calculated by the Monte Carlo method before and after the action of different immersion liquids such as ethanol, glycerol, benzyl alcohol, and I-pentanol. It is shown within the framework of the model used that all these liquids reduce the contrast of the inhomogeneity image in upper layers of the samples, considerably improving, however, the visibility of lower layers, allowing the localisation of the rear boundary of a medium being probed, which is important for precision contactless measuring a paper sheet thickness, for example, during the manufacturing process. The results of calculations are in well agreement with experimental data.
引用
收藏
页码:174 / 180
页数:7
相关论文
共 50 条
  • [1] Optical coherence tomography of paper:: Monte Carlo simulation for multilayer model
    Kirillin, M. Yu.
    Myllyla, R.
    Priezzhev, A. V.
    SARATOV FALL MEETING 2006: COHERENT OPTICS OF ORDERED AND RANDOM MEDIA VII, 2007, 6536
  • [2] Simulation of optical coherence tomography using Monte Carlo method
    Jia Ya-Qing
    Liang Yan-Mei
    Zhu Xiao-Nong
    ACTA PHYSICA SINICA, 2007, 56 (07) : 3861 - 3866
  • [3] Monte Carlo simulation of optical coherence tomography for turbid media with arbitrary spatial distributions
    Malektaji, Siavash
    Lima, Ivan T., Jr.
    Sherif, Sherif S.
    JOURNAL OF BIOMEDICAL OPTICS, 2014, 19 (04)
  • [4] Accurate Monte Carlo simulation of frequency-domain optical coherence tomography
    Wang, Yan
    Bai, Li
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2019, 35 (04)
  • [5] Monte Carlo method for simulating optical coherence tomography signal in homogeneous turbid media
    Zhang, Fengsheng
    Kinnunen, Matti
    Popov, Alexey
    Myllyla, Risto
    ADVANCED LASER TECHNOLOGIES 2007, 2008, 7022
  • [6] Study on effective probe depth of optical coherence tomography system by Monte Carlo simulation
    Ye, Qing
    Zhou, Wenyuan
    Wang, Jin
    Zhang, Chunping
    Tian, Jianguo
    OPTIK, 2013, 124 (21): : 4909 - 4911
  • [7] Monte Carlo Investigation of Optical Coherence Tomography Retinal Oximetry
    Chen, Siyu
    Yi, Ji
    Liu, Wenzhong
    Backman, Vadim
    Zhang, Hao F.
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2015, 62 (09) : 2308 - 2315
  • [8] Monte Carlo simulations of arterial imaging with optical coherence tomography
    Amendt, P
    Estabrook, K
    Everett, M
    London, RA
    Maitland, D
    Zimmerman, G
    Colston, B
    Da Silva, L
    Sathyam, U
    COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICAL SCIENCE AND CLINICAL APPLICATIONS IV, 2000, 3915 : 202 - 213
  • [9] Glucose sensing in aqueous Intralipid™ suspension with an optical coherence tomography system:: experiment and Monte Carlo simulation
    Kirillin, M
    Priezzhev, AV
    Kinnunen, M
    Alarousu, E
    Zhao, Z
    Hast, J
    Myllylä, R
    OPTICAL DIAGNOSTICS AND SENSING IV, 2004, 5325 : 164 - 173
  • [10] Blood optical clearing studied by optical coherence tomography
    Zhernovaya, Olga
    Tuchin, Valery V.
    Leahy, Martin J.