Remote control of implanted devices through Home Monitoring™ technology improves detection and clinical management of atrial fibrillation

被引:114
作者
Ricci, Renato Pietro [1 ]
Morichelli, Loredana [1 ]
Santini, Massimo [1 ]
机构
[1] San Filippo Neri Hosp, Dept Cardiol, I-00135 Rome, Italy
来源
EUROPACE | 2009年 / 11卷 / 01期
关键词
CARDIOVERTER-DEFIBRILLATORS; PACEMAKER; BRADYCARDIA; STROKE; CARE; MORTALITY; WIRELESS; IMPACT; RISK;
D O I
10.1093/europace/eun303
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To evaluate the impact of Home Monitoring (TM) (HM) technology on detection and treatment of atrial fibrillation (AF). One hundred and sixty-six patients (mean age 73 +/- 10 years, 112 males) received HM devices [121 pacemakers, 22 implantable cardioverter defibrillators (ICDs), and 23 ICDs combined with cardiac resynchronization therapy]. A nurse consulted the cardioreports on the website and submitted the alerts for AF (new onset AF, persistent AF, and AF burden of > 10% for > 5 consecutive days) to the physician. During a mean follow-up of 488 +/- 203 days, 42 patients (26%) had alerts for AF. Twenty-two patients had no history of AF before implant. In nine patients, no further action was taken. For the remaining 33 patients, an unscheduled follow-up was performed: in 16, antiarrhythmic drug therapy was introduced/modified; in 15, anticoagulation was started; in 2, antiplatelet drugs were introduced; in 7, an external cardioversion was performed; in 2 patients, the device was reprogrammed to avoid intermittent atrial undersensing during AF; and in 4 patients, no further action was taken. In four cases the arrhythmia was not confirmed (false positive). The median time to the first intervention for AF was 50 days (148 days before the scheduled follow-up). The HM technology allowed early detection of AF in paced patients and early reaction to optimize medical treatment.
引用
收藏
页码:54 / 61
页数:8
相关论文
共 25 条
[1]   What evidence do we have to replace in-hospital implantable cardioverter clefibrillator follow-up? [J].
Brugada, P .
CLINICAL RESEARCH IN CARDIOLOGY, 2006, 95 (Suppl 3) :3-9
[2]   Evaluation of electromagnetic interference of GSM mobile phones with pacemakers featuring remote monitoring functions [J].
Calcagnini, G ;
Censi, F ;
Floris, M ;
Pignalberi, C ;
Ricci, R ;
Biancalana, G ;
Bartolini, P ;
Santini, M .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2006, 29 (04) :380-385
[3]   Monitored atrial fibrillation duration predicts arterial embolic events in patients suffering from bradycardia and atrial fibrillation implanted with antitachycardia pacemakers [J].
Capucci, A ;
Santini, M ;
Padeletti, L ;
Gulizia, M ;
Botto, G ;
Boriani, G ;
Ricci, R ;
Favale, S ;
Zolezzi, F ;
Di Belardino, N ;
Molon, G ;
Drago, F ;
Villani, GQ ;
Mazzini, E ;
Vimercati, M ;
Grammatico, A .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 46 (10) :1913-1920
[4]   Prevalence of supraventricular arrhythmias from the automated analysis of data stored in the DDD pacemakers of 617 patients: The AIDA study [J].
Defaye, P ;
Dournaux, F ;
Mouton, E .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1998, 21 (01) :250-255
[5]   Predicting mortality and rehospitalization in heart failure patients with Home Monitoring - The home CARE pilot study [J].
Ellery, S ;
Pakrashi, T ;
Paul, V ;
Sack, S .
CLINICAL RESEARCH IN CARDIOLOGY, 2006, 95 (Suppl 3) :29-35
[6]   Potential cost savings by telemedicine-assisted long-term care of implantable cardioverter defibrillator recipients [J].
Fauchier, L ;
Sadoul, N ;
Kouakam, C ;
Briand, F ;
Chauvin, M ;
Babuty, D ;
Clementy, J .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2005, 28 :S255-S259
[7]   Management of atrial tachyarrhythmias:: Benefits of pacemaker diagnostics [J].
Fauchier, L ;
Briand, F ;
Soto, FX ;
Quennelle, F ;
Lévy, J ;
Darmon, JP ;
Lellouche, D ;
Lavergne, T ;
Poret, P ;
Pelade, C ;
Babuty, D .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2003, 26 (01) :233-238
[8]   ACC/AHA/ESC 2006 guidelines for the management of patients with atrial fibrillation:: full text [J].
Fuster, Valentin ;
Ryden, Lars E. ;
Cannom, David S. ;
Crijns, Harry J. ;
Curtis, Anne B. ;
Ellenbogen, Kenneth A. ;
Halperin, Jonathan L. ;
Le Heuzey, Jean-Yves ;
Kay, G. Neal ;
Lowe, James E. ;
Olsson, S. Bertil ;
Prystowsky, Eric N. ;
Tamargo, Juan Luis ;
Wann, Samuel .
EUROPACE, 2006, 8 (09) :651-745
[9]   Atrial high rate episodes detected by pacemaker diagnostics predict death and stroke - Report of the atrial diagnostics ancillary study of the MOde Selection Trial (MOST) [J].
Glotzer, TV ;
Hellkamp, AS ;
Zimmerman, J ;
Sweeney, MO ;
Yee, R ;
Marinchak, R ;
Cook, J ;
Paraschos, A ;
Love, J ;
Radoslovich, G ;
Lee, KL ;
Lamas, GA .
CIRCULATION, 2003, 107 (12) :1614-1619
[10]   Long-term risk of recurrent atrial fibrillation as documented by an Implantable monitoring device -: Implications for optimal patient care [J].
Israel, CW ;
Grönefeld, G ;
Ehrlich, JR ;
Li, YG ;
Hohnloser, SH .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (01) :47-52