Sensitivity comparison of inertial to optical motion capture during gait: implications for tracking recovery

被引:0
|
作者
Lee, Jeonghwan [1 ]
Shin, Sung Yul [1 ]
Ghorpade, Gaurav [1 ]
Akbas, Tunc [1 ]
Sulzer, James [1 ]
机构
[1] Univ Texas Austin, Dept Mech Engn, Austin, TX 78712 USA
关键词
WALKING; TREADMILL; SYSTEM;
D O I
10.1109/icorr.2019.8779411
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Wearable sensors provide a foundation for development of wearable robotic technology to be used in clinical applications. Inertial motion capture (IMC) has emerged as a viable alternative to more cumbersome, non-portable optical methods. Previous work has validated the accuracy of IMC for gait compared to optical motion capture (OMC). however, it is unclear how well IMC can measure the small changes in gait function needed to gauge recovery. In this study, we evaluate the sensitivity of IMC compared to OMC to small changes in gait on a cohort of unimpaired individuals during treadmill walking. Eight individuals walked on a split-belt treadmill in three-minute trials with five randomized conditions: right belt speed decrementing at 0.05 m/s from 1.0 m/s, all with left belt held at 1.0 m/s, simulating recovery of hemiparetic gait. We extracted the root mean square deviation (RMSD) of joint kinematics between limbs and within the limb with modulated gait speed as the main outcome measure. We used linear mixed models to identify differences in sensitivity to changes in gait asymmetry and gait speed. Based on these models, we estimated the minimal detectible interval in gait parameters. We found that IMC was capable of measuring a difference in gait speed of 0.08 m/s, roughly the equivalent of two weeks recovery progress. Statistically we could not conclude a difference of sensitivity between INIC and OMC, although there is a strong trend that IMC is more sensitive to changes in gait. We conclude that IMC is a valid tool to measure progress in gait kinematics over the course of recovery.
引用
收藏
页码:139 / 144
页数:6
相关论文
共 50 条
  • [41] Evaluation of an Open Access Markerless Motion Capture System During Gait Analysis
    Zavala, Alejandro
    Bejarano Mendoza, Paula A.
    Castillo Martinez, Juan A.
    Clementi, Luis A.
    Braidot, Ariel A. A.
    ADVANCES IN BIOENGINEERING AND CLINICAL ENGINEERING, VOL 1, SABI 2023, 2024, 106 : 413 - 427
  • [42] Quantification of equine sacral and iliac motion during gait: A comparison between motion capture with skin-mounted and bone-fixated sensors
    Goff, L.
    van Weeren, P. R.
    Jeffcott, L.
    Condie, P.
    McGowan, C.
    EQUINE VETERINARY JOURNAL, 2010, 42 : 468 - 474
  • [43] Synchronizing eye tracking and optical motion capture: How to bring them together
    Burger, Birgitta
    Puupponen, Anna
    Jantunen, Tommi
    JOURNAL OF EYE MOVEMENT RESEARCH, 2018, 11 (02): : 1 - 16
  • [44] Online Marker Labeling for Fully Automatic Skeleton Tracking in Optical Motion Capture
    Meyer, Johannes
    Kuderer, Markus
    Mueller, Joerg
    Burgard, Wolfram
    2014 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION (ICRA), 2014, : 5652 - 5657
  • [45] Using skeleton-based tracking to increase the reliability of optical motion capture
    Herda, L
    Fua, P
    Plänkers, R
    Boulic, R
    Thalmann, D
    HUMAN MOVEMENT SCIENCE, 2001, 20 (03) : 313 - 341
  • [46] Estimation of Spinal Loading During Manual Materials Handling Using Inertial Motion Capture
    Larsen, Frederik Greve
    Svenningsen, Frederik Petri
    Andersen, Michael Skipper
    De Zee, Mark
    Skals, Sebastian
    ANNALS OF BIOMEDICAL ENGINEERING, 2020, 48 (02) : 805 - 821
  • [47] Estimation of Spinal Loading During Manual Materials Handling Using Inertial Motion Capture
    Frederik Greve Larsen
    Frederik Petri Svenningsen
    Michael Skipper Andersen
    Mark de Zee
    Sebastian Skals
    Annals of Biomedical Engineering, 2020, 48 : 805 - 821
  • [48] Fastest Gait Parameters Estimation Precision Comparison Utilizing High-Sensitivity and Low-Sensitivity Inertial Sensor
    Azman, Amir Mukhriz
    Kuga, Hirofumi
    Sagawa, Koichi
    Nagai, Chikara
    2ND INTERNATIONAL CONFERENCE FOR INNOVATION IN BIOMEDICAL ENGINEERING AND LIFE SCIENCES, 2018, 67 : 79 - 84
  • [49] Comparison of Markerless and Marker-Based Motion Capture Technologies through Simultaneous Data Collection during Gait: Proof of Concept
    Ceseracciu, Elena
    Sawacha, Zimi
    Cobelli, Claudio
    PLOS ONE, 2014, 9 (03):
  • [50] Comparison of kinematics and joint moments calculations for lower limbs during gait using markerless and marker-based motion capture
    Huang, Tianchen
    Ruan, Mianfang
    Huang, Shangjun
    Fan, Linlin
    Wu, Xie
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2024, 12