OPTIMAL WINDOW GEOMETRY FACTORS FOR ELEMENTARY SCHOOL BUILDINGS IN PORTUGAL

被引:5
作者
Carlos, Jorge S. [1 ]
机构
[1] Univ Beira Interior, Ctr Mat & Bldg Technol CMADE UBI, Rua Marques DAvila & Bolama, P-6200001 Covilha, Portugal
来源
JOURNAL OF GREEN BUILDING | 2018年 / 13卷 / 01期
关键词
school building; classroom; windows; solar heat gain; daylight; PERFORMANCE;
D O I
10.3992/1943-4618.13.1.185
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
With respect to thermal performance, windows are the weakest component of the building envelope, essentially because the U-value is usually higher than the opaque envelope. This would allow the highest heat conductance of the building envelope. However, it also helps buildings to gain useful solar heat during winter. Therefore, it has been generally accepted that passive buildings would have small windows towards the poles and large windows facing the equator (Persson, Roos, and Wall 2006). In spite of this guideline, large or fully glazed facades have been used in modern architecture. The intensive use of air conditioning is the result of overheating and high thermal loss problems, which otherwise would lead to thermal discomfort. This extensive use of large windows associated with high energy consumption has motivated researchers to study this building component. Window areas were investigated by Persson et al. (Persson, Roos, and Wall 2006) on 20 terraced houses with larger windows facing the equator and built in Gothenburg. The building envelope was well insulated and fitted with energy efficient windows. It was found that energy efficient windows do not have a major influence on the heating demand in the winter, but it is relevant for the cooling need in summer. Therefore, reduced indoor illuminance due to small windows can be solved by enlarging them in order to obtain relevant daylighting conditions. When efficient windows are designed for a warm climate, as in Mexico, reducing heat flux and solar transmittance indoors was the best option for energy savings (Aguilar et al. 2017). However, reducing solar transmittance influences the indoor illuminance, which was not analyzed.
引用
收藏
页码:185 / 197
页数:13
相关论文
共 18 条
  • [1] Thermal performance of a room with a double glazing window using glazing available in Mexican market
    Aguilar, J. O.
    Xaman, J.
    Olazo-Gomez, Y.
    Hernandez-Lopez, I.
    Becerra, G.
    Jaramillo, O. A.
    [J]. APPLIED THERMAL ENGINEERING, 2017, 119 : 505 - 515
  • [2] Amaral Ana Rita, 2015, ENERGY SUSTAINABILIT, P7
  • [3] [Anonymous], 2002, COM EUR NORM 1
  • [4] [Anonymous], BREEAM NEW CONSTR NO
  • [5] Sustainability assessment of government school buildings in Portugal
    Carlos, Jorge S.
    [J]. ARCHITECTURAL SCIENCE REVIEW, 2016, 59 (05) : 413 - 422
  • [6] RETROFIT MEASURES IN OLD ELEMENTARY SCHOOL BUILDINGS TOWARDS ENERGY EFFICIENCY
    Carlos, Jorge S.
    Corvacho, Helena
    [J]. JOURNAL OF CIVIL ENGINEERING AND MANAGEMENT, 2010, 16 (04) : 567 - 576
  • [7] EnergyPlus: creating a new-generation building energy simulation program
    Crawley, DB
    Lawrie, LK
    Winkelmann, FC
    Buhl, WF
    Huang, YJ
    Pedersen, CO
    Strand, RK
    Liesen, RJ
    Fisher, DE
    Witte, MJ
    Glazer, J
    [J]. ENERGY AND BUILDINGS, 2001, 33 (04) : 319 - 331
  • [8] Analysis and modelling of window and glazing systems energy performance for a well insulated residential building
    Gasparella, Andrea
    Pernigotto, Giovanni
    Cappelletti, Francesca
    Romagnoni, Piercarlo
    Baggio, Paolo
    [J]. ENERGY AND BUILDINGS, 2011, 43 (04) : 1030 - 1037
  • [9] An Ideal Window Area concept for energy efficient integration of daylight and artificial light in buildings
    Ghisi, E
    Tinker, JA
    [J]. BUILDING AND ENVIRONMENT, 2005, 40 (01) : 51 - 61
  • [10] Windows in the buildings of tomorrow: Energy losers or energy gainers?
    Grynning, Steinar
    Gustavsen, Arild
    Time, Berit
    Jelle, Bjorn Petter
    [J]. ENERGY AND BUILDINGS, 2013, 61 : 185 - 192