DEVELOPMENT AND CHARACTERIZATION OF A SENSOR BASED ON CARBON NANOFIBERS: APPLICATION TO ACETAZOLAMIDE DETERMINATION IN PHARMACEUTICALS AND BIOLOGICAL FLUIDS

被引:2
|
作者
Mundaca-Uribe, Rodolfo [1 ]
De Diego, Marta [1 ]
Henriquez-Aedo, Karem [2 ]
Aranda, Mario [2 ]
Pena-Farfal, Carlos [3 ]
机构
[1] Univ Concepcion, Fac Farm, Dept Farm, Concepcion 4070043, Chile
[2] Univ Concepcion, Dept Ciencia & Tecnol Alimentos, Fac Farm, Concepcion 4070043, Chile
[3] Univ Concepcion, Fac Ciencias Quim, Dept Quim Analit, Concepcion 4070371, Chile
来源
关键词
ELECTROCHEMICAL SENSOR; SENSITIVE DETERMINATION; HUMAN URINE; HUMAN SERUM; NANOTUBES; ELECTRODE; SURFACE;
D O I
10.4067/s0717-97072019000104382
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Acetazolamide (ACZ) is a carbonic anhydrase inhibitor that exhibits diuretic activity. In medicine, it is principally used in open-angle glaucoma. for prevention or amelioration of symptoms associated with acute high-altitude sickness and as an adjunct to other anticonvulsants in centrencephalic epilepsies. Furthermore, ACZ is sometimes used by athletes to mask the presence of doping substances, so its use has been banned in competitions. The aim of this work was the development of a sensor to determine ACZ, in pharmaceuticals. as quality control way, and serum, for clinical and doping analyzes. The sensor has been developed modifying a glassy carbon electrode with carbon nanofibers. The electrochemical characterization of the sensor was performed by cyclic voltammetry using the redox mediator potassium ferrocyanide. ACZ electiuchemical behavior was studied as well. Measurements were performed in a conventional three electrodes cell using differential pulse voltammetry. The influence of some experimental variables involved in the preparation and performance of the sensor -amount of modifier, supporting electrolyte, pH, scan rate and pulse amplitude- were optimized. This methodology provided a linear calibration plot for ACZ in the 1 - 17 AM concentration range. Furthermore, the proposed sensor exhibited suitable analytical properties, with detection and quantification limits of 0.06 mu M and 0.2 mu M respectively; analytical sensitivity of 1.142 mu A mu M, repeatability of 0.72 %, and it was applied to determine ACZ, in pharmaceuticals (tablets) and spiked human serum, being an excellent tool to perform quality control and antidoping control.
引用
收藏
页码:4382 / 4385
页数:4
相关论文
共 50 条
  • [41] Highly sensitive spectrofluorimetric method for rapid determination of orciprenaline in biological fluids and pharmaceuticals
    Ibrahim, F. A.
    Fathy, M. E.
    Elmansi, H. M.
    LUMINESCENCE, 2019, 34 (01) : 77 - 83
  • [42] Rapid determination of levofloxacin in pharmaceuticals and biological fluids using a new chemiluminescence system
    Xiaodong Shao
    Ying Li
    Yangqin Liu
    Zhenghua Song
    Journal of Analytical Chemistry, 2011, 66 : 102 - 107
  • [43] Polarographic Determination of Lisinopril in Pharmaceuticals and Biological Fluids Through Treatment with Nitrous Acid
    Nahed El-Enany
    Fathalla Belal
    Sheikha Al-Ghannam
    Microchimica Acta, 2003, 141 : 55 - 61
  • [44] Eu(III)-Sensitized Luminescence Probe for Determination of Tolnaftate in Pharmaceuticals and Biological Fluids
    Alarfaj, Nawal A.
    El-Tohamy, Maha F.
    JOURNAL OF AOAC INTERNATIONAL, 2016, 99 (02) : 380 - 385
  • [45] Rapid Determination of Levofloxacin in Pharmaceuticals and Biological Fluids Using a New Chemiluminescence System
    Shao, Xiaodong
    Li, Ying
    Liu, Yangqin
    Song, Zhenghua
    JOURNAL OF ANALYTICAL CHEMISTRY, 2011, 66 (01) : 102 - 107
  • [46] Polarographic determination of lisinopril in pharmaceuticals and biological fluids through treatment with nitrous acid
    El-Enany, N
    Belal, F
    Al-Ghannam, S
    MICROCHIMICA ACTA, 2003, 141 (1-2) : 55 - 61
  • [47] Validated Potentiometric Sensors for Determination of Ramipril in Pharmaceuticals and Biological Fluids using in situ Screen Printed and Carbon Paste Electrodes
    Marwa E. Eman Yossri Frag
    Mohamed O. Mohamed
    Journal of Analytical Chemistry, 2020, 75 : 384 - 395
  • [48] Validated Potentiometric Sensors for Determination of Ramipril in Pharmaceuticals and Biological Fluids using in situ Screen Printed and Carbon Paste Electrodes
    Frag, Eman Yossri
    Mohamed, Marwa E.
    Elhassan, Mohamed O.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2020, 75 (03) : 384 - 395
  • [49] A Sensor for Determination of Tramadol in Pharmaceutical Preparations and Biological Fluids Based on Multi-Walled Carbon Nanotubes-Modified Glassy Carbon Electrode
    Afrasiabi, Mohammad
    Zad, Zeinab Rezayati
    Kianipour, Shokat
    Babaei, Ali
    Taheri, Ali Reza
    JOURNAL OF THE CHEMICAL SOCIETY OF PAKISTAN, 2013, 35 (04): : 1106 - 1112
  • [50] Molecularly imprinted polymer based potentiometric sensor for the determination of hydroxyzine in tablets and biological fluids
    Javanbakht, Mehran
    Fard, Solmaz Eynollahi
    Mohammadi, Ali
    Abdouss, Majid
    Ganjali, Mohammad Reza
    Norouzi, Parviz
    Safaraliee, Leila
    ANALYTICA CHIMICA ACTA, 2008, 612 (01) : 65 - 74