DEVELOPMENT AND CHARACTERIZATION OF A SENSOR BASED ON CARBON NANOFIBERS: APPLICATION TO ACETAZOLAMIDE DETERMINATION IN PHARMACEUTICALS AND BIOLOGICAL FLUIDS

被引:2
|
作者
Mundaca-Uribe, Rodolfo [1 ]
De Diego, Marta [1 ]
Henriquez-Aedo, Karem [2 ]
Aranda, Mario [2 ]
Pena-Farfal, Carlos [3 ]
机构
[1] Univ Concepcion, Fac Farm, Dept Farm, Concepcion 4070043, Chile
[2] Univ Concepcion, Dept Ciencia & Tecnol Alimentos, Fac Farm, Concepcion 4070043, Chile
[3] Univ Concepcion, Fac Ciencias Quim, Dept Quim Analit, Concepcion 4070371, Chile
来源
关键词
ELECTROCHEMICAL SENSOR; SENSITIVE DETERMINATION; HUMAN URINE; HUMAN SERUM; NANOTUBES; ELECTRODE; SURFACE;
D O I
10.4067/s0717-97072019000104382
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Acetazolamide (ACZ) is a carbonic anhydrase inhibitor that exhibits diuretic activity. In medicine, it is principally used in open-angle glaucoma. for prevention or amelioration of symptoms associated with acute high-altitude sickness and as an adjunct to other anticonvulsants in centrencephalic epilepsies. Furthermore, ACZ is sometimes used by athletes to mask the presence of doping substances, so its use has been banned in competitions. The aim of this work was the development of a sensor to determine ACZ, in pharmaceuticals. as quality control way, and serum, for clinical and doping analyzes. The sensor has been developed modifying a glassy carbon electrode with carbon nanofibers. The electrochemical characterization of the sensor was performed by cyclic voltammetry using the redox mediator potassium ferrocyanide. ACZ electiuchemical behavior was studied as well. Measurements were performed in a conventional three electrodes cell using differential pulse voltammetry. The influence of some experimental variables involved in the preparation and performance of the sensor -amount of modifier, supporting electrolyte, pH, scan rate and pulse amplitude- were optimized. This methodology provided a linear calibration plot for ACZ in the 1 - 17 AM concentration range. Furthermore, the proposed sensor exhibited suitable analytical properties, with detection and quantification limits of 0.06 mu M and 0.2 mu M respectively; analytical sensitivity of 1.142 mu A mu M, repeatability of 0.72 %, and it was applied to determine ACZ, in pharmaceuticals (tablets) and spiked human serum, being an excellent tool to perform quality control and antidoping control.
引用
收藏
页码:4382 / 4385
页数:4
相关论文
共 50 条
  • [31] Graphene modified Palladium sensor for electrochemical analysis of norepinephrine in pharmaceuticals and biological fluids
    Rosy
    Yadav, Saurabh K.
    Agrawal, Bharati
    Oyama, Munetaka
    Goyal, Rajendra N.
    ELECTROCHIMICA ACTA, 2014, 125 : 622 - 629
  • [32] Voltammetric and DFT studies on viloxazine: Analytical application to pharmaceuticals and biological fluids
    Garrido, E. Manuela P. J.
    Garrido, Jorge M. P. J.
    Esteves, Mario
    Santos-Silva, Alice
    Marques, M. Paula M.
    Borges, Ternanda
    ELECTROANALYSIS, 2008, 20 (13) : 1454 - 1462
  • [33] LC with Electrochemical Detection. Recent Application to Pharmaceuticals and Biological Fluids
    S. A. Özkan
    Chromatographia, 2007, 66 : 3 - 13
  • [34] LC with electrochemical detection. recent application to pharmaceuticals and biological fluids
    Oezkan, S. A.
    CHROMATOGRAPHIA, 2007, 66 (Suppl 1) : S3 - S13
  • [35] Augmented spectrofluorimetric determination of certain fluoroquinolones via micellar - Metal complex connection: Application to pharmaceuticals and biological fluids
    Derayea, Sayed Mohamed
    Omar, Mahmoud Ahmed
    Hammad, Mohamed Abdelkhalek
    Hassan, Yasser Farag
    El-Din, Khalid M. Badr
    MICROCHEMICAL JOURNAL, 2021, 160
  • [36] DETERMINATION OF ACETAZOLAMIDE IN BIOLOGICAL-FLUIDS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    GAL, J
    ELLIS, PP
    RENDI, M
    CURRENT EYE RESEARCH, 1981, 1 (06) : 361 - 365
  • [37] Development and characterization of composite carbon nanofibers surface-coated with ZnO/Ag nanoparticle arrays for ammonia sensor application
    Kharaghani, Davood
    Suzuki, Yuji
    Gitigard, Parastoo
    Ullah, Sana
    Kim, Ick Soo
    MATERIALS TODAY COMMUNICATIONS, 2020, 24 (24)
  • [38] Fluorimetric determination of prenalterol hydrochloride in pharmaceuticals and biological fluids based on its oxidation reaction by hexacyanoferrate(III)
    Aly, FA
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1999, 21 (03) : 483 - 489
  • [39] New potentiometric sensors based on selective recognition sites for determination of ephedrine in some pharmaceuticals and biological fluids
    Hassan, Saad S. M.
    Kamel, Ayman H.
    Abd El-Naby, Heba
    TALANTA, 2013, 103 : 330 - 336
  • [40] Development and validation of an HPLC method for the determination of six 1,4-benzodiazepines in pharmaceuticals and human biological fluids
    Uddin, Mohammad Nasir
    Samanidou, Victoria F.
    Papadoyannis, Ioannis N.
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2008, 31 (09) : 1258 - 1282