DEVELOPMENT AND CHARACTERIZATION OF A SENSOR BASED ON CARBON NANOFIBERS: APPLICATION TO ACETAZOLAMIDE DETERMINATION IN PHARMACEUTICALS AND BIOLOGICAL FLUIDS

被引:2
|
作者
Mundaca-Uribe, Rodolfo [1 ]
De Diego, Marta [1 ]
Henriquez-Aedo, Karem [2 ]
Aranda, Mario [2 ]
Pena-Farfal, Carlos [3 ]
机构
[1] Univ Concepcion, Fac Farm, Dept Farm, Concepcion 4070043, Chile
[2] Univ Concepcion, Dept Ciencia & Tecnol Alimentos, Fac Farm, Concepcion 4070043, Chile
[3] Univ Concepcion, Fac Ciencias Quim, Dept Quim Analit, Concepcion 4070371, Chile
来源
关键词
ELECTROCHEMICAL SENSOR; SENSITIVE DETERMINATION; HUMAN URINE; HUMAN SERUM; NANOTUBES; ELECTRODE; SURFACE;
D O I
10.4067/s0717-97072019000104382
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Acetazolamide (ACZ) is a carbonic anhydrase inhibitor that exhibits diuretic activity. In medicine, it is principally used in open-angle glaucoma. for prevention or amelioration of symptoms associated with acute high-altitude sickness and as an adjunct to other anticonvulsants in centrencephalic epilepsies. Furthermore, ACZ is sometimes used by athletes to mask the presence of doping substances, so its use has been banned in competitions. The aim of this work was the development of a sensor to determine ACZ, in pharmaceuticals. as quality control way, and serum, for clinical and doping analyzes. The sensor has been developed modifying a glassy carbon electrode with carbon nanofibers. The electrochemical characterization of the sensor was performed by cyclic voltammetry using the redox mediator potassium ferrocyanide. ACZ electiuchemical behavior was studied as well. Measurements were performed in a conventional three electrodes cell using differential pulse voltammetry. The influence of some experimental variables involved in the preparation and performance of the sensor -amount of modifier, supporting electrolyte, pH, scan rate and pulse amplitude- were optimized. This methodology provided a linear calibration plot for ACZ in the 1 - 17 AM concentration range. Furthermore, the proposed sensor exhibited suitable analytical properties, with detection and quantification limits of 0.06 mu M and 0.2 mu M respectively; analytical sensitivity of 1.142 mu A mu M, repeatability of 0.72 %, and it was applied to determine ACZ, in pharmaceuticals (tablets) and spiked human serum, being an excellent tool to perform quality control and antidoping control.
引用
收藏
页码:4382 / 4385
页数:4
相关论文
共 50 条
  • [21] Determination of Ascorbic Acid in Pharmaceuticals and Biological Fluids by the Quenching of Europium Luminescence
    Llorent-Martinez, E. J.
    Soler-Gallardo, M., I
    Fernandez-Poyatos, M. P.
    Ruiz-Medina, A.
    ANALYTICAL LETTERS, 2020, 53 (05) : 683 - 692
  • [22] Analytical methods for determination of glutathione and glutathione disulfide in pharmaceuticals and biological fluids
    Hamad, Amal
    Elshahawy, Mohamed
    Negm, Amr
    Mansour, Fotouh R.
    REVIEWS IN ANALYTICAL CHEMISTRY, 2019, 38 (04)
  • [23] Differential pulse voltammetric determination of methylprednilsolone in pharmaceuticals and human biological fluids
    Goyal, Rajendra N.
    Bachheti, Neeta
    Tyagi, Anuradha
    Pandey, Ashish K.
    ANALYTICA CHIMICA ACTA, 2007, 605 (01) : 34 - 40
  • [24] Differential pulse polarographic determination of moxifloxacin hydrochloride in pharmaceuticals and biological fluids
    Inam, Recai
    Mercan, Hulya
    Yilmaz, Emine
    Uslu, Bengi
    ANALYTICAL LETTERS, 2007, 40 (03) : 529 - 546
  • [25] Characterization of Carbon Nanofibers (CNFs) for Glucose based Biosensor Application
    Huq, Hasina F.
    Pinon, E. M.
    Braden, M.
    Acuna, J.
    2013 IEEE 56TH INTERNATIONAL MIDWEST SYMPOSIUM ON CIRCUITS AND SYSTEMS (MWSCAS), 2013, : 344 - 347
  • [26] A novel electrochemical sensor based on electrospun TiO2 nanoparticles/carbon nanofibers for determination of Idarubicin in biological samples
    Arkan, Elham
    Paimard, Giti
    Moradi, Khalil
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2017, 801 : 480 - 487
  • [27] New Electrochemical Sensor Based on Electrospun Carbon Nanofibers Modified with Cobalt Nanoparticles and Its Application for Atorvastatin Determination
    Gorska, Anna
    Zambrzycki, Marcel
    Paczosa-Bator, Beata
    Piech, Robert
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2022, 169 (09)
  • [28] New Electrochemical Sensor Based on Hierarchical Carbon Nanofibers with NiCo Nanoparticles and Its Application for Cetirizine Hydrochloride Determination
    Gorska, Anna
    Zambrzycki, Marcel
    Paczosa-Bator, Beata
    Piech, Robert
    MATERIALS, 2022, 15 (10)
  • [29] Multi-walled carbon nanotube/poly(glycine) modified carbon paste electrode for the determination of dopamine in biological fluids and pharmaceuticals
    Thomas, Tony
    Mascarenhas, Ronald J.
    Swamy, B. E. Kumara
    Martis, Praveen
    Mekhalif, Zineb
    Sherigara, B. S.
    COLLOIDS AND SURFACES B-BIOINTERFACES, 2013, 110 : 458 - 465
  • [30] Development of New Method for Simultaneous Analysis of Piracetam and Levetiracetam in Pharmaceuticals and Biological Fluids: Application in Stability Studies
    Siddiqui, Farhan Ahmed
    Sher, Nawab
    Shafi, Nighat
    Sial, Alisha Wafa
    Ahmad, Mansoor
    Mehjebeen
    Naseem, Huma
    BIOMED RESEARCH INTERNATIONAL, 2014, 2014