DEVELOPMENT AND CHARACTERIZATION OF A SENSOR BASED ON CARBON NANOFIBERS: APPLICATION TO ACETAZOLAMIDE DETERMINATION IN PHARMACEUTICALS AND BIOLOGICAL FLUIDS

被引:2
|
作者
Mundaca-Uribe, Rodolfo [1 ]
De Diego, Marta [1 ]
Henriquez-Aedo, Karem [2 ]
Aranda, Mario [2 ]
Pena-Farfal, Carlos [3 ]
机构
[1] Univ Concepcion, Fac Farm, Dept Farm, Concepcion 4070043, Chile
[2] Univ Concepcion, Dept Ciencia & Tecnol Alimentos, Fac Farm, Concepcion 4070043, Chile
[3] Univ Concepcion, Fac Ciencias Quim, Dept Quim Analit, Concepcion 4070371, Chile
来源
关键词
ELECTROCHEMICAL SENSOR; SENSITIVE DETERMINATION; HUMAN URINE; HUMAN SERUM; NANOTUBES; ELECTRODE; SURFACE;
D O I
10.4067/s0717-97072019000104382
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Acetazolamide (ACZ) is a carbonic anhydrase inhibitor that exhibits diuretic activity. In medicine, it is principally used in open-angle glaucoma. for prevention or amelioration of symptoms associated with acute high-altitude sickness and as an adjunct to other anticonvulsants in centrencephalic epilepsies. Furthermore, ACZ is sometimes used by athletes to mask the presence of doping substances, so its use has been banned in competitions. The aim of this work was the development of a sensor to determine ACZ, in pharmaceuticals. as quality control way, and serum, for clinical and doping analyzes. The sensor has been developed modifying a glassy carbon electrode with carbon nanofibers. The electrochemical characterization of the sensor was performed by cyclic voltammetry using the redox mediator potassium ferrocyanide. ACZ electiuchemical behavior was studied as well. Measurements were performed in a conventional three electrodes cell using differential pulse voltammetry. The influence of some experimental variables involved in the preparation and performance of the sensor -amount of modifier, supporting electrolyte, pH, scan rate and pulse amplitude- were optimized. This methodology provided a linear calibration plot for ACZ in the 1 - 17 AM concentration range. Furthermore, the proposed sensor exhibited suitable analytical properties, with detection and quantification limits of 0.06 mu M and 0.2 mu M respectively; analytical sensitivity of 1.142 mu A mu M, repeatability of 0.72 %, and it was applied to determine ACZ, in pharmaceuticals (tablets) and spiked human serum, being an excellent tool to perform quality control and antidoping control.
引用
收藏
页码:4382 / 4385
页数:4
相关论文
共 50 条
  • [11] An aptamerelectrochemical sensor based on functional carbon nanofibers for tetracycline determination
    Zhang, Li
    Yin, Ming
    Wei, Xiuxia
    Sun, Yiwei
    Luo, Yuting
    Lin, Huaqing
    Shu, Ruxin
    Xu, Dongpo
    BIOELECTROCHEMISTRY, 2024, 157
  • [12] AN APPLICATION OF MASS FRAGMENTOGRAPHY TO THE DETERMINATION OF ACETAZOLAMIDE IN BODY-FLUIDS
    KISHIDA, K
    MANABE, R
    BANDO, K
    MIWA, Y
    ANALYTICAL LETTERS PART B-CLINICAL AND BIOCHEMICAL ANALYSIS, 1981, 14 (05): : 335 - 347
  • [13] Differential pulse polarographic determination of ofloxacin in pharmaceuticals and biological fluids
    Rizk, M
    Belal, F
    Aly, FA
    El-Enany, NM
    TALANTA, 1998, 46 (01) : 83 - 89
  • [14] Anodic voltammetry of abacavir and its determination in pharmaceuticals and biological fluids
    Uslu, B
    Özkan, SA
    ELECTROCHIMICA ACTA, 2004, 49 (25) : 4321 - 4329
  • [15] Cyclodextrin enhanced spectrofluorimetric determination of fluoxetine in pharmaceuticals and biological fluids
    Berzas, JJ
    Alañón, A
    Lázaro, JA
    TALANTA, 2002, 58 (02) : 301 - 309
  • [16] Development of a validated HPLC method for the determination of four penicillin antibiotics in pharmaceuticals and human biological fluids
    Samanidou, Victoria F.
    Evaggelopoulou, Evaggelia N.
    Papadoyannis, Ioannis N.
    JOURNAL OF SEPARATION SCIENCE, 2006, 29 (11) : 1550 - 1560
  • [17] Construction and Validation of New Electrochemical Carbon Nanotubes Sensors for Determination of Acebutolol Hydrochloride in Pharmaceuticals and Biological Fluids
    Alarfaj, Nawal A.
    El-Tohamy, Maha F.
    JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2014, 61 (08) : 910 - 920
  • [18] Molecularly imprinted electrochemical sensor based on carbon nanofibers for Amiodarone determination
    Banan, Kamran
    Niknam, Sedigheh
    Ahmadi, Mahnaz
    Tabasi, Saeed
    Ghalkhani, Masoumeh
    Adabi, Mahdi
    Ghorbani-Bidkoreph, Fatemeh
    MICROCHEMICAL JOURNAL, 2024, 200
  • [19] Development and validation of stability indicating method for determination of sertraline following ICH guidlines and its determination in pharmaceuticals and biological fluids
    Walash, Mohamed I.
    Belal, Fathallah F.
    El-Enany, Nahed M.
    Elmansi, Heba
    CHEMISTRY CENTRAL JOURNAL, 2011, 5
  • [20] Development and validation of stability indicating method for determination of sertraline following ICH guidlines and its determination in pharmaceuticals and biological fluids
    Mohamed I Walash
    Fathallah F Belal
    Nahed M El-Enany
    Heba Elmansi
    Chemistry Central Journal, 5