The Influence of On-pump Versus Off-pump Surgery on Short- and Medium-term Postoperative Coronary Flow Reserve After Coronary Artery Bypass Grafting

被引:1
作者
Ozulku, Mehmet [1 ]
Caliskan, Mustafa [2 ]
Saba, Tonguc [1 ]
Aksu, Feyza [3 ]
Ciftci, Ozgur [2 ]
Gullu, Hakan [2 ]
Guven, Aytekin [2 ]
Kostek, Osman [3 ]
Caklili, Ozge Telci [3 ]
Aslamaci, Sait [1 ]
Muderrisoglu, Haldun [2 ]
机构
[1] Baskent Univ, Konya Teaching & Med Res Ctr, Dept Cardiovasc Surg, Konya, Turkey
[2] Baskent Univ, Konya Teaching & Med Res Ctr, Dept Cardiol, Hoca Cihan Mah,Saray Cad 1, Selcuklu, Konya, Turkey
[3] Istanbul Medeniyet Univ, Teaching & Med Res Ctr, Dept Internal Med & Cardiol, Istanbul, Turkey
关键词
Off-pump surgery; Coronary flow reserve; hsCRP; Diastolic function; BLOOD-FLOW; DOPPLER-ECHOCARDIOGRAPHY; VELOCITY; ULTRASOUND;
D O I
10.1016/j.hlc.2016.02.012
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Although several clinical trials have compared surgical outcomes between off-pump and on-pump coronary artery bypass grafting (CABG), whether there is a difference in the early- and medium-term postoperative coronary microvascular functions is not fully understood. We compared short- and medium-term coronary microvascular function after off-pump and on-pump CABG. Methods A prospective study of patients undergoing off-pump and on-pump CABG. Eighty-two patients scheduled for CABG were recruited: 38 underwent off-pump surgery and 44 on-pump surgery. Each participant's coronary flow reserve (CFR) and diastolic function were measured with transthoracic Doppler echocardiography six and 12 months after surgery. Results Baseline and hyperaemic diastolic peak flow velocity in the left anterior descending artery were similar in both groups, as was CFR (2.22 +/- 0.66) in the off-pump group compared with (2.13 +/- 0.61) in the on-pump group, (P = 0.54). Coronary flow reserve was significantly and inversely correlated with high sensitivity C-reactive protein concentration (r = -0.416; P < 0.001) and positively correlated with mitral E/ A-wave velocity ratio (r = 0.247; P = 0.02). Stepwise linear regression analysis revealed that only high sensitivity C-reactive protein concentration was independently correlated with CFR (beta = -0.272, P = 0.02). Conclusions Heart-lung bypass technique had no medium-term influence on the coronary microcirculation, despite a possible initial unfavourable effect. Serum hs-CRP concentration was an independent predictor of medium-term coronary microvascular dysfunction.
引用
收藏
页码:1232 / 1239
页数:8
相关论文
共 50 条
  • [31] The current status of multi-arterial off-pump coronary artery bypass grafting
    Tomoaki, Suzuki
    Tohru, Asai
    SURGERY TODAY, 2016, 46 (01) : 1 - 12
  • [32] Off-Pump Coronary Artery Bypass Grafting: Department of Veteran Affairs' Use and Outcomes
    Deo, Salil, V
    Elgudin, Yakov
    Shroyer, A. Laurie W.
    Altarabsheh, Salah
    Sharma, Vikas
    Rubelowsky, Joseph
    Cornwell, Lorraine
    Davierwala, Piroze
    Chu, Danny
    Cmolik, Brian
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2022, 11 (06):
  • [33] Revascularization by carotid artery stenting and off-pump coronary artery bypass
    Yang, Tao
    Zhang, Lefeng
    Wang, Xianqiang
    Dong, Hui
    Jiang, Xiongjing
    Sun, Hansong
    ANZ JOURNAL OF SURGERY, 2016, 86 (7-8) : 602 - 607
  • [34] Comparative effects of norepinephrine and vasopressin on internal thoracic arterial graft flow after off-pump coronary artery bypass grafting
    Park, Sung Yong
    Kim, Dae Hee
    Kim, Jin Soo
    Lim, Sang Hyun
    Hong, Yong Woo
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2011, 141 (01) : 151 - 154
  • [35] Revascularization in left main coronary artery disease: comparison of off-pump coronary artery bypass grafting vs percutaneous coronary intervention
    Jeong, Dong Seop
    Lee, Young Tak
    Chung, Su Ryeun
    Jeong, Jae Han
    Kim, Wook Sung
    Sung, Kiick
    Park, Pyo Won
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2013, 44 (04) : 718 - 724
  • [36] Is the evidence from first time off-pump coronary artery bypass graft surgery transferable to re-operative off-pump surgery?
    Sepehripour, Amir H.
    Suliman, Amna
    Stavridis, George
    Athanasiou, Thanos
    EXPERT REVIEW OF CARDIOVASCULAR THERAPY, 2014, 12 (11) : 1327 - 1335
  • [37] Myocardial Protection with Isoflurane During Off-Pump Coronary Artery Bypass Grafting: A Randomized Trial
    Tempe, Deepak K.
    Dutta, Devesh
    Garg, Mukesh
    Minhas, Harpreet
    Tomar, Akhlesh
    Virmani, Sanjula
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2011, 25 (01) : 59 - 65
  • [38] Off-Pump Coronary Artery Bypass Grafting with Mini-Sternotomy in the Treatment of Triple-Vessel Coronary Artery Disease
    Su, Pixiong
    Gu, Song
    Liu, Yan
    Zhang, Xitao
    Yan, Jun
    An, Xiangguang
    Gao, Jie
    Xin, Yue
    Zhou, Jian
    INTERNATIONAL HEART JOURNAL, 2018, 59 (03) : 474 - 481
  • [39] Short-term and long-term neurocognitive outcome in on-pump versus off-pump CABG
    Stroobant, N
    Van Nooten, G
    Van Belleghem, Y
    Vingerhoets, G
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2002, 22 (04) : 559 - 564
  • [40] Efficacy and effectiveness of on-versus off-pump coronary artery bypass grafting: A meta-analysis of mortality and survival
    Filardo, Giovanni
    Hamman, Baron L.
    da Graca, Briget
    Sass, Danielle M.
    Machala, Natalie J.
    Ismail, Safiyah
    Pollock, Benjamin D.
    Collinsworth, Ashley W.
    Grayburn, Paul A.
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2018, 155 (01) : 172 - +