The Influence of On-pump Versus Off-pump Surgery on Short- and Medium-term Postoperative Coronary Flow Reserve After Coronary Artery Bypass Grafting

被引:1
|
作者
Ozulku, Mehmet [1 ]
Caliskan, Mustafa [2 ]
Saba, Tonguc [1 ]
Aksu, Feyza [3 ]
Ciftci, Ozgur [2 ]
Gullu, Hakan [2 ]
Guven, Aytekin [2 ]
Kostek, Osman [3 ]
Caklili, Ozge Telci [3 ]
Aslamaci, Sait [1 ]
Muderrisoglu, Haldun [2 ]
机构
[1] Baskent Univ, Konya Teaching & Med Res Ctr, Dept Cardiovasc Surg, Konya, Turkey
[2] Baskent Univ, Konya Teaching & Med Res Ctr, Dept Cardiol, Hoca Cihan Mah,Saray Cad 1, Selcuklu, Konya, Turkey
[3] Istanbul Medeniyet Univ, Teaching & Med Res Ctr, Dept Internal Med & Cardiol, Istanbul, Turkey
关键词
Off-pump surgery; Coronary flow reserve; hsCRP; Diastolic function; BLOOD-FLOW; DOPPLER-ECHOCARDIOGRAPHY; VELOCITY; ULTRASOUND;
D O I
10.1016/j.hlc.2016.02.012
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Although several clinical trials have compared surgical outcomes between off-pump and on-pump coronary artery bypass grafting (CABG), whether there is a difference in the early- and medium-term postoperative coronary microvascular functions is not fully understood. We compared short- and medium-term coronary microvascular function after off-pump and on-pump CABG. Methods A prospective study of patients undergoing off-pump and on-pump CABG. Eighty-two patients scheduled for CABG were recruited: 38 underwent off-pump surgery and 44 on-pump surgery. Each participant's coronary flow reserve (CFR) and diastolic function were measured with transthoracic Doppler echocardiography six and 12 months after surgery. Results Baseline and hyperaemic diastolic peak flow velocity in the left anterior descending artery were similar in both groups, as was CFR (2.22 +/- 0.66) in the off-pump group compared with (2.13 +/- 0.61) in the on-pump group, (P = 0.54). Coronary flow reserve was significantly and inversely correlated with high sensitivity C-reactive protein concentration (r = -0.416; P < 0.001) and positively correlated with mitral E/ A-wave velocity ratio (r = 0.247; P = 0.02). Stepwise linear regression analysis revealed that only high sensitivity C-reactive protein concentration was independently correlated with CFR (beta = -0.272, P = 0.02). Conclusions Heart-lung bypass technique had no medium-term influence on the coronary microcirculation, despite a possible initial unfavourable effect. Serum hs-CRP concentration was an independent predictor of medium-term coronary microvascular dysfunction.
引用
收藏
页码:1232 / 1239
页数:8
相关论文
共 50 条
  • [1] Risk-adjusted short- and long-term outcomes for on-pump versus off-pump coronary artery bypass surgery
    Williams, ML
    Muhlbaier, LH
    Schroder, JN
    Hata, JA
    Peterson, ED
    Smith, PK
    Landolfo, KP
    Messier, RH
    Davis, RD
    Milano, CA
    CIRCULATION, 2005, 112 (09) : I366 - I370
  • [2] Early-Term Outcomes of Off-Pump versus On-Pump Beating-Heart Coronary Artery Bypass Surgery
    Velioglu, Yusuf
    Isik, Mehmet
    THORACIC AND CARDIOVASCULAR SURGEON, 2019, 67 (07) : 546 - 553
  • [3] Propensity score analysis comparing off-pump versus on-pump coronary artery bypass grafting in older adults
    Shinji Ogawa
    Yoshiharu Mori
    Tumurbaatar Batkhishig
    Toshiyuki Yamada
    Yuhei Saito
    Yukihide Numata
    Shinji Kamiya
    Miki Asano
    Takayuki Saito
    Hisao Suda
    General Thoracic and Cardiovascular Surgery, 2023, 71 : 498 - 504
  • [4] A Comparison of Long-Term Mortality for Off-Pump and On-Pump Coronary Artery Bypass Graft Surgery
    Wu, Chuntao
    Camacho, Fabian T.
    Culliford, Alfred T.
    Gold, Jeffrey P.
    Wechsler, Andrew S.
    Higgins, Robert S. D.
    Lahey, Stephen J.
    Smith, Craig R.
    Jordan, Desmond
    Hannan, Edward L.
    CIRCULATION-CARDIOVASCULAR QUALITY AND OUTCOMES, 2012, 5 (01): : 76 - 84
  • [5] Propensity score analysis comparing off-pump versus on-pump coronary artery bypass grafting in older adults
    Ogawa, Shinji
    Mori, Yoshiharu
    Batkhishig, Tumurbaatar
    Yamada, Toshiyuki
    Saito, Yuhei
    Numata, Yukihide
    Kamiya, Shinji
    Asano, Miki
    Saito, Takayuki
    Suda, Hisao
    GENERAL THORACIC AND CARDIOVASCULAR SURGERY, 2023, 71 (09) : 498 - 504
  • [6] Endothelial Activation After Coronary Artery Bypass Surgery: Comparison Between On-Pump and Off-Pump Techniques
    Vallely, Michael P.
    Bannon, Paul G.
    Bayfield, Matthew S.
    Hughes, Clifford F.
    Kritharides, Len
    HEART LUNG AND CIRCULATION, 2010, 19 (08) : 445 - 452
  • [7] Impact of postoperative hypothermia on outcomes after off-pump coronary artery bypass grafting
    Ntinopoulos, Vasileios
    Papadopoulos, Nestoras
    Haeussler, Achim
    Odavic, Dragan
    Fodor, Patricia
    Dzemali, Omer
    ASIAN CARDIOVASCULAR & THORACIC ANNALS, 2022, 30 (03) : 293 - 299
  • [8] Characteristics of left ventricular and cardiac hemodynamic remodeling after on-pump or off-pump coronary artery bypass grafting
    Mayanskaya, S. D.
    Abzalova, G. F.
    Garaeva, L. A.
    Abdulianov, I., V
    Teplyakov, A. T.
    Berezikova, E. N.
    Grebenkina, I. A.
    BYULLETEN SIBIRSKOY MEDITSINY, 2023, 22 (02): : 88 - 96
  • [9] Mortality risk factors from converting off-pump coronary artery bypass to on-pump coronary artery bypass
    Miao, Na
    Yang, Feng
    Du, Zhongtao
    Jiang, Chunjing
    Hao, Xing
    Wang, Jinhong
    Jiang, Yu
    Yang, Xiaofang
    Xie, Haixiu
    Hou, Xiaotong
    PERFUSION-UK, 2017, 32 (07): : 554 - 560
  • [10] Conversion after off-pump coronary artery bypass grafting: the CORONARY trial experience
    Stevens, Louis-Mathieu
    Noiseux, Nicolas
    Avezum, Alvaro
    Ayapati, Dharma Rakshak
    Chen, Xin
    Lucchese, Fernando Antonio
    Cacheda, Horacio
    Parvathaneni, Sirish
    Ou, Yongning
    Lamy, Andre
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2017, 51 (03) : 539 - 546