High-resolution imaging of magnetisation transfer and nuclear Overhauser effect in the human visual cortex at 7 T

被引:35
|
作者
Mougin, Olivier [1 ]
Clemence, Matthew [2 ]
Peters, Andrew [1 ]
Pitiot, Alain [3 ]
Gowland, Penny [1 ]
机构
[1] Univ Nottingham, Sir Peter Mansfield Magnet Resonance Ctr, Sch Phys & Astron, Nottingham NG7 2RD, England
[2] Philips Ctr, Guildford, Surrey, England
[3] Univ Nottingham, Sch Psychol, Nottingham NG7 2RD, England
基金
英国医学研究理事会;
关键词
high-resolution MRI; magnetisation transfer; nuclear Overhauser enhancement; amide proton transfer; chemical exchange saturation transfer; 7; T; cortex; myeloarchitectonic; EXCHANGE SATURATION-TRANSFER; PULSED STEADY-STATE; CHEMICAL-EXCHANGE; IN-VIVO; TRANSFER CEST; TRANSFER RATIO; MULTIPLE-SCLEROSIS; CEREBRAL-CORTEX; HUMAN BRAIN; MRI;
D O I
10.1002/nbm.2984
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The aim of this study was to optimise a pulse sequence for high-resolution imaging sensitive to the effects of conventional macromolecular magnetisation transfer (MTm) and nuclear Overhauser enhancement (NOE), and to use it to investigate variations in these parameters across the cerebral cortex. A high-spatial-resolution magnetisation transfer-prepared turbo field echo (MT-TFE) sequence was designed to have high sensitivity to MTm and NOE effects, whilst being robust to B-0 and B-1 inhomogeneities, and producing a good point spread function across the cortex. This was achieved by optimising the saturation and imaging components of the sequence using simulations based on the Bloch equations, including exchange and an image simulator. This was used to study variations in these parameters across the cortex. Using the sequence designed to be sensitive to NOE and MTm, a variation in signals corresponding to a variation in MTm and NOE across the cortex, consistent with a reduction in myelination from the white matter surface to the pial surface of the cortex, was observed. In regions in which the stria was visible on T-2*-weighted images, it could also be detected in signals sensitive to MTm and NOE. There was greater variation in signals sensitive to NOE, suggesting that the NOE signal is more sensitive to myelination. A sequence has been designed to image variations in MTm and NOE at high spatial resolution and has been used to investigate variations in contrast in these parameters across the cortex. Copyright (c) 2013 John Wiley & Sons, Ltd.
引用
收藏
页码:1508 / 1517
页数:10
相关论文
共 50 条
  • [21] Clinical High-Resolution 3D-MR Spectroscopic Imaging of the Human Brain at 7 T
    Hingerl, Lukas
    Strasser, Bernhard
    Moser, Philipp
    Hangel, Gilbert
    Motyka, Stanislav
    Heckova, Eva
    Gruber, Stephan
    Trattnig, Siegfried
    Bogner, Wolfgang
    INVESTIGATIVE RADIOLOGY, 2020, 55 (04) : 239 - 248
  • [22] High-resolution echo-planar fMRI of human visual cortex at 3.0 tesla
    Thulborn, KR
    Chang, SY
    Shen, GX
    Voyvodic, JT
    NMR IN BIOMEDICINE, 1997, 10 (4-5) : 183 - 190
  • [23] High-Resolution 7T MRI of the Human Hippocampus In Vivo
    Thomas, Bradley P.
    Welch, E. Brian
    Niederhauser, Blake D.
    Whetsell, William O., Jr.
    Anderson, Adam W.
    Gore, John C.
    Avison, Malcolm J.
    Creasy, Jeffrey L.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 28 (05) : 1266 - 1272
  • [24] FUNCTIONAL-ORGANIZATION OF PRIMATE VISUAL-CORTEX REVEALED BY HIGH-RESOLUTION OPTICAL IMAGING
    TSO, DY
    FROSTIG, RD
    LIEKE, EE
    GRINVALD, A
    SCIENCE, 1990, 249 (4967) : 417 - 420
  • [25] MR imaging of the amide-proton transfer effect and the pH-insensitive nuclear overhauser effect at 9.4 T
    Jin, Tao
    Wang, Ping
    Zong, Xiaopeng
    Kim, Seong-Gi
    MAGNETIC RESONANCE IN MEDICINE, 2013, 69 (03) : 760 - 770
  • [26] ANALYSIS OF HIGH-RESOLUTION NMR SPECTRA BY MEANS OF NUCLEAR OVERHAUSER EFFECT + BY TRANSITORY SELECTIVE IRRADIATION ( TSI ) METHODS
    HOFFMAN, RA
    FORSEN, S
    GESTBLOM, B
    JOURNAL OF CHEMICAL PHYSICS, 1964, 40 (12): : 3734 - &
  • [27] A Specialized Multi-Transmit Head Coil for High Resolution fMRI of the Human Visual Cortex at 7T
    Sengupta, Shubharthi
    Roebroeck, Alard
    Kemper, Valentin G.
    Poser, Benedikt A.
    Zimmermann, Jan
    Goebel, Rainer
    Adriany, Gregor
    PLOS ONE, 2016, 11 (12):
  • [28] Relayed nuclear Overhauser enhancement imaging with magnetization transfer contrast suppression at 3 T
    Huang, Jianpan
    Han, Xiongqi
    Chen, Lin
    Xu, Xiang
    Xu, Jiadi
    Chan, Kannie W. Y.
    MAGNETIC RESONANCE IN MEDICINE, 2021, 85 (01) : 268 - 281
  • [29] 31P MR Spectroscopic Imaging of the Human Prostate at 7 T: T1 Relaxation Times, Nuclear Overhauser Effect, and Spectral Characterization
    Lagemaat, Miriam W.
    Maas, Marnix C.
    Vos, Eline K.
    Bitz, Andreas K.
    Orzada, Stephan
    Weiland, Elisabeth
    van Uden, Mark J.
    Kobus, Thiele
    Heerschap, Arend
    Scheenen, Tom W. J.
    MAGNETIC RESONANCE IN MEDICINE, 2015, 73 (03) : 909 - 920
  • [30] HIGH-RESOLUTION NUCLEAR MAGNETIC-RESONANCE IMAGING OF PIG KNEES AT 4.7 T
    ROBINSON, EM
    MACKENZIE, IS
    FREEMONT, A
    JASANI, MK
    MAGNETIC RESONANCE IMAGING, 1988, 6 (05) : 591 - 594