Experimental investigation and comparative performance analysis of a compact finned-tube heat exchanger uniformly filled with a phase change material for thermal energy storage

被引:56
作者
Amagour, Mohamed El Habib [1 ,2 ]
Rachek, Adil [1 ]
Bennajah, Mounir [1 ]
Touhami, Mohamed Ebn [2 ]
机构
[1] ENSMR, Dept Genie Proc Ind, BP 753 Agdal, Rabat, Morocco
[2] Univ Ibn Tofail, Fac Sci, Lab Ingn Mat & Environm, Modelisat & Applicat, BP 133, Kenitra 14000, Morocco
关键词
Thermal energy storage (TES); Phase change material (PCM); Solar domestic hot water (SDHW); Effectiveness-number of transfer units (epsilon-NTU); Fin efficiency; EFFECTIVENESS-NTU TECHNIQUE; CHANGE MATERIAL PCM; SHELL-AND-TUBE; EXPERIMENTAL VALIDATION; COOLING SYSTEM; WATER TANK; CFD MODEL; FINS; ENHANCEMENT;
D O I
10.1016/j.enconman.2018.03.041
中图分类号
O414.1 [热力学];
学科分类号
摘要
In the present paper, a latent heat storage system using a heat-transfer enhancement technique has been built and tested. The potential of using a natural phase change material of Moroccan provenance for energy storage was studied by experimental analysis. The enhanced heat transfer surface of the compact finned-tube heat exchanger presents geometric complications. Therefore, a new method based on equivalent circular fin efficiency for the calculation of the effective heat transfer surface area was developed and applied to the system under study. In order to carry out the performance analysis for this innovative system, charging and discharging experiments were conducted for different heat transfer fluid flow rates. It was found that increasing the flow rate from 0.2 to 1 l/min divides melting time by 2.5 and solidification time by four. The average effectiveness was calculated for each flow rate and was proven to decrease during charging from 0.95 for a flow rate of 0.2 l/min to 0.63 for 1 l/min. Likewise, increasing flow rate from 0.2 to 1 l/min for discharging process decreases heat exchanger effectiveness from 0.99 to 0.7. The combination of the effectiveness-number of transfer units method with the procedure that was developed to compute the effective heat transfer area lead to derive an empirical correlation. This equation was used to compare the finned-tube compact storage system with other heat and cold storage units. The comparison showed that the present system displayed satisfactory results. The second use of the correlation was to design, through a case study, a heat storage system suitable for solar domestic hot water production in a residential building.
引用
收藏
页码:137 / 151
页数:15
相关论文
共 43 条
[1]   Approximate analytic temperature distribution and efficiency for annular fins of uniform thickness [J].
Acosta-Iborra, Antonio ;
Campo, Antonio .
INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2009, 48 (04) :773-780
[2]   Experimental determination of the heat transfer and cold storage characteristics of a microencapsulated phase change material in a horizontal tank [J].
Allouche, Yosr ;
Varga, Szabolcs ;
Bouden, Chiheb ;
Oliveira, Armando C. .
ENERGY CONVERSION AND MANAGEMENT, 2015, 94 :275-285
[3]   Thermal energy storage materials and systems for solar energy applications [J].
Alva, Guruprasad ;
Liu, Lingkun ;
Huang, Xiang ;
Fang, Guiyin .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2017, 68 :693-706
[4]   Materials used as PCM in thermal energy storage in buildings: A review [J].
Cabeza, L. F. ;
Castell, A. ;
Barreneche, C. ;
de Gracia, A. ;
Fernandez, A. I. .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2011, 15 (03) :1675-1695
[5]   Thermal performance of an integrated collector storage solar water heater (ICSSWH) with phase change materials (PCM) [J].
Chaabane, Monia ;
Mhiri, Hatem ;
Bournot, Philippe .
ENERGY CONVERSION AND MANAGEMENT, 2014, 78 :897-903
[6]   Experimental investigation on PCM cold storage integrated with ejector cooling system [J].
Chen, Xiangjie ;
Worall, Mark ;
Omer, Siddig ;
Su, Yuehong ;
Riffat, Saffa .
APPLIED THERMAL ENGINEERING, 2014, 63 (01) :419-427
[7]   Melting and solidification of PCM enhanced by radial conductive fins and nanoparticles in cylindrical annulus [J].
Darzi, A. Ali Rabienataj ;
Jourabian, Mahmoud ;
Farhadi, Mousa .
ENERGY CONVERSION AND MANAGEMENT, 2016, 118 :253-263
[8]  
Doebelin EO, 1990, MEASUREMENT SYSTEMS, P984
[9]   Adjustment of thermal behavior by changing the shape of PCM inclusions in concrete blocks [J].
Erlbeck, L. ;
Schreiner, P. ;
Schlachter, K. ;
Doernhofer, P. ;
Fasel, F. ;
Methner, F. -J. ;
Raedle, M. .
ENERGY CONVERSION AND MANAGEMENT, 2018, 158 :256-265
[10]   A numerical study, on the usage of phase change material (PCM) to prolong compressor off period in a beverage cooler [J].
Ezan, Mehmet Akif ;
Doganay, Esra Ozcan ;
Yavuz, Fazil Erinc ;
Tavman, Ismail Hakki .
ENERGY CONVERSION AND MANAGEMENT, 2017, 142 :95-106