Prognostic impact of inappropriate defibrillator shocks in a population cohort

被引:19
|
作者
Deyell, Marc William [1 ]
Qi, Anzhen [1 ]
Chakrabarti, Santabhanu [1 ]
Yeung-Lai-Wah, John Ah-Fan [1 ]
Tung, Stanley [1 ]
Khoo, Clarence [1 ]
Bennett, Mathew T. [1 ]
Qian, Hong [2 ]
Kerr, Charles R. [1 ]
机构
[1] Univ British Columbia, Heart Rhythm Serv, Div Cardiol, Vancouver, BC V6E 1M7, Canada
[2] Univ British Columbia, Ctr Hlth Evaluat & Outcome Sci, Vancouver, BC V6E 1M7, Canada
关键词
Arrhythmias; IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR; ASSOCIATION TASK-FORCE; CHRONIC HEART-FAILURE; CARDIAC-RESYNCHRONIZATION; ANTIARRHYTHMIA DEVICES; MYOCARDIAL-INFARCTION; PRACTICE GUIDELINES; THERAPY; TRIAL; ARRHYTHMIAS;
D O I
10.1136/heartjnl-2012-303407
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background There is a relative paucity of data linking inappropriate implantable cardioverter-defibrillator (ICD) shocks to adverse clinical outcomes. Objective To examine the association between inappropriate ICD shocks and mortality or heart transplantation in a large population cohort. Design, setting, patients A cohort study which included all subjects who underwent ICD implantation between 1998 and 2008 and were followed up at our institution. Main outcome measures Multivariable Cox regression analyses were conducted to investigate the effect of inappropriate shocks on the risk of death and heart transplantation. Appropriate and inappropriate ICD therapies were modelled as time-dependent covariates. Results A total of 1698 patients were included. During a median follow-up of 30months, there were 246 (14.5%) deaths and 42 (2.5%) heart transplants. The incidence of inappropriate shocks was 10% at 1year and 14% at 2years. In the adjusted model, inappropriate shocks were not associated with death or transplantation (HR=0.97, 95% CI 0.70 to 1.36, p value=0.873). In contrast, appropriate shocks were associated with adverse outcomes (HR=3.11, 95% CI 2.41 to 4.02, p value<0.001). The lack of association between inappropriate shocks and outcomes persisted for those with severely impaired left ventricular function (ejection fraction <30%) and for those receiving multiple inappropriate treatments. Conclusions In this study, we observed no association between inappropriate ICD shocks and increased mortality or heart transplantation, even among those with severely impaired cardiac function. These findings question whether inappropriate ICD shocks lead to adverse outcomes.
引用
收藏
页码:1250 / 1255
页数:6
相关论文
共 50 条
  • [1] Inappropriate defibrillator shocks and mortality
    Liew, Reginald
    HEART, 2013, 99 (17) : 1223 - 1224
  • [2] Inappropriate Implantable Defibrillator Shocks
    Raitt, Merritt H.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 62 (15) : 1351 - 1352
  • [3] Incidence, mechanisms, and clinical impact of inappropriate shocks in patients with a subcutaneous defibrillator
    Rudic, Boris
    Tueluemen, Erol
    Fastenrath, Fabian
    Roeger, Susanne
    Goranova, Diana
    Akin, Ibrahim
    Borggrefe, Martin
    Kuschyk, Juergen
    EUROPACE, 2020, 22 (05): : 761 - 768
  • [4] The Impact of Inappropriate Implantable Cardiac Defibrillator Shocks on Cardiovascular Morbidity and Mortality
    Mehta, Nishaki K.
    Taylor, Montoya
    Kalbfleisch, Steven
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2016, 39 (08): : 858 - 862
  • [5] Prevalence and prognostic impact of inappropriate defibrillator shocks in patients with ICD due to primary or secondary prevention of sudden cardiac death
    Kleemann, T.
    Strauss, M.
    Dyck, N.
    Becker, T.
    Seidl, K.
    EUROPEAN HEART JOURNAL, 2010, 31 : 928 - 928
  • [6] Biventricular implantable cardioverter defibrillator and inappropriate shocks
    Srivathsan, K
    Bazzell, JL
    Lee, RW
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2003, 14 (01) : 88 - 89
  • [7] Inappropriate Implantable Cardioverter-Defibrillator Shocks Incidence, Predictors, and Impact on Mortality
    van Rees, Johannes B.
    Borleffs, C. Jan Willem
    de Bie, Mihaly K.
    Stijnen, Theo
    van Erven, Lieselot
    Bax, Jeroen J.
    Schalij, Martin J.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 57 (05) : 556 - 562
  • [8] Inappropriate shocks in a patient treated with a cardioverter defibrillator
    Hutse, W
    Tavernier, R
    Jordaens, L
    HEART, 1997, 77 (04) : 386 - 387
  • [9] Appropriate and inappropriate defibrillator shocks: predictors and impact on prognosis in a cohort of patients implanted for secondary sudden cardiac death prevention
    Castagno, D.
    Golzio, P. G.
    Budano, C.
    Bissolino, A.
    Riccardi, R.
    Pozzi, R.
    Marcolongo, M.
    Scaglione, M.
    Marra, S.
    Gaita, F.
    EUROPEAN HEART JOURNAL, 2013, 34 : 267 - 267
  • [10] Appropriate and inappropriate defibrillator shocks: predictors and impact on prognosis in a cohort of patients implanted for primary sudden cardiac death prevention
    Castagno, D.
    Golzio, P. G.
    Troiano, F.
    Bissolino, A.
    Anselmino, M.
    Budano, C.
    Riccardi, R.
    Pozzi, R.
    Scaglione, M.
    Gaita, F.
    EUROPEAN HEART JOURNAL, 2014, 35 : 765 - 765