Application of 640-slice CT wide-detector volume scan in low-dose CT pulmonary angiography

被引:4
作者
Lu, Fengqi [1 ]
Gao, Yu [1 ]
Kong, Que [1 ]
Qiao, Peng [1 ]
Shao, Min [1 ]
Xie, Min [1 ]
机构
[1] Nanjing Med Univ, Dept Radiol, Wuxi Hosp 2, Wuxi City, Peoples R China
关键词
640-slice CT; wide-detector volume scan; low-dose; CT pulmonary angiography; IMAGE QUALITY; EMBOLISM; DIAGNOSIS; RECONSTRUCTION; RADIATION; IMPACT;
D O I
10.3233/XST-180427
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
BACKGROUND: Computed tomography (CT) pulmonary angiography (CTPA) examination has been frequently applied in detecting suspected pulmonary embolism (PE). How to reduce radiation dose to patients is also of concern. OBJECTIVE: To assess the value of using 640-slice CT wide-detector volume scan with adaptive statistical iterative reconstruction (ASIR) algorithm in low-dose CTPA. METHODS: Fifty-eight patients who performed with CTPA were divided into two groups randomly. In the first experimental group (n = 30), ASIR combined with volume scan were performed on the patients, while in the second conventional group (n = 28), patients received ASIR combined with conventional spiral scan. General data including age and body mass index, image quality, pulmonary arterial phase, and radiation dose were analyzed by t test in the two groups. RESULTS: In both groups, all images revealed the 5-order or higher pulmonary arterial branches and fully met the needs for clinical diagnosis. There was no statistical difference in general data between the two groups. In terms of pulmonary phase accuracy, compared with the conventional group, images at pulmonary arterial phase could be captured more accurately in the experimental group. CTDI in the experimental group decreased by 30% compared with that in the conventional group. The actual radiation dose in the experimental group was 1.5 mSv, which is reduced by 53% compared to that in the conventional group. CONCLUSIONS: Compared with the conventional spiral scan, using 640-slice CT volume scan with ASIR in CTPA is more accurate in scanning phase and has lower radiation dose. There is no significant difference in image quality between the two groups.
引用
收藏
页码:197 / 205
页数:9
相关论文
共 17 条
  • [1] State-of-the-Art Pulmonary CT Angiography for Acute Pulmonary Embolism
    Albrecht, Moritz H.
    Bickford, Matthew W.
    Nance, John W., Jr.
    Zhang, Longjiang
    De Cecco, Carlo N.
    Wichmann, Julian L.
    Vogl, Thomas J.
    Schoepf, U. Joseph
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2017, 208 (03) : 495 - 504
  • [2] State of the Art: Iterative CT Reconstruction Techniques
    Geyer, Lucas L.
    Schoepf, U. Joseph
    Meinel, Felix G.
    Nance, John W., Jr.
    Bastarrika, Gorka
    Leipsic, Jonathon A.
    Paul, Narinder S.
    Rengo, Marco
    Laghi, Andrea
    De Cecco, Carlo N.
    [J]. RADIOLOGY, 2015, 276 (02) : 338 - 356
  • [3] Impact of Tube Current-Time and Tube Voltage Reduction in 64-Detector-row Computed Tomography Pulmonary Angiography for Pulmonary Embolism in a Porcine Model
    Henes, Frank Oliver Gerhard
    Groth, Michael
    Begemann, Philipp G. C.
    Bley, Thorsten
    Adam, Gerhard
    Regier, Marc
    [J]. JOURNAL OF THORACIC IMAGING, 2012, 27 (02) : 113 - 120
  • [4] Overdiagnosis of Pulmonary Embolism by Pulmonary CT Angiography
    Hutchinson, Barry Donald
    Navin, Patrick
    Marom, Edith M.
    Truong, Mylene T.
    Bruzzi, John F.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 205 (02) : 271 - 277
  • [5] How I Do It: Managing Radiation Dose in CT
    Mayo-Smith, William W.
    Hara, Amy K.
    Mahesh, Mahadevappa
    Sahani, Dushyant V.
    Pavlicek, William
    [J]. RADIOLOGY, 2014, 273 (03) : 657 - 672
  • [6] High pitch, low voltage dual source CT pulmonary angiography: assessment of image quality and diagnostic acceptability with hybrid iterative reconstruction
    McLaughlin, Patrick D.
    Homiedan, T. Liang M.
    Louis, L. J.
    O'Connell, T. W.
    Krzymyk, Karl
    Nicolaou, S.
    Mayo, J. R.
    [J]. EMERGENCY RADIOLOGY, 2015, 22 (02) : 117 - 123
  • [7] Impact of iterative reconstruction on the diagnosis of acute pulmonary embolism (PE) on reduced-dose chest CT angiograms
    Pontana, Franois
    Henry, Simon
    Duhamel, Alain
    Faivre, Jean-Baptiste
    Tacelli, Nunzia
    Pagniez, Julien
    Remy, Jacques
    Remy-Jardin, Martine
    [J]. EUROPEAN RADIOLOGY, 2015, 25 (04) : 1182 - 1189
  • [8] Management of suspected acute pulmonary embolism in the era of CT angiography: A statement from the Fleischner Society
    Remy-Jardin, Martine
    Pistolesi, Massimo
    Goodman, Lawrence R.
    Gefter, Warren B.
    Gottschalk, Alexander
    Mayo, John R.
    Sostman, H. Dirk
    [J]. RADIOLOGY, 2007, 245 (02) : 315 - 329
  • [9] Diagnosis of pulmonary embolism with spiral CT: Comparison with pulmonary angiography and scintigraphy
    RemyJardin, M
    Remy, J
    Deschildre, F
    Artaud, D
    Beregi, JP
    HosseinFoucher, C
    Marchandise, X
    Duhamel, A
    [J]. RADIOLOGY, 1996, 200 (03) : 699 - 706
  • [10] CENTRAL PULMONARY THROMBOEMBOLISM - DIAGNOSIS WITH SPIRAL VOLUMETRIC CT WITH THE SINGLE-BREATH-HOLD TECHNIQUE - COMPARISON WITH PULMONARY ANGIOGRAPHY