Functional hemodynamic monitoring

被引:190
作者
Pinsky, MR [1 ]
Payen, D
机构
[1] Univ Pittsburgh, Med Ctr, Dept Crit Care Med, Pittsburgh, PA 15260 USA
[2] Univ Paris 07, Lariboisiere Hosp, Dept Anesthesiol & Crit Care Med, Paris, France
基金
美国国家卫生研究院;
关键词
D O I
10.1186/cc3927
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Hemodynamic monitoring is a central component of intensive care. Patterns of hemodynamic variables often suggest cardiogenic, hypovolemic, obstructive, or distributive ( septic) etiologies to cardiovascular insufficiency, thus defining the specific treatments required. Monitoring increases in invasiveness, as required, as the risk for cardiovascular instability-induced morbidity increases because of the need to define more accurately the diagnosis and monitor the response to therapy. Monitoring is also context specific: requirements during cardiac surgery will be different from those in the intensive care unit or emergency department. Solitary hemodynamic values are useful as threshold monitors ( e. g. hypotension is always pathological, central venous pressure is only elevated in disease). Some hemodynamic values can only be interpreted relative to metabolic demand, whereas others have multiple meanings. Functional hemodynamic monitoring implies a therapeutic application, independent of diagnosis such as a therapeutic trial of fluid challenge to assess preload responsiveness. Newer methods for assessing preload responsiveness include monitoring changes in central venous pressure during spontaneous inspiration, and variations in arterial pulse pressure, systolic pressure, and aortic flow variation in response to vena caval collapse during positive pressure ventilation or passive leg raising. Defining preload responsiveness using these functional measures, coupled to treatment protocols, can improve outcome from critical illness. Potentially, as these and newer, less invasive hemodynamic measures are validated, they could be incorporated into such protocolized care in a cost-effective manner.
引用
收藏
页码:566 / 572
页数:7
相关论文
共 55 条
[1]   Respiratory changes in inferior vena cava diameter are helpful in predicting fluid responsiveness in ventilated septic patients [J].
Barbier, C ;
Loubières, Y ;
Schmit, C ;
Hayon, J ;
Ricôme, JL ;
Jardin, FO ;
Vieillard-Baron, A .
INTENSIVE CARE MEDICINE, 2004, 30 (09) :1740-1746
[2]   HEMODYNAMIC AND OXYGEN-TRANSPORT PATTERNS IN SURVIVING AND NONSURVIVING POSTOPERATIVE-PATIENTS [J].
BLAND, RD ;
SHOEMAKER, WC ;
ABRAHAM, E ;
COBO, JC .
CRITICAL CARE MEDICINE, 1985, 13 (02) :85-90
[3]   Changes in BP induced by passive leg raising predict response to fluid loading in critically ill patients [J].
Boulain, T ;
Achard, JM ;
Teboul, JL ;
Richard, C ;
Perrotin, D ;
Ginies, G .
CHEST, 2002, 121 (04) :1245-1252
[4]   Accuracy of oscillometric blood pressure measurement according to the relation between cuff size and upper-arm circumference in critically ill patients [J].
Bur, A ;
Hirschl, MM ;
Herkner, H ;
Oschatz, E ;
Kofler, J ;
Woisetschläger, C ;
Laggner, AN .
CRITICAL CARE MEDICINE, 2000, 28 (02) :371-376
[5]   Opening the microcirculation: can vasodilators be useful in sepsis? [J].
Buwalda, M ;
Ince, C .
INTENSIVE CARE MEDICINE, 2002, 28 (09) :1208-1217
[6]   Noninvasive cardiac output monitoring by aortic blood flow determination:: Evaluation of the Sometec Dynemo-3000 system [J].
Cariou, A ;
Monchi, M ;
Joly, LM ;
Bellenfant, F ;
Claessens, YE ;
Thébert, D ;
Brunet, F ;
Dhainaut, JF .
CRITICAL CARE MEDICINE, 1998, 26 (12) :2066-2072
[7]   A dobutamine test can disclose hepatosplanchnic hypoperfusion in septic patients [J].
Creteur, J ;
De Backer, D ;
Vincent, JL .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1999, 160 (03) :839-845
[8]   Surviving Sepsis Campaign guidelines for management of severe sepsis and septic shock [J].
Dellinger, RP ;
Carlet, JM ;
Masur, H ;
Gerlach, H ;
Calandra, T ;
Cohen, J ;
Gea-Banacloche, J ;
Keh, D ;
Marshall, JC ;
Parker, MM ;
Ramsay, G ;
Zimmerman, JL ;
Vincent, JL ;
Levy, MM .
CRITICAL CARE MEDICINE, 2004, 32 (03) :858-873
[9]   Respiratory changes in aortic blood velocity as an indicator of fluid responsiveness in ventilated patients with septic shock [J].
Feissel, M ;
Michard, F ;
Mangin, I ;
Ruyer, O ;
Faller, JP ;
Teboul, JL .
CHEST, 2001, 119 (03) :867-873
[10]   Pre-operative optimisation employing dopexamine or adrenaline for patients undergoing major elective surgery: a cost-effectiveness analysis [J].
Fenwick, E ;
Wilson, J ;
Sculpher, M ;
Claxton, K .
INTENSIVE CARE MEDICINE, 2002, 28 (05) :599-608