Vertical temperature profiles and borehole resistance in a U-tube borehole heat exchanger

被引:48
|
作者
Beier, Richard A. [1 ]
Acuna, Jose [2 ]
Mogensen, Palne [3 ]
Palm, Bjorn [2 ]
机构
[1] Oklahoma State Univ, Dept Mech Engn Technol, Stillwater, OK 74078 USA
[2] Royal Inst Technol KTH, Dept Energy Technol, S-10044 Stockholm, Sweden
[3] Palne Mogensen AB, S-18267 Djursholm, Sweden
关键词
Ground-source heat pump; Borehole heat transfer; Ground thermal conductivity; Thermal response test; Borehole thermal resistance;
D O I
10.1016/j.geothermics.2012.06.001
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The design of ground source heat pump systems requires values for the ground thermal conductivity and the borehole thermal resistance. In situ thermal response tests (TRT) are often performed on vertical boreholes to determine these parameters. Most TRT analysis methods apply the mean of the inlet and outlet temperatures of the circulating fluid along the entire borehole length. This assumption is convenient but not rigorous. To provide a more general approach, this paper develops an analytical model of the vertical temperature profile in the borehole during the late-time period of the in situ test. The model also includes the vertical temperature profile of the undisturbed ground. The model is verified with distributed temperature measurements along a vertical borehole using fiber optic cables inside a U-tube for the circulating fluid. The borehole thermal resistance is calculated without the need for the mean temperature approximation. In the studied borehole, the mean temperature approximation overestimates the borehole resistance by more than 20%. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:23 / 32
页数:10
相关论文
共 50 条
  • [1] Borehole thermal resistance of U-tube borehole heat exchanger
    Abuel-Naga, H. M.
    Al-Chalabi, R. R.
    GEOTECHNIQUE LETTERS, 2016, 6 (04) : 250 - 255
  • [2] Transient heat transfer in a U-tube borehole heat exchanger
    Beier, Richard A.
    APPLIED THERMAL ENGINEERING, 2014, 62 (01) : 256 - 266
  • [3] EFFECTIVE BOREHOLE THERMAL RESISTANCE OF A SINGLE U-TUBE GROUND HEAT EXCHANGER
    Liao, Quan
    Zhou, Chao
    Cui, Wenzhi
    Jen, Tien-Chien
    NUMERICAL HEAT TRANSFER PART A-APPLICATIONS, 2012, 62 (03) : 197 - 210
  • [4] Thermal performance investigation of borehole heat exchanger with different U-tube diameter and borehole parameters
    Li, Yang
    An, Qingsong
    Liu, Liangxu
    Zhao, Jun
    INTERNATIONAL CONFERENCE ON APPLIED ENERGY, ICAE2014, 2014, 61 : 2690 - 2694
  • [5] Borehole resistance and vertical temperature profiles in coaxial borehole heat exchangers
    Beier, Richard A.
    Acuna, Jose
    Mogensen, Palne
    Palm, Bjorn
    APPLIED ENERGY, 2013, 102 : 665 - 675
  • [6] Effects of the temperature distribution on the thermal resistance of double u-tube borehole heat exchangers
    Zanchini, Enzo
    Jahanbin, Aminhossein
    GEOTHERMICS, 2018, 71 : 46 - 54
  • [7] Thermal performance and economic evaluation of double U-tube borehole heat exchanger with three different borehole diameters
    Luo, Jin
    Rohn, Joachim
    Bayer, Manfred
    Priess, Anna
    ENERGY AND BUILDINGS, 2013, 67 : 217 - 224
  • [8] Transient heat transfer performance of a vertical double U-tube borehole heat exchanger under different operation conditions
    Zhu, Li
    Chen, Sarula
    Yang, Yang
    Sun, Yong
    RENEWABLE ENERGY, 2019, 131 : 494 - 505
  • [9] Short-term fluid temperature variations in either a coaxial or U-tube borehole heat exchanger
    Gordon, David
    Bolisetti, Tirupati
    Ting, David S. -K.
    Reitsma, Stanley
    GEOTHERMICS, 2017, 67 : 29 - 39
  • [10] Heat transfer simulation, analysis and performance study of single U-tube borehole heat exchanger
    Kerme, Esa Dube
    Fung, Alan S.